MODEL: GPH1336H41**

 

 

 

 

EXPANDED PERFORMANCE DATA

 

 

 

COOLING OPERATION

 

 

Design Subcooling, 12±3 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 8±3 °F @ the compressor suction access fitting connection.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor Ambient Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

 

 

 

75

 

 

 

85

 

 

 

95

 

 

105

 

 

115

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Entering Indoor Wet

Bulb Temperature

 

 

 

 

 

 

 

 

 

IDB*

 

Airflow

 

59

63

 

67

71

59

63

 

67

71

59

63

 

67

71

59

63

 

67

71

59

63

67

71

59

63

67

71

 

 

 

MBh

35.5

36.3

 

38.8

41.4

34.7

35.4

 

37.9

40.5

33.8

34.6

 

37.0

39.5

33.0

33.7

 

36.1

38.5

31.4

32.1

34.2

36.6

29.1

29.7

31.7

33.9

 

 

 

S/T

0.94

0.89

0.72

0.54

1.00

0.92

0.75

0.56

1.00

0.94

0.77

0.57

1.00

1.00

0.79

0.59

1.00

1.00

0.82

0.61

1.00

1.00

0.83

0.62

 

 

1350

Delta T

23

22

19

15

24

22

19

15

23

22

19

15

22

23

19

16

21

22

19

15

20

20

18

14

 

 

KW

2.65

2.70

2.78

2.87

2.84

2.90

2.99

3.08

3.01

3.07

3.17

3.27

3.16

3.23

3.33

3.43

3.29

3.36

3.46

3.57

3.40

3.47

3.58

3.70

 

 

 

AMPS

11.3

11.5

11.8

12.2

12.0

12.3

12.6

13.0

12.9

13.2

13.5

14.0

13.7

14.0

14.4

14.8

14.4

14.7

15.2

15.7

15.2

15.5

16.0

16.5

 

 

 

HI PR

252

271

287

299

283

305

322

335

322

346

366

381

367

394

417

434

412

444

469

489

456

490

518

540

 

 

 

LO PR

112

120

131

139

119

126

138

147

123

131

143

153

130

138

151

160

136

145

158

168

141

149

163

174

 

 

 

MBh

34.5

35.2

37.6

40.2

33.7

34.4

36.8

39.3

32.9

33.6

35.9

38.4

32.1

32.8

 

35.0

37.4

30.5

31.1

33.3

35.5

28.2

28.8

30.8

32.9

 

 

 

S/T

0.90

0.84

0.69

0.51

0.93

0.88

0.71

0.53

0.96

0.90

0.73

0.55

0.99

0.93

 

0.75

0.56

1.00

0.96

0.78

0.59

1.00

0.97

0.79

0.59

80

 

1200

Delta T

24

23

20

16

24

23

20

16

24

23

20

16

24

23

 

20

16

23

23

20

16

22

21

19

15

 

KW

2.63

2.68

2.76

2.84

2.82

2.88

2.96

3.06

2.99

3.05

3.14

3.24

3.13

3.20

 

3.30

3.41

3.26

3.33

3.44

3.55

3.37

3.44

3.55

3.67

 

 

 

AMPS

11.2

11.4

11.7

12.1

11.9

12.2

12.5

12.9

12.8

13.1

13.4

13.9

13.6

13.8

 

14.2

14.7

14.3

14.6

15.0

15.5

15.0

15.4

15.8

16.4

 

 

 

HI PR

250

269

284

296

280

301

318

332

319

343

362

378

363

391

 

412

430

408

439

464

484

451

485

513

535

 

 

 

LO PR

111

118

129

138

118

125

137

145

122

130

142

151

128

137

 

149

159

134

143

156

166

139

148

162

172

 

 

 

MBh

31.8

32.5

34.7

37.1

31.1

31.7

33.9

36.3

30.3

31.0

33.1

35.4

29.6

30.2

 

32.3

34.5

28.1

28.7

30.7

32.8

26.0

26.6

28.4

30.4

 

 

 

S/T

0.87

0.81

0.66

0.50

0.90

0.84

0.69

0.51

0.92

0.87

0.70

0.53

0.95

0.89

0.73

0.54

0.99

0.93

0.75

0.56

1.00

0.94

0.76

0.57

 

 

 

Delta T

24

23

20

16

24

23

20

16

25

23

20

16

25

24

21

16

24

23

20

16

23

22

19

15

 

 

1050

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KW

2.57

2.62

2.70

2.78

2.75

2.81

2.89

2.98

2.92

2.98

3.07

3.16

3.06

3.12

3.22

3.32

3.18

3.25

3.35

3.46

3.29

3.36

3.46

3.58

 

 

 

AMPS

10.9

11.2

11.5

11.8

11.7

11.9

12.2

12.6

12.5

12.8

13.1

13.5

13.2

13.5

13.9

14.4

14.0

14.3

14.7

15.2

14.7

15.0

15.4

16.0

 

 

 

HI PR

242

261

275

287

272

292

309

322

309

333

351

366

352

379

400

417

396

426

450

469

438

471

497

519

 

 

 

LO PR

108

115

125

133

114

121

132

141

119

126

138

147

124

132

145

154

130

139

152

161

135

144

157

167

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MBh

36.1

36.8

38.6

41.1

35.3

36.0

37.7

40.2

34.4

35.1

36.8

39.2

33.6

34.2

35.9

38.3

31.9

32.5

34.1

36.4

29.6

30.1

31.6

33.7

 

 

 

S/T

0.99

0.96

0.86

0.70

1.00

0.99

0.89

0.73

1.00

1.00

0.92

0.74

1.00

1.00

0.95

0.77

1.00

1.00

0.98

0.80

1.00

1.00

0.99

0.80

 

 

1350

Delta T

24

24

23

20

24

24

23

20

23

24

23

20

23

23

23

20

22

22

23

20

20

21

21

18

 

 

KW

2.67

2.72

2.80

2.89

2.86

2.92

3.01

3.10

3.03

3.10

3.19

3.29

3.18

3.25

3.35

3.46

3.31

3.38

3.49

3.60

3.42

3.50

3.61

3.73

 

 

 

AMPS

11.4

11.6

11.9

12.3

12.1

12.4

12.7

13.1

13.0

13.3

13.7

14.1

13.8

14.1

14.5

14.9

14.5

14.8

15.3

15.8

15.3

15.6

16.1

16.6

 

 

 

HI PR

255

274

289

302

286

308

325

339

325

350

369

385

370

398

421

439

416

448

473

494

460

495

523

545

 

 

 

LO PR

114

121

132

140

120

128

139

148

125

133

145

154

131

139

152

162

137

146

159

170

142

151

165

176

 

 

 

MBh

35.1

35.7

37.4

39.9

34.3

34.9

36.6

39.0

33.4

34.1

35.7

38.1

32.6

33.3

34.8

37.2

31.0

31.6

33.1

35.3

28.7

29.3

30.6

32.7

 

 

 

S/T

0.94

0.91

0.82

0.67

0.98

0.94

0.85

0.69

1.00

0.97

0.87

0.71

1.00

1.00

0.90

0.73

1.00

1.00

0.94

0.76

1.00

1.00

0.94

0.77

85

 

1200

Delta T

25

25

24

20

26

25

24

21

26

25

24

21

25

25

24

21

24

24

24

21

22

22

22

19

 

KW

2.65

2.70

2.78

2.87

2.84

2.90

2.99

3.08

3.01

3.07

3.17

3.27

3.16

3.23

3.33

3.43

3.29

3.36

3.46

3.57

3.40

3.47

3.58

3.70

 

 

 

AMPS

11.3

11.5

11.8

12.2

12.0

12.3

12.6

13.0

12.9

13.2

13.5

14.0

13.7

14.0

14.4

14.8

14.4

14.7

15.2

15.7

15.2

15.5

16.0

16.5

 

 

 

HI PR

252

271

287

299

283

305

322

335

322

346

366

381

367

394

417

434

412

444

469

489

456

490

518

540

 

 

 

LO PR

112

120

131

139

119

126

138

147

123

131

143

153

130

138

151

160

136

145

158

168

141

149

163

174

 

 

 

MBh

32.4

33.0

34.6

36.9

31.6

32.2

33.8

36.0

30.9

31.5

32.9

35.1

30.1

30.7

32.1

34.3

28.6

29.2

30.5

32.6

26.5

27.0

28.3

30.2

 

 

 

S/T

0.91

0.88

0.79

0.64

0.94

0.91

0.82

0.67

0.97

0.93

0.84

0.68

1.00

0.96

0.87

0.71

1.00

1.00

0.90

0.73

1.00

1.00

0.91

0.74

 

 

1050

Delta T

26

25

24

21

26

26

24

21

26

26

24

21

26

26

24

21

25

26

24

21

23

24

23

20

 

 

KW

2.59

2.64

2.72

2.80

2.78

2.83

2.92

3.01

2.94

3.00

3.09

3.19

3.08

3.15

3.25

3.35

3.21

3.28

3.38

3.49

3.31

3.39

3.49

3.61

 

 

 

AMPS

11.0

11.2

11.5

11.9

11.8

12.0

12.3

12.7

12.6

12.9

13.2

13.7

13.3

13.6

14.0

14.5

14.1

14.4

14.8

15.3

14.8

15.1

15.6

16.1

 

 

 

HI PR

245

263

278

290

274

295

312

325

312

336

355

370

356

383

404

421

400

430

455

474

442

476

502

524

 

 

 

LO PR

109

116

127

135

115

123

134

142

120

127

139

148

126

134

146

156

132

140

153

163

136

145

158

169

 

* Entering Indoor Dry Bulb Temperature

 

 

NOTE: Shaded area

is AHRI Rating Conditions

 

 

 

KW = Total system power

 

 

 

 

 

 

High and low pressures are measured at the liquid and suction access fittings.

 

 

 

 

 

 

 

 

 

AMPS: Unit amps (comp.+ evaporator + condenser fan motors)

 

COOLING PERFORMANCE DATA

GPH1336H41**

Image 18
Contents Technical Manual Product Identification Goodman will not be responsibleFor any injury or property damage Do not connect or use any device Outside Slab Installation Horizontal H Product DesignRooftop Installation Horizontal H Overcurrent Electrical Data *Blower Only, Heat ModeMinimum Circuit Maximum Ampacity Protection ampsProduct Dimensions GPH1324-60H41Package Heat Pump Specifications GPH1324-36H41AB GPH1336H41ACGPH1342H41AB GPH1348-60H41BB Accessories Part Number DescriptionBlower Performance Data GPH1324-60H41Performance Data Formulas105 115 Entering Indoor Wet Cooling Performance DataGPH1324H41 138105 115 Entering Indoor Wet Bulb Temperature 24.0Airflow GPH1330H41105 115 26.1412 28.211.2 151GPH1336H41 32.435.0 149GPH1342H41 37.515.8 Outdoor Ambient Temperature 105 11540.5 392GPH1348H41 42.646.0 GPH1360H41 57.5 21.1388 Package Heat Pump Specifications GPH1342-60H41 Wiring Diagrams GPH1324, 30, 42H41AB / GPH1336H41AC GPH1348H41BBGPH1360H41BB Before Servicing Sources MAY be Property Damage

GPH 13 H, Package Heat Pump Units specifications

Goodmans Package Heat Pump Units, specifically the GPH 13 H model, represent an advanced solution in residential and commercial climate control. Known for their efficiency and reliability, these heat pumps offer a combination of heating and cooling capabilities, making them ideal for year-round comfort.

One of the standout features of the GPH 13 H is its energy efficiency rating. With a SEER (Seasonal Energy Efficiency Ratio) of 13, it efficiently converts energy into heating and cooling, which can lead to significant savings on utility bills. This efficiency is not only beneficial for homeowners looking to reduce their energy footprint, but it also qualifies for many energy rebate programs.

Durability is another hallmark of the GPH 13 H. Built with robust materials, the unit is designed to withstand various weather conditions, ensuring longevity and reliable performance. Components are treated to resist corrosion, which extends the lifespan of the heat pump and enhances its efficiency.

The GPH 13 H utilizes innovative inverter technology, allowing it to adjust its cooling and heating output according to the space's specific needs. This results in more consistent temperatures and improved indoor comfort. Additionally, the variable-speed compressor operates at different levels, reducing energy consumption while providing effective heating and cooling.

In terms of installation, the GPH 13 H offers versatility. Its compact design facilitates easy placement in various locations, making it suitable for both new construction and retrofitting existing spaces. The unit's all-in-one design simplifies installation by minimizing the need for external ductwork.

Quiet operation is a critical consideration for many homeowners, and Goodmans excels in this area. The GPH 13 H is engineered to minimize noise levels, ensuring a peaceful indoor environment. This feature makes it an excellent choice for residential areas where noise may be a concern.

The unit also features advanced control systems, including programmable thermostats that allow users to set specific temperature schedules. This feature not only enhances user comfort but also contributes to energy savings by preventing unnecessary heating or cooling when spaces are unoccupied.

Overall, Goodmans Package Heat Pump Units, GPH 13 H, combine efficiency, durability, and advanced technology to deliver a reliable climate control solution. With its focus on energy savings, quiet operation, and flexibility in installation, this model stands out as a leading choice for those seeking optimal home comfort. Its thoughtful design and engineering make it a worthwhile investment in both residential and commercial settings.