Goodman Mfg A/GPG13 M operating instructions PG136090M41A* Rise Range 45

Page 22

BLOWER PERFORMANCE DATA - SINGLE PHASE

*PG136090M41A* - Rise Range: 45° - 75°

Unit

 

T1 HEATING SPEED

 

 

T2 HEATING SPEED

 

 

T3 HEATING SPEED

 

Static

CFM

WATTS

AMPS

RISE

CFM

WATTS

AMPS

RISE

CFM

WATTS

AMPS

RISE

0.1

1,125

162

1.44

61

1,466

315

2.67

47

1,780

496

3.33

NR

0.2

1,049

168

1.53

65

1,384

322

2.74

50

1,730

506

3.89

NR

0.3

1,000

178

1.60

69

1,347

329

2.78

51

1,664

520

4.01

NR

0.4

910

184

1.64

75

1,291

341

2.83

53

1,608

526

4.03

NR

0.5

857

197

1.75

NR

1,237

350

2.90

55

1,568

532

4.12

NR

0.6

809

201

1.83

NR

1,185

362

3.05

58

1,515

546

4.14

45

0.7

739

207

1.86

NR

1,134

369

3.09

60

1,477

552

4.18

46

0.8

703

218

1.96

NR

1,087

382

3.21

63

1,422

562

4.23

48

Unit

T4 COOLING SPEED

T5 COOLING SPEED

Static

CFM

WATTS

AMPS

CFM

WATTS

AMPS

0.1

1,942

649

4.83

2,067

792

5.81

0.2

1,883

657

4.87

2,030

811

5.85

0.3

1,859

670

4.96

1,982

814

5.88

0.4

1,827

675

4.97

1,909

808

5.86

0.5

1,749

683

4.99

1,842

798

5.85

0.6

1,706

693

5.10

1,789

772

5.65

0.7

1,655

703

5.12

1,703

763

5.58

0.8

1,588

705

5.11

1,618

732

5.29

*PG1360115M41A* - Rise Range: 45° - 75°

Unit

 

T1 HEATING SPEED

 

 

T2 HEATING SPEED

 

 

T3 HEATING SPEED

 

Static

CFM

WATTS

AMPS

RISE

CFM

WATTS

AMPS

RISE

CFM

WATTS

AMPS

RISE

0.1

1,125

162

1.44

NR

1,466

315

2.67

58

1,780

496

3.33

48

0.2

1,049

168

1.53

NR

1,384

322

2.74

62

1,730

506

3.89

49

0.3

1,000

178

1.60

NR

1,347

329

2.78

63

1,664

520

4.01

51

0.4

910

184

1.64

NR

1,291

341

2.83

66

1,608

526

4.03

53

0.5

857

197

1.75

NR

1,237

350

2.90

69

1,568

532

4.12

54

0.6

809

201

1.83

NR

1,185

362

3.05

72

1,515

546

4.14

56

0.7

739

207

1.86

NR

1,134

369

3.09

NR

1,477

552

4.18

58

0.8

703

218

1.96

NR

1,087

382

3.21

NR

1,422

562

4.23

60

Unit

T4 COOLING SPEED

T5 COOLING SPEED

Static

CFM

WATTS

AMPS

CFM

WATTS

AMPS

0.1

1,942

649

4.83

2,067

792

5.81

0.2

1,883

657

4.87

2,030

811

5.85

0.3

1,859

670

4.96

1,982

814

5.88

0.4

1,827

675

4.97

1,909

808

5.86

0.5

1,749

683

4.99

1,842

798

5.85

0.6

1,706

693

5.10

1,789

772

5.65

0.7

1,655

703

5.12

1,703

763

5.58

0.8

1,588

705

5.11

1,618

732

5.29

 

 

 

 

*PG1360140M41A* - Rise Range: 45° - 75°

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit

 

T1 HEATING SPEED

 

 

T2 HEATING SPEED

 

 

T3 HEATING SPEED

 

