Goodman Mfg 13 SEER Heat Pump Heating Performance Overview

Page 38

SPLIT SYSTEM HEATING PERFORMANCE

EXPANDED PERFORMANCE DATA

MODEL: G/VSZ130361A* / AR*F364216**

 

 

 

 

 

 

 

 

 

HEATING OPERATION

 

 

 

 

 

 

 

Outdoor Ambient Temperature

 

 

 

 

 

 

 

 

 

65

60

55

50

47

45

40

35

30

25

20

17

15

10

5

0

-5

-10

MBh

42.7

40.5

38.1

35.6

34.0

32.9

30.6

28.2

19.9

18.4

16.9

16.0

15.4

13.8

12.3

10.7

9.1

7.5

DELTA T

31.0

29.4

27.7

25.9

24.7

23.9

22.2

20.5

14.5

13.4

12.3

11.6

11.2

10.0

8.9

7.8

6.6

5.4

KW

3.07

3.01

2.96

2.90

2.87

2.85

2.79

2.74

2.82

2.76

2.70

2.67

2.64

2.58

2.52

2.46

2.40

2.35

AMPS

14.2

13.2

12.3

11.6

11.2

11.0

10.4

9.9

9.4

9.0

8.6

8.4

8.3

7.9

7.4

7.0

6.5

5.8

COP

4.07

3.93

3.77

3.59

3.47

3.39

3.21

3.02

2.07

1.95

1.84

1.76

1.71

1.57

1.42

1.27

1.11

0.93

EER

13.9

13.4

12.9

12.3

11.8

11.6

11.0

10.3

7.1

6.7

6.3

6.0

5.8

5.4

4.9

4.3

3.8

3.2

HI PR

372

356

343

328

320

314

302

290

277

265

254

248

244

235

226

216

209

201

LO PR

133

123

115

106

100

96

89

79

71

64

56

52

50

42

37

31

27

21

 

MODEL: G/VSZ130361B* / AR*F364216**

 

 

 

 

 

 

 

 

 

 

HEATING OPERATION

 

 

 

 

 

 

 

 

Outdoor Ambient Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

60

55

50

47

45

40

35

30

25

20

17

15

10

5

0

-5

-10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MBh

42.7

40.5

38.1

35.6

34.0

32.9

30.6

28.2

2.6

2.4

2.2

2.1

2.0

1.8

1.6

1.4

1.2

1.0

 

Delta T

33.0

31.2

29.4

27.5

26.2

25.4

23.6

21.8

2.0

1.9

1.7

1.6

1.6

1.4

1.2

1.1

0.9

0.8

 

KW

3.09

3.03

2.97

2.90

2.87

2.84

2.79

2.73

2.70

2.64

2.58

2.54

2.52

2.45

2.39

2.33

2.27

2.21

 

AMPS

14.0

13.0

12.1

11.4

11.0

10.8

10.2

9.7

9.3

8.8

8.4

8.2

8.1

7.7

7.2

6.8

6.3

5.6

 

COP

4.05

3.91

3.76

3.59

3.47

3.39

3.21

3.03

0.28

0.27

0.25

0.24

0.23

0.22

0.20

0.18

0.15

0.13

 

EER

13.8

13.4

12.8

12.3

11.8

11.6

11.0

10.4

1.0

0.9

0.9

0.8

0.8

0.7

0.7

0.6

0.5

0.4

 

HI PR

383

368

353

338

330

324

311

299

286

273

262

256

251

242

233

223

215

208

 

LO PR

133

123

115

106

100

96

89

79

71

64

56

52

50

42

37

31

27

21

 

MODEL: GSZ130363A* / AR*F364216**

 

 

 

 

 

 

 

 

 

HEATING OPERATION

 

 

 

 

 

 

 

 

Outdoor Ambient Temperature

 

 

 

 

 

 

 

 

 

65

60

55

50

47

45

40

35

30

25

20

17

15

10

5

0

-5

-10

 

MBh

42.7

40.5

38.1

35.6

34.0

32.9

30.6

28.2

19.9

18.4

16.9

16.0

15.4

13.8

12.3

10.7

9.1

7.5

 

DT

31.0

29.4

27.7

25.9

24.7

23.9

22.2

20.5

14.5

13.4

12.3

11.6

11.2

10.0

8.9

7.8

6.6

5.4

 

KW

2.90

2.84

2.79

2.73

2.70

2.68

2.63

2.58

2.42

2.37

2.32

2.29

2.27

2.22

2.17

2.12

2.07

2.02

 

AMPS

9.9

9.2

8.7

8.2

7.9

7.8

7.4

7.0

6.7

6.5

6.2

6.0

6.0

5.7

5.3

5.1

4.7

4.3

 

COP

4.32

4.17

4.00

3.81

3.68

3.60

3.41

3.21

2.41

2.27

2.14

2.05

1.99

1.82

1.65

1.48

1.29

1.08

 

EER

14.8

14.2

13.7

13.0

12.6

12.3

11.6

11.0

8.2

7.8

7.3

7.0

6.8

6.2

5.7

5.0

4.4

3.7

 

HI PR

383

368

353

338

330

324

311

299

286

273

262

256

251

242

233

223

215

208

 

LO PR

138

128

120

110

104

100

92

82

74

66

58

54

52

44

38

32

28

22

High pressure is measured at the liquid service valve (the smaller valve). Low pressure is measured at the gauge port connection.

Calculations are based on nominal CFM and 70 °F indoor dry bulb.

AMPS = Outdoor unit amps (comp.+fan) KW = Total system power

*Note: Shaded area is AHRI Rating Conditions at 47° outdoor ambient temberature

38

Image 38
Contents Technical Manual 024 Product IdentificationProduct Identification Product Design AA AAProduct Dimensions Model Dimensions W x D x HHeat Pump Specifications VSZ13018-601AVSZ13024,36B SZ130241B SZ130361BGSZ13036-603,4A GSZ130363A GSZ130483A GSZ130484A GSZ130603A GSZ130604ACooling Performance Data VSZ130181A147 17.4375 VSZ130241A 378 Airflow23.0 141700 VSZ130241B800 357381 140VSZ130301A 383 28.410.3 145VSZ130361A 400 35.012.6 146VSZ130361B 397 Outdoor Ambient Temperature 105 11511.5 14532.92 GZ130363AModel GSZ130363A* / AR*F364216 1425 13.3 VSZ130421A 363 40.513.9 VSZ130481A 390 46.015.8 150373 GSZ130483AModel GSZ130483A* / AR*F486016 398 380 GSZ130484AModel GSZ130484A* / AR*F486016 405 VSZ130601A Expanded Perform Ance Data 10.8 GSZ130603AModel GSZ130603A* /AR*F486016 138 57.011.2 GSZ130604A Model GSZ130604A* /AR*F486016227 244 258 269 255 274 290 302 312 Outdoor Am bient Tem perature Split System Heating PerformanceOdel G/VSZ130301A AR*F30301 Outdoor Ambient Temperature 34.0Expanded Performance Data Outdoor Am bie nt Te m pe rature56.2 38665.0 60.7 33.4 31.2Performance Data Performance TestWiring VSZ13018-601A/BWiring Diagrams Wiring is subject to change, always refer to