Goodmans GPH 13 H Cooling Performance Data, GPH1324H41, 105 115 Entering Indoor Wet, 138

Page 13

13

MODEL: GPH1324H41**

 

 

 

 

EXPANDED PERFORMANCE DATA

 

 

 

COOLING OPERATION

 

 

Design Subcooling, 12±3 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 8±3 °F @ the compressor suction access fitting connection.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor Ambient Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

 

 

 

75

 

 

 

85

 

 

 

95

 

 

105

 

 

115

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Entering Indoor Wet

Bulb Temperature

 

 

 

 

 

 

 

 

 

IDB*

 

Airflow

 

59

63

 

67

71

59

63

 

67

71

59

63

 

67

71

59

63

 

67

71

59

63

67

71

59

63

67

71

 

 

 

MBh

23.5

24.4

 

26.7

-

23.0

23.8

 

26.1

-

22.4

23.2

 

25.5

-

21.9

22.7

 

24.8

-

20.8

21.5

23.6

-

19.3

20.0

21.9

-

 

 

 

S/T

0.80

0.67

0.46

-

0.83

0.69

0.48

-

0.85

0.71

0.49

-

0.88

0.73

0.51

-

0.91

0.76

0.53

-

0.92

0.77

0.53

-

 

 

980

Delta T

18

15

12

-

18

15

12

-

18

16

12

-

18

16

12

-

18

15

12

-

17

14

11

-

 

 

KW

1.71

1.74

1.80

-

1.83

1.87

1.93

-

1.95

1.99

2.05

-

2.05

2.09

2.16

-

2.13

2.18

2.25

-

2.20

2.25

2.32

-

 

 

 

AMPS

7.2

7.4

7.6

-

7.7

7.9

8.1

-

8.3

8.5

8.8

-

8.8

9.0

9.3

-

9.3

9.5

9.8

-

9.8

10.0

10.3

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HI PR

242

260

275

-

271

292

308

-

308

332

350

-

351

378

399

-

395

425

449

-

436

470

496

-

 

 

 

LO PR

112

119

130

-

118

126

137

-

123

131

143

-

129

137

150

-

135

144

157

-

140

149

163

-

 

 

 

MBh

22.8

23.7

25.9

-

22.3

23.1

25.3

-

21.8

22.6

24.7

-

21.2

22.0

24.1

-

20.2

20.9

22.9

-

18.7

19.4

21.2

-

 

 

 

S/T

0.76

0.64

0.44

-

0.79

0.66

0.46

-

0.81

0.68

0.47

-

0.84

0.70

0.49

-

0.87

0.73

0.50

-

0.88

0.73

0.51

-

70

 

875

Delta T

18

16

12

-

19

16

12

-

19

16

12

-

19

16

12

-

18

16

12

-

17

15

11

-

 

KW

1.69

1.73

1.78

-

1.82

1.86

1.92

-

1.93

1.97

2.03

-

2.03

2.07

2.14

-

2.11

2.16

2.23

-

2.18

2.23

2.31

-

 

 

 

AMPS

7.2

7.3

7.5

-

7.7

7.8

8.1

-

8.3

8.4

8.7

-

8.8

8.9

9.2

-

9.3

9.5

9.7

-

9.7

10.0

10.3

-

 

 

 

HI PR

239

257

272

-

268

289

305

-

305

328

347

-

348

374

395

-

391

421

444

-

432

465

491

-

 

 

 

LO PR

111

118

129

-

117

125

136

-

122

130

141

-

128

136

149

-

134

143

156

-

139

148

161

-

 

 

 

MBh

21.7

22.5

24.6

-

21.2

22.0

24.1

-

20.7

21.4

23.5

-

20.2

20.9

22.9

-

19.2

19.9

21.8

-

17.8

18.4

20.2

-

 

 

 

S/T

0.73

0.61

0.42

-

0.76

0.63

0.44

-

0.78

0.65

0.45

-

0.80

0.67

0.46

-

0.83

0.70

0.48

-

0.84

0.70

0.49

-

 

 

770

Delta T

19

16

12

-

19

17

13

-

19

17

13

-

19

17

13

-

19

17

13

-

18

15

12

-

 

 

KW

1.67

1.70

1.75

-

1.79

1.83

1.89

-

1.90

1.94

2.00

-

2.00

2.04

2.10

-

2.08

2.12

2.19

-

2.15

2.20

2.27

-

 

 

 

AMPS

7.1

7.2

7.4

-

7.6

7.7

7.9

-

8.1

8.3

8.5

-

8.6

8.8

9.1

-

9.1

9.3

9.6

-

9.6

9.8

10.1

-

 

 

 

HI PR

234

252

266

-

263

283

299

-

299

322

340

-

341

367

387

-

383

412

436

-

423

456

481

-

 

 

 

LO PR

109

116

126

-

115

122

133

-

119

127

139

-

125

133

146

-

131

140

153

-

136

145

158

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MBh

23.9

24.6

26.7

28.6

23.4

24.1

26.0

27.9

22.8

23.5

25.4

27.3

22.2

22.9

24.8

26.6

21.1

21.8

23.6

25.3

19.6

20.2

21.8

23.4

 

 

 

S/T

0.91

0.81

0.62

0.40

0.94

0.84

0.64

0.41

0.97

0.87

0.66

0.42

1.00

0.89

0.68

0.44

1.00

0.93

0.70

0.45

1.00

0.94

0.71

0.46

 

 

 

Delta T

20

19

15

11

21

19

16

11

21

19

16

11

21

19

16

11

20

19

16

11

18

18

14

10

 

 

980

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KW

1.72

1.76

1.81

1.87

1.85

1.89

1.95

2.01

1.96

2.00

2.07

2.13

2.06

2.11

2.17

2.25

2.15

2.19

2.27

2.34

2.22

2.27

2.34

2.42

 

 

 

AMPS

7.3

7.5

7.7

7.9

7.8

8.0

8.2

8.5

8.4

8.6

8.8

9.1

8.9

9.1

9.4

9.7

9.4

9.6

9.9

10.2

9.9

10.1

10.4

10.8

 

 

 

HI PR

244

263

277

289

274

295

311

325

311

335

354

369

355

382

403

420

399

429

453

473

441

474

501

523

 

 

 

LO PR

113

120

131

140

120

127

139

148

124

132

144

154

131

139

152

161

137

146

159

169

142

151

164

175

 

 

 

MBh

23.2

23.9

25.9

27.8

22.7

23.4

25.3

27.1

22.1

22.8

24.7

26.5

21.6

22.2

 

24.1

25.8

20.5

21.1

22.9

24.5

19.0

19.6

21.2

22.7

 

 

 

S/T

0.87

0.78

0.59

0.38

0.90

0.81

0.61

0.39

0.92

0.83

0.63

0.40

0.95

0.85

 

0.65

0.42

0.99

0.88

0.67

0.43

1.00

0.89

0.68

0.43

75

 

875

Delta T

21

20

16

11

21

20

16

11

21

20

16

11

22

20

 

16

11

21

20

16

11

20

18

15

10

 

KW

1.71

1.74

1.80

1.85

1.83

1.87

1.93

1.99

1.95

1.99

2.05

2.12

2.05

2.09

 

2.16

2.23

2.13

2.18

2.25

2.32

2.20

2.25

2.32

2.40

 

 

 

AMPS

7.2

7.4

7.6

7.8

7.7

7.9

8.1

8.4

8.3

8.5

8.8

9.0

8.8

9.0

 

9.3

9.6

9.3

9.5

9.8

10.2

9.8

10.0

10.3

10.7

 

 

 

HI PR

242

260

275

286

271

292

308

321

308

332

350

365

351

378

 

399

416

395

425

449

468

437

470

496

517

 

 

 

LO PR

112

119

130

139

118

126

138

146

123

131

143

152

129

138

 

150

160

135

144

157

168

140

149

163

173

 

 

 

MBh

22.1

22.7

24.6

26.4

21.5

22.2

24.0

25.8

21.0

21.7

23.4

25.2

20.5

21.1

 

22.9

24.5

19.5

20.1

21.7

23.3

18.1

18.6

20.1

21.6

 

 

 

S/T

0.83

0.74

0.56

0.36

0.86

0.77

0.58

0.38

0.88

0.79

0.60

0.39

0.91

0.82

0.62

0.40

0.95

0.85

0.64

0.41

0.96

0.85

0.65

0.42

 

 

770

Delta T

22

20

17

11

22

20

17

12

22

20

17

12

22

21

17

12

22

20

17

11

21

19

16

11

 

 

KW

1.68

1.72

1.77

1.82

1.81

1.84

1.90

1.96

1.92

1.96

2.02

2.08

2.01

2.06

2.12

2.19

2.10

2.14

2.21

2.28

2.17

2.21

2.29

2.36

 

 

 

AMPS

7.1

7.3

7.5

7.7

7.6

7.8

8.0

8.3

8.2

8.4

8.6

8.9

8.7

8.9

9.1

9.4

9.2

9.4

9.7

10.0

9.7

9.9

10.2

10.5

 

 

 

HI PR

237

255

269

281

266

286

302

315

302

325

343

358

344

370

391

408

387

417

440

459

428

460

486

507

 

 

 

LO PR

110

117

128

136

116

123

135

144

121

128

140

149

127

135

147

157

133

141

154

164

137

146

159

170

 

* Entering Indoor Dry Bulb Temperature

 

 

NOTE: Shaded area is ACCA (TVA) conditions

 

 

 

 

 

 

 

 

 

 

 

 

 

High and low pressures are measured at the liquid and suction access fittings.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COOLING PERFORMANCE DATA

GPH1324H41**

Image 13
Contents Technical Manual Goodman will not be responsible Product IdentificationFor any injury or property damage Do not connect or use any device Product Design Outside Slab Installation Horizontal HRooftop Installation Horizontal H Minimum Circuit Maximum Electrical Data *Blower Only, Heat ModeOvercurrent Ampacity Protection ampsGPH1324-60H41 Product DimensionsGPH1324-36H41AB GPH1336H41AC Package Heat Pump SpecificationsGPH1342H41AB GPH1348-60H41BB Part Number Description AccessoriesGPH1324-60H41 Blower Performance DataFormulas Performance DataGPH1324H41 Cooling Performance Data105 115 Entering Indoor Wet 13824.0 105 115 Entering Indoor Wet Bulb Temperature105 115 GPH1330H41Airflow 26.111.2 28.2412 15132.4 GPH1336H41149 35.037.5 GPH1342H4140.5 Outdoor Ambient Temperature 105 11515.8 39242.6 GPH1348H4146.0 GPH1360H41 21.1 57.5388 Package Heat Pump Specifications GPH1342-60H41 GPH1324, 30, 42H41AB / GPH1336H41AC GPH1348H41BB Wiring DiagramsBefore Servicing Sources MAY be Property Damage GPH1360H41BB

GPH 13 H, Package Heat Pump Units specifications

Goodmans Package Heat Pump Units, specifically the GPH 13 H model, represent an advanced solution in residential and commercial climate control. Known for their efficiency and reliability, these heat pumps offer a combination of heating and cooling capabilities, making them ideal for year-round comfort.

One of the standout features of the GPH 13 H is its energy efficiency rating. With a SEER (Seasonal Energy Efficiency Ratio) of 13, it efficiently converts energy into heating and cooling, which can lead to significant savings on utility bills. This efficiency is not only beneficial for homeowners looking to reduce their energy footprint, but it also qualifies for many energy rebate programs.

Durability is another hallmark of the GPH 13 H. Built with robust materials, the unit is designed to withstand various weather conditions, ensuring longevity and reliable performance. Components are treated to resist corrosion, which extends the lifespan of the heat pump and enhances its efficiency.

The GPH 13 H utilizes innovative inverter technology, allowing it to adjust its cooling and heating output according to the space's specific needs. This results in more consistent temperatures and improved indoor comfort. Additionally, the variable-speed compressor operates at different levels, reducing energy consumption while providing effective heating and cooling.

In terms of installation, the GPH 13 H offers versatility. Its compact design facilitates easy placement in various locations, making it suitable for both new construction and retrofitting existing spaces. The unit's all-in-one design simplifies installation by minimizing the need for external ductwork.

Quiet operation is a critical consideration for many homeowners, and Goodmans excels in this area. The GPH 13 H is engineered to minimize noise levels, ensuring a peaceful indoor environment. This feature makes it an excellent choice for residential areas where noise may be a concern.

The unit also features advanced control systems, including programmable thermostats that allow users to set specific temperature schedules. This feature not only enhances user comfort but also contributes to energy savings by preventing unnecessary heating or cooling when spaces are unoccupied.

Overall, Goodmans Package Heat Pump Units, GPH 13 H, combine efficiency, durability, and advanced technology to deliver a reliable climate control solution. With its focus on energy savings, quiet operation, and flexibility in installation, this model stands out as a leading choice for those seeking optimal home comfort. Its thoughtful design and engineering make it a worthwhile investment in both residential and commercial settings.