Static

CFM

WATTS

AMPS

RISE

CFM

WATTS

AMPS

RISE

CFM

WATTS

AMPS

RISE

0.1

1,125

162

1.44

NR

1,466

315

2.67

71

1,780

496

3.33

59

0.2

1,049

168

1.53

NR

1,384

322

2.74

NR

1,730

506

3.89

60

0.3

1,000

178

1.60

NR

1,347

329

2.78

NR

1,664

520

4.01

63

0.4

910

184

1.64

NR

1,291

341

2.83

NR

1,608

526

4.03

65

0.5

857

197

1.75

NR

1,237

350

2.90

NR

1,568

532

4.12

67

0.6

809

201

1.83

NR

1,185

362

3.05

NR

1,515

546

4.14

69

0.7

739

207

1.86

NR

1,134

369

3.09

NR

1,477

552

4.18

71

0.8

703

218

1.96

NR

1,087

382

3.21

NR

1,422

562

4.23

74

Unit

T4 COOLING SPEED

T5 COOLING SPEED

Static

CFM

WATTS

AMPS

CFM

WATTS

AMPS

0.1

1,942

649

4.83

2,067

792

5.81

0.2

1,883

657

4.87

2,030

811

5.85

0.3

1,859

670

4.96

1,982

814

5.88

0.4

1,827

675

4.97

1,909

808

5.86

0.5

1,749

683

4.99

1,842

798

5.85

0.6

1,706

693

5.10

1,789

772

5.65

0.7

1,655

703

5.12

1,703

763

5.58

0.8

1,588

705

5.11

1,618

732

5.29

NR = Heating Temperature Rise Not Recommended. NOTE: The shaded area indicates ranges in excess of maximum external static pressure allowable when heating. For satisfactory operation, external static pressure should not exceed 0.5" w.c.

22

Image 22
Contents GPG13 M Series W/R410A Ansi Z21.47CSA-2.3 Central FurnacesPropane Gas Installations Replacement PartsSafety Instructions Electrical WiringReplacement Parts Safety InstructionsUnit Location Carbon Monoxide Poisoning HazardRoof Curb Installation Outside Slab InstallationRooftop Installation General InformationGAS Piping Rigging DetailsRigging Natural Gas Connection Proper Piping PracticeTypical Propane Gas Piping Electrical WiringPropane Gas Pipe Sizing Low Voltage Wiring Typical Electrical Wiring Unit VoltageFilter Installation Typical Thermostat and Unit 24 V Wiring HookupDuct Cover Installation Down Discharge Applications Circulating AIR and FiltersCondensate Drain STARTUP, ADJUSTMENTS, and ChecksVenting Normal Sequences of OperationWhite-Rodgers 36G22 Secondary Limit Control Pre-Operation ChecksWhite-Rodgers Model 36G22 Honeywell Model VR8215 Single-StageGas Input Natural Gas Only Check Temperature Rise CheckBlower Speed Adjustments Main Burner Flame CheckTroubleshooting Maintenance Flame Sensor Manifold AssemblyBurner Flame Accessories and Functional Parts Functional Parts ListBlower Performance Data Single Phase CFM Watts Amps RiseRemoved AA & Used a T1 Heating Speed T2 Heating Speed T3 Heating Speed CFM Watts AmpsPG136090M41A* Rise Range 45 Blower Performance Data Heating Speeds Three Phase RPM CFMCFM Watts RPM Amps Heating Timing Chart Appendix Unit Dimensions PG1324,30,36,421** Wiring Diagram INSTALLER/SERVICEMAN THC-FIELD Wiring YL RD BL BL BLINSTALLER/SERVICEMAN Thermostat Field Wiring VMRGPG13363** Wiring Diagram INSTALLER/SERVICEMAN EconomizerGPG1348,603** Wiring Diagram BL BL BL RD RDOption Minimum Clearances Recommended Filter SizesThat’s why we know. . .There’s No Better Quality Quality Makes the Difference

A/GPG13 M specifications

Goodman Manufacturing is known for producing high-quality HVAC systems, and one of its standout offerings is the Goodman A/GPG13 M series. This air conditioning and heating unit delivers exceptional performance, reliability, and efficiency, making it a preferred choice for residential settings.

The Goodman A/GPG13 M is specifically designed to provide homeowners with an efficient and affordable solution for climate control. One of its main features is the energy-efficient compressor, which operates with a SEER rating of up to 13, ensuring reduced electricity consumption while effectively cooling your living space. This efficiency not only minimizes utility bills but also helps to lower your carbon footprint.

Another standout characteristic of the Goodman A/GPG13 M is its durable construction. The unit is engineered with a heavy-gauge, galvanized steel cabinet that has a polyester finish, providing protection against rust and corrosion. This durability ensures that the system can withstand the elements and lasting performance even in challenging climates.

The Goodman A/GPG13 M series also boasts advanced technology to enhance comfort levels in any home. The unit is equipped with a two-stage cooling system that can adjust to varying temperature demands, ensuring that your living space remains comfortable throughout the hot summer months. Additionally, the unit includes a multi-speed blower for more even air distribution, enhancing overall comfort.

Furthermore, the Goodman A/GPG13 M complies with rigorous environmental standards. It uses R-410A refrigerant, which is more environmentally friendly than older refrigerants like R-22, making it an excellent choice for eco-conscious consumers.

Installation of the Goodman A/GPG13 M is made easier with its lightweight design and user-friendly features, allowing HVAC professionals to install the system efficiently. The unit is backed by a comprehensive warranty, reflecting Goodman Manufacturing’s commitment to quality and customer satisfaction.

In summary, the Goodman A/GPG13 M series showcases an impressive combination of energy efficiency, durable construction, advanced technology, and eco-friendly refrigerant choices. It represents an ideal option for homeowners who seek a reliable HVAC solution that delivers consistent comfort while maintaining an eye on energy consumption and environmental impact.