Goodman Mfg R-410A manual Model Return Supply

Page 10

ACCESSORIES

 

 

 

*PH15[24-60]M4*

SQUARE TO ROUND CONVERTER

(DOWNFLOW APPLICATIONS)

 

 

 

 

 

12 1/4

 

14 3/4

C

 

 

 

 

 

S

D

22 3/4

16 ø

22 1/4

16 ø

 

 

A R

12 1/4

14 3/4

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ø

 

ø

22

3/4

 

18

22

1/4

18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MODEL

A

B

C

D

RETURN

SUPPLY

SQRPG101/102

22 3/4

12 1/4

22 1/4

14 3/4

16

16

SQRPG103

22 3/4

12 1/4

22 1/4

14 3/4

18

18

SQUARE TO ROUND CONVERTER

(HORIZONTAL APPLICATIONS)

B

C

MODEL

A

B

C

SQRPGH101/102

16

16 1/2

16 1/2

 

 

SQRPGH103

18

18 1/2

18 1/2

 

A

10

Measurements are in inches.

 

Image 10
Contents Service Instructions System Operation Scheduled MaintenanceProduct Design ServicingWiring Diagrams 16B Checking Fan & Blower Motor ECM MotorsRecognize Safety SYMBOLS, Words and Labels Important InformationSafe Refrigerant Handling Product Identification Accessories Part Number Description Fits ModelsRequires 1 filter Filter Size 16 x 25 xMeasurement in inches ACCESSORIES*PH1524-60M4 MOTORIZED/MANUAL Fresh AIR Dampers Downflow ApplicationsModel Return Supply ModelEconomizer GPH13MED103 Roof Curbs PGC101/102/103 46 1/4 39 3/8 14 1/2 12 1/2 x 15 x 22 1/2Product Design Location & ClearancesCompressors Indoor Blower MotorElectrical Wiring Line Voltage WiringHeating Cycle System OperationCooling Cooling CycleDefrost Cycle Airflow Adjustments for Indoor Blower MotorFAN Operation Thermostat Wiring Thermostat Fan Only ModeCFM Trim Adjust CFM DeliveryTypical Heat Pump System in Cooling Typical Heat Pump System in HeatingOnce a Month Scheduled MaintenanceOnce a Year Cooling /HEAT PUMP- Service Analysis Guide ServicingChecking Voltage Line Voltage NOW Present3C Heating Anticipator Checking Wiring3B Cooling Anticipator Indoor Blower MotorChecking Transformer and Control Circuit Single PhaseThree Phase Checking Contactor ContactsChecking High Pressure Control Checking Loss of Charge ProtectorChecking Capacitor Ammeter 15A Resistance Check15B Capacitance Check RELAY, StartChecking Motors APH15 M Series OnlyChart on Next Chart from Previous GPH15 M Series Only 16D Checking GE X13TM MotorsChecking Compressor Windings GE X13TM Motor Connections17B Ground Test Testing Compressor Windings17A Resistance Test Compressor Ground TestUnloader Test Procedure 17C Unloader Test Procedure17D Operation Test Testing Defrost Thermostat Testing Crankcase HeaterTesting Defrost Control Checking Reversing Valve and SolenoidEvacuation Leak Testing Nitrogen or NITROGEN-TRACEDRefrigeration Repair Practice Brazing MaterialsCharging An inaccurately charged system will cause future prob- lemsThermostatic Expansion Valve Final Charge AdjustmentChecking Compressor Efficiency TXV ValvesUnderfeeding Superheat and Subcooling Adjustment on TXV ApplicationsOverfeeding SuperheatSubcooling = SAT. Liquid TEMP. Liquid Line Temp Checking SubcoolingTwo Speed Application *PH1548**-*PH1560 Heat Pump Heating CyclePressure vs. Temperature Chart 410A Required Liquid Line Temperature Refrigerant Overcharge Checking Expansion Valve OperationChecking Restricted Liquid Line NON-CONDENSABLESReversing Valve Replacement Suction Line Drier Clean-Up MethodChecking External Static Pressure Checking Temperature RiseChecking Temperature Rise Total External StaticWiring Diagrams OT18-60A Outdoor ThermostatRoom Thermostat Single Phase HKR** Heat KIT PH15**M4Diagrams GPH13MED Economizer for *PH15**M4
Related manuals
Manual 26 pages 45.36 Kb

R-410A specifications

Goodman Manufacturing, a well-respected name in the HVAC industry, has made significant advancements with their R-410A refrigerant technology. R-410A, a hydrofluorocarbon (HFC), has positioned itself as a superior alternative to the older R-22 refrigerant, which has been phased out due to its ozone-depleting properties. Goodman’s commitment to energy efficiency and environmental sustainability is well reflected in their use of R-410A in their air conditioning and heat pump systems.

One of the main features of Goodman’s R-410A systems is their exceptional energy efficiency. The R-410A refrigerant operates at a higher pressure than R-22, which allows for better heat transfer and improved cooling capacity. This results in reduced energy consumption and lower utility bills for consumers. Goodman’s air conditioning units designed for use with R-410A are often rated with high Seasonal Energy Efficiency Ratio (SEER) ratings, making them an eco-friendly choice for residential and commercial applications.

Another notable technology employed by Goodman is their commitment to reliable performance through advanced compressor designs. Goodman's scroll compressors are optimized for R-410A, ensuring quieter operation and reducing vibration levels. These compressors are known for their efficiency and longevity, making them a favorite among homeowners seeking dependable and durable climate control solutions.

Goodman's multi-stage cooling systems that utilize R-410A offer precise temperature control and enhanced comfort. By controlling the speed of the compressor, Goodman’s units can adjust output according to the heating or cooling demand, maximizing comfort while minimizing energy waste. This adaptability not only enhances indoor air quality but also contributes to a greener environment by using less energy.

Furthermore, Goodman incorporates high-tech diagnostic controls into their systems. These controls provide real-time performance data, allowing homeowners and technicians to monitor system status and troubleshoot issues more easily. By using R-410A combined with these innovative technologies, Goodman emphasizes reliability and user-friendly operation.

In conclusion, Goodman Manufacturing’s use of R-410A refrigerant reflects their dedication to efficiency, reliability, and environmental stewardship in HVAC solutions. The combination of advanced compressor technologies, high energy efficiency, and innovative controls solidifies Goodman’s reputation as a leader in the industry, offering homeowners and businesses the comfort and peace of mind they deserve.