REGULAR INSPECTION

PLEASE CHECK THE FOLLOWING POINTS EVERY EITHER HALF YEARLY OR YEARLY. CONTACT YOUR SALES AGENT SHOULD YOU NEED ANY HELP.

 

 

 

 

 

 

Is the plug plugged into the socket firmly?

 

 

 

 

 

WARNING

If the earth line is disconnected or faulty, unit failure or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

electric shock hazard may result.

 

 

 

 

 

 

If the plug have dust or dirt, please clean it before plug in.

 

 

 

 

 

 

 

 

 

 

 

 

 

Is the unit’s earth line connected correctly?

 

 

 

 

 

WARNING

Please make sure earth line is connected correctly.

 

 

 

 

 

If the earth line is disconnected or faulty, it may result in

 

 

 

 

 

 

malfunction or electric shock.

 

 

 

 

 

 

 

 

 

 

 

 

 

Is the mounting frame stable?

 

 

 

 

 

WARNING

Check to see if the mounting frame has rusted excessively

 

 

 

 

 

or if the outdoor unit has tilted or become unstable.

 

 

 

 

 

 

If the outdoor unit collapsed or fell, it could cause injury.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INSPECTION AND MAINTENANCE

Air conditioner is designed to perform automatic filter cleaning to maintain the interior of air conditioner clean. However, the interior of air conditioner may get dirty and the air conditioning performance may be lowered after air conditioner is used for a few seasons.

CAUTION

Beside maintenance, please perform inspection as well

Dust deposited inside the indoor unit may block the drainage path of dehumidified water and could result in water dripping.

Maintenance inspection is recommended in addition to ordinary cleaning.

Request your sales agent for maintenance inspection

Maintenance inspection requires technical expertise. Use of commercially available cleaning agent may cause crack on resin part and clogging of drainage path, which could result in water dripping and electrical shock.

Consult your sales agent for inspection and maintenance.

ENGLISH

– 45 –

Image 45
Contents RAS-SX10HAK / RAC-SX10HAK RAS-SX13HAK / RAC-SX13HAK РУССКИЙ ∂ÏÏËÓÈο PORTUGUÊS SPANISH ITALIANO FRANÇAIS DEUTSCH ENGLISHINDOOR UNIT OUTDOOR UNIT RAS-SX10HAK RAS-SX13HAKPRECAUTIONS DURING SHIFTING OR MAINTENANCE PRECAUTIONS DURING INSTALLATIONPRECAUTIONS DURING OPERATION SAFETY PRECAUTIONENGLISH INDOOR UNIT NAMES AND FUNCTIONS OF EACH PARTOUTDOOR UNIT ABOUT OUTDOOR UNITHow to Attach the Nano Titanium Air Cleaning Mesh Preparation INDOOR UNIT CONTROL PANEL / CLEANING UNITNAMES AND FUNCTIONS OF EACH PART continued REMOTE CONTROLLERBUTTONS TO START OPERATIONSPOWERFULL Button FUNCTION SELECTORINSTALLING ANTI-MOLD WASABI CASSETTE 2 Install the anti-mold wasabi cassette1 Open the front panel Close the front panel 1 Make sure the power plug is firmly plugged into the power outlet FILTER CLEANING UNIT OPERATION CHECK2 Performing operation check after the power is turned on Perform the filter cleaning unit operation checkInstall the batteries PREPARE THE REMOTE CONTROLLEROpen the cover and press the RESET ABOUT ADDRESS SELECTOR SWITCHPREPARE THE REMOTE CONTROLLER continued Ampere setting Standard/Save can be selectedWHEN OPERATING THE REMOTE CONTROLLER AUTOMATIC OPERATION Adjust the room temperatureSTOP AUTOMATIC OPERATIONDEHUMIDIFYING OPERATION HEATING OPERATIONCOOLING OPERATION DEHUMIDIFYING OPERATION continuedDRY COOL OPERATION 10C~32C 40 %~70 %16C~32C Setting Range of AUTO/MANUAL OperationCANCEL POWERFUL OPERATIONSTAINLESS PLASMA AIR PURIFYING FAN OPERATION STOPExample Cooling INFRARED HUMAN PRESENCE SENSING FUNCTIONDYNAMIC AIR DEFLECTION FUNCTION TRACING/EVASION Set the detection speed of the sensor to “Slow”Fine tune the detection speed of the sensor STOP While INTERNAL CLEANING OPERATIONSLEEP OPERATION MOLD MONITOR OPERATION Set automatically ADJUSTING THE VERTICAL AIRFLOW DIRECTIONVertical airflow swing Vertical air flow of your preferenceADJUSTING THE HORIZONTAL AIRFLOW DIRECTION Adjust the horizontal airflow directionHorizontal angle of your preference TIMER PRESET OPERATION How to preset the timerHow to preset the OFF TIMER ON TIMER How to cancel the preset timer ITALIANO FRANÇAIS DEUTSCHРУССКИЙ ∂ÏÏËÓÈο PORTUGUÊS SPANISH Combination of ON TIMER and DEHUMIDIFY button FURTHER CONVENIENT TIMER FUNCTIONCombination of Sleep Timer and On Timer operation SLEEP TIMER OPERATION1 Automatic filter cleaning operation FILTER CLEANING OPERATIONAbout the noise during filter cleaning Conditions under which automatic filter cleaning is performedITALIANO FRANÇAIS DEUTSCH ENGLISH STOP Press2 Manual filter cleaning operation FILTER CLEANING OPERATION continued3 Maintenance HOW TO PROHIBIT THE FILTER CLEANING OPERATIONReturn to the filter cleaning operation setting Set to prohibit the filter cleaning operationOperate the manual filter cleaning operation. Page Set to prohibit the filter cleaning operation againMaintenance of dust box MAINTENANCEStop the operation with the remote controller and 3 Turn on the power supply or turn on the circuit breakercontroller and unplug the power plug Maintenance of Stainless Mesh FilterStop the operation with the remote or turn off the circuit breakerMaintenance of mesh stainless filter continued MAINTENANCE continuedTurn on the power supply or turn on the circuit breaker Vacuum the dustthe power supply or turn off the circuit breaker Maintenance of dust catcherStop the operation with the remote controller and unplug Remove the front panel4 Turn on the power supply. or turn on the circuit breaker Maintenance of electric dust collector electrodesStop the operation with the remote controller and unplug the power supply or turn off theNAMES AND FUNCTIONS OF EACH PART Page UNDERSTANDING THE OPERATING MECHANISMTHE IDEAL WAYS OF OPERATION FILTER CLEANING OPERATION TROUBLESHOOTINGTROUBLESHOOTING continued PLEASE CHECK THE FOLLOWING BEFORE SERVICEANTI-MOLD WASABI CASSETTE THE FOLLOWING CASES DOES NOT INDICATE MALFUNCTION Reconnect the power supply Disconnect the power supplyAutomatic operation starts when the temporary switch Unplug the powerREGULAR INSPECTION INSPECTION AND MAINTENANCEDuring internal cleaning operation page OPERATION DISPLAY CHARTDuring preset of the mold monitor operation page DisplayMEMO 474 A 室内机 室外机 РУССКИЙ ∂ÏÏËÓÈο PORTUGUÊS SPANISH ITALIANO FRANÇAIS 中 国 语室内机/室外机 分 体 式 冷 气 机安装方面的注意事项 安全注意事项搬移或修理时的注意事项 使用上的注意事项使用上的注意事项 室外机的说明 各部的名称和功能中 国 语 室内机操作部和清扫部纳米钛空清网的安装方法 可以使运转开始的按钮 各部的名称和功能 继续功能选择部 防霉芥末盒的安装 1 打开前面板。2 安装防霉芥末盒。 3 关上前面板。 过滤网清扫部的动作确认 1 将电源线可靠地接入电源中。 警告2 进行接通电源后的动作检查。 进行过滤网清扫部的动作检查。 装入电池。 请准备好遥控器打开盖板 用有尖细端头的物品按下复位请准备好遥控器 继续 4 能够设定电流值标准/节省切换。操作遥控器时 自动运转 自动运转室温的微调节 风速的切换乾爽除湿运转 制热运转可设定的温度范围为16C ~ 32C。 围为 40% ~ 70% 。制冷运转 乾爽除湿运转 继续凉快运转 10 ~32 干燥除湿、凉快运转的自动/手动切换50 %~60 % 16 ~32不锈等离子空气清净送风运转 全功率运转乾爽除湿 以冷房运转为例 红外线人体检知传感器以暖房运转为例 动态导风(追踪/回避)运转机能传感器的检测速度设定为「慢速」 传感器检测速度微调内部清洁运转 功能选择 钮 快眠运转霉菌监视运转 自动设定 上下风向的调节上下风向摆动 上下喜好风向左右风向的调节 左右风向的摆动左右喜好调节 3 按 1 按定时器预约运转 定时器的预约方法定时预约的取消方法 4 按开机定时 与 乾爽除湿 钮的组合 更方便的定时器使用方法睡眠定时运转和开机定时的组合 睡眠定时运转开机定时 进行第二天早上的运转等。 1 预约 开机定时。 74, 75页过滤网清扫运转 1 自动过滤网清扫运转在过滤网清扫运转结束时 , 返回到 过滤网清扫运转时的声音 进行自动过滤网清扫运转的条件过滤网清扫运转(继续) 3 维护2 手动过滤网清扫运转 过滤网清扫运转禁止的设定方法1 过滤网清扫运转禁止的设定方法。 2 重新设定过滤网清扫运转禁止的方法。 3 进行手动过滤网清扫运转 80页 4 再一次设定过滤网清扫运转禁止的方法。 1 , 2 , 4 的设定方法, 80页清洁 指示灯反复出现闪烁、亮灯和变暗现象。非故障 请用遥控器停止操作, 断开电源。 或者切断断路器 用水清洗集尘盒。 集尘盒的保养方法接入电源。 或打开断路器) 在清扫机体前,请使用遥控器停止操作或者切断断路器。1 请用遥控器停止操作,并断开电源。 或者切断断路器 2 打开前面板。 不锈过滤网的保养方法3 拆下前面板。 4 拆下前面的不锈过滤网。不锈过滤网的保养方法(继续) 维护(继续)5 用吸尘器等吸掉灰尘。 6 安装不锈过滤网。请用遥控器停止操作,并断开电源。 捕尘器的保养方法或者切断断路器 。 拆下捕尘器。电气集尘器电极的保养方法 维护 继续1 请用遥控器停止操作,并断下电源。 或者切断断路器 2 请用双手轻轻打开上下导风板。 注意 3 用牙刷清除电气集尘器电极的脏污。各部的名称和功能 52页 运转的原理和希望用户事前了解的事项1. 建议用户设定为“恰当的室温”, 既省钱又有益於身体。 请不要将室温设定得过低或过高。对健康不利,且浪费电力。 更理想的使用方法拉上窗帘或百叶遮帘, 可以减少热量的进出, 更有效地用电。 2. 请时常换气。 注意 如果与燃气器具同一室使用时,必要进行换气。 3. 要外出时, 可有效利用霉菌监视功能。 (请参照霉菌监视运转) 4. 就寝时, 可有效利用定时功能。过滤网清扫部的动作的说明 遇到问题时遇到问题时 继续 防霉芥茉盒的说明请服务人员维修以前,请先检查以下事项 运转 指 这非有故障暂时运转 出现下述情况时,请迅即向销售店咨询进行暂时运转时,请先断开电源。 或切断断路器。) 再次接入电源。或打开断路器。) 按下暂时运转开关后, 会进行自动运转。检查整备 定期检查内部清洁运转中 运转显示快查表Page 474 A