Goodmans Package Heat Pump Units Outdoor Ambient Temperature 105 115, 40.5, 15.8, 392, 153

Page 20

20

MODEL: GPH1342H41**

 

 

 

 

EXPANDED PERFORMANCE DATA

 

 

 

 

COOLING OPERATION

 

 

Design Subcooling, 12±3 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 8±3 °F @ the compressor suction access fitting connection.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor Ambient Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

 

 

 

75

 

 

 

85

 

 

 

95

 

 

 

105

 

 

 

115

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Entering Indoor Wet

Bulb Temperature

 

 

 

 

 

 

 

 

 

 

 

 

IDB*

 

Airflow

 

59

63

 

67

71

59

63

 

67

71

59

63

 

67

71

59

63

 

67

71

59

 

63

67

71

59

 

63

 

67

71

 

 

 

MBh

41.1

42.0

 

44.8

47.9

40.1

41.0

 

43.8

46.8

39.2

40.0

 

42.8

45.7

38.2

39.0

 

41.7

44.6

36.3

 

37.1

39.6

42.4

33.6

 

34.4

 

36.7

39.2

 

 

 

S/T

0.95

0.89

0.72

0.54

1.00

0.92

0.75

0.56

1.00

0.94

0.77

0.57

1.00

1.00

0.79

0.59

1.00

 

1.00

0.82

0.62

1.00

 

1.00

 

0.83

0.62

 

 

1585

Delta T

23

22

19

15

23

22

19

15

23

22

19

15

22

23

19

15

21

 

22

19

15

20

 

20

 

18

14

 

 

KW

2.87

2.92

3.01

3.09

3.07

3.13

3.22

3.32

3.24

3.31

3.41

3.52

3.40

3.47

3.58

3.69

3.54

 

3.61

3.72

3.84

3.65

 

3.73

 

3.84

3.96

 

 

 

AMPS

12.6

12.8

13.2

13.6

13.4

13.7

14.1

14.5

14.4

14.7

15.1

15.6

15.2

15.5

16.0

16.5

16.0

 

16.4

16.8

17.4

16.9

 

17.2

 

17.7

18.3

 

 

 

HI PR

240

258

273

284

269

290

306

319

306

329

348

363

349

375

396

413

392

 

422

446

465

433

 

466

 

493

514

 

 

 

LO PR

116

123

134

143

122

130

142

151

127

135

147

157

133

142

155

165

140

 

149

162

173

144

 

154

 

168

179

 

 

 

MBh

39.9

40.8

43.5

46.5

39.0

39.8

42.5

45.5

38.0

38.9

41.5

44.4

37.1

37.9

 

40.5

43.3

35.2

 

36.0

38.5

41.1

32.6

 

33.4

 

35.6

38.1

 

 

 

S/T

0.90

0.85

0.69

0.52

0.94

0.88

0.71

0.53

0.96

0.90

0.73

0.55

0.99

0.93

 

0.76

0.57

1.00

 

0.96

0.79

0.59

1.00

 

0.97

 

0.79

0.59

80

 

1410

Delta T

23

23

20

16

24

23

20

16

24

23

20

16

24

23

 

20

16

23

 

23

20

16

21

 

21

 

18

15

 

KW

2.85

2.90

2.98

3.07

3.04

3.10

3.20

3.29

3.22

3.29

3.38

3.49

3.38

3.45

 

3.55

3.66

3.51

 

3.58

3.69

3.81

3.62

 

3.70

 

3.81

3.93

 

 

 

AMPS

12.5

12.7

13.1

13.5

13.3

13.6

14.0

14.4

14.3

14.6

15.0

15.4

15.1

15.4

 

15.8

16.4

15.9

 

16.2

16.7

17.3

16.7

 

17.1

 

17.6

18.2

 

 

 

HI PR

238

256

270

282

267

287

303

316

303

326

344

359

345

372

 

392

409

388

 

418

441

460

429

 

462

 

488

509

 

 

 

LO PR

114

122

133

142

121

129

140

150

126

134

146

155

132

140

 

153

163

138

 

147

161

171

143

 

152

 

166

177

 

 

 

MBh

36.8

37.6

40.2

43.0

36.0

36.7

39.3

42.0

35.1

35.9

38.3

41.0

34.2

35.0

 

37.4

40.0

32.5

 

33.2

35.5

38.0

30.1

 

30.8

 

32.9

35.2

 

 

 

S/T

0.87

0.82

0.66

0.50

0.90

0.85

0.69

0.52

0.93

0.87

0.71

0.53

0.96

0.90

0.73

0.55

0.99

 

0.93

0.76

0.57

1.00

 

0.94

 

0.76

0.57

 

 

 

Delta T

24

23

20

16

24

23

20

16

24

23

20

16

24

23

20

16

24

 

23

20

16

22

 

21

 

19

15

 

 

1236

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KW

2.78

2.84

2.92

3.00

2.98

3.04

3.12

3.22

3.15

3.21

3.31

3.41

3.30

3.37

3.47

3.57

3.43

 

3.50

3.60

3.72

3.54

 

3.61

 

3.72

3.84

 

 

 

AMPS

12.2

12.5

12.8

13.2

13.0

13.3

13.6

14.1

13.9

14.2

14.6

15.1

14.7

15.0

15.5

16.0

15.5

 

15.9

16.3

16.8

16.3

 

16.7

 

17.2

17.7

 

 

 

HI PR

230

248

262

273

259

278

294

306

294

316

334

349

335

360

381

397

377

 

405

428

447

416

 

448

 

473

493

 

 

 

LO PR

111

118

129

137

117

125

136

145

122

130

142

151

128

136

149

158

134

 

143

156

166

139

 

148

 

161

172

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MBh

41.8

42.6

44.6

47.6

40.8

41.6

43.6

46.5

39.9

40.6

42.5

45.4

38.9

39.6

41.5

44.3

36.9

 

37.6

39.4

42.1

34.2

 

34.9

 

36.5

39.0

 

 

 

S/T

0.99

0.96

0.86

0.70

1.00

0.99

0.90

0.73

1.00

1.00

0.92

0.75

1.00

1.00

0.95

0.77

1.00

 

1.00

0.98

0.80

1.00

 

1.00

 

0.99

0.81

 

 

1585

Delta T

24

24

22

19

24

24

23

20

23

24

23

20

23

23

23

20

21

 

22

23

19

20

 

20

 

21

18

 

 

KW

2.89

2.94

3.03

3.12

3.09

3.15

3.24

3.34

3.27

3.34

3.44

3.54

3.43

3.50

3.61

3.72

3.56

 

3.64

3.75

3.87

3.68

 

3.76

 

3.87

4.00

 

 

 

AMPS

12.7

12.9

13.3

13.7

13.5

13.8

14.2

14.6

14.5

14.8

15.2

15.7

15.3

15.6

16.1

16.6

16.2

 

16.5

17.0

17.5

17.0

 

17.4

 

17.9

18.5

 

 

 

HI PR

242

261

275

287

272

293

309

322

309

333

351

367

352

379

400

417

396

 

426

450

470

438

 

471

 

497

519

 

 

 

LO PR

117

124

136

144

123

131

143

153

128

136

149

159

135

143

156

166

141

 

150

164

174

146

 

155

 

169

180

 

 

 

MBh

40.6

41.4

43.3

46.2

39.6

40.4

42.3

45.1

38.7

39.4

41.3

44.1

37.7

38.5

40.3

43.0

35.9

 

36.6

38.3

40.8

33.2

 

33.9

 

35.5

37.8

 

 

 

S/T

0.95

0.91

0.82

0.67

0.98

0.95

0.85

0.69

1.00

0.97

0.88

0.71

1.00

1.00

0.90

0.73

1.00

 

1.00

0.94

0.76

1.00

 

1.00

 

0.95

0.77

85

 

1410

Delta T

25

25

23

20

25

25

24

20

25

25

24

20

25

25

24

21

23

 

24

23

20

22

 

22

 

22

19

 

KW

2.87

2.92

3.01

3.09

3.07

3.13

3.22

3.32

3.24

3.31

3.41

3.52

3.40

3.47

3.58

3.69

3.54

 

3.61

3.72

3.84

3.65

 

3.73

 

3.84

3.96

 

 

 

AMPS

12.6

12.8

13.2

13.6

13.4

13.7

14.1

14.5

14.4

14.7

15.1

15.6

15.2

15.5

16.0

16.5

16.0

 

16.4

16.8

17.4

16.9

 

17.2

 

17.7

18.3

 

 

 

HI PR

240

258

273

284

269

290

306

319

306

329

348

363

349

375

396

413

392

 

422

446

465

433

 

466

 

493

514

 

 

 

LO PR

116

123

134

143

122

130

142

151

127

135

147

157

133

142

155

165

140

 

149

162

173

144

 

154

 

168

179

 

 

 

MBh

37.5

38.2

40.0

42.7

36.6

37.3

39.1

41.7

35.7

36.4

38.1

40.7

34.8

35.5

37.2

39.7

33.1

 

33.7

35.3

37.7

30.7

 

31.3

 

32.7

34.9

 

 

 

S/T

0.91

0.88

0.80

0.65

0.95

0.91

0.82

0.67

0.97

0.94

0.85

0.69

1.00

0.97

0.87

0.71

1.00

 

1.00

0.91

0.73

1.00

 

1.00

 

0.91

0.74

 

 

1236

Delta T

25

25

24

20

26

25

24

21

26

25

24

21

26

26

24

21

25

 

25

24

21

23

 

23

 

22

19

 

 

KW

2.80

2.86

2.94

3.03

3.00

3.06

3.15

3.24

3.17

3.23

3.33

3.43

3.32

3.39

3.49

3.60

3.45

 

3.52

3.63

3.75

3.56

 

3.64

 

3.75

3.87

 

 

 

AMPS

12.3

12.5

12.9

13.3

13.1

13.4

13.7

14.2

14.0

14.3

14.7

15.2

14.9

15.2

15.6

16.1

15.7

 

16.0

16.4

17.0

16.5

 

16.8

 

17.3

17.9

 

 

 

HI PR

233

250

264

276

261

281

297

310

297

320

337

352

338

364

384

401

381

 

410

432

451

420

 

452

 

478

498

 

 

 

LO PR

112

119

130

139

118

126

138

146

123

131

143

152

129

138

150

160

135

 

144

157

168

140

 

149

 

163

173

 

* Entering Indoor Dry Bulb Temperature

 

 

NOTE: Shaded area is AHRI Rating Conditions

 

 

 

KW = Total system power

 

 

 

 

 

 

 

 

 

High and low pressures are measured at the liquid and suction access fittings.

 

 

 

 

 

 

 

 

 

AMPS: Unit amps (comp.+ evaporator + condenser fan motors)

 

 

COOLING PERFORMANCE DATA

GPH1342H41**

Image 20
Contents Technical Manual For any injury or property damage Product IdentificationGoodman will not be responsible Do not connect or use any device Outside Slab Installation Horizontal H Product DesignRooftop Installation Horizontal H Electrical Data *Blower Only, Heat Mode Minimum Circuit MaximumOvercurrent Ampacity Protection ampsProduct Dimensions GPH1324-60H41Package Heat Pump Specifications GPH1324-36H41AB GPH1336H41ACGPH1342H41AB GPH1348-60H41BB Accessories Part Number DescriptionBlower Performance Data GPH1324-60H41Performance Data FormulasCooling Performance Data GPH1324H41105 115 Entering Indoor Wet 138105 115 Entering Indoor Wet Bulb Temperature 24.0GPH1330H41 105 115Airflow 26.128.2 11.2412 151GPH1336H41 32.435.0 149GPH1342H41 37.5Outdoor Ambient Temperature 105 115 40.515.8 392GPH1348H41 42.646.0 GPH1360H41 388 57.521.1 Package Heat Pump Specifications GPH1342-60H41 Wiring Diagrams GPH1324, 30, 42H41AB / GPH1336H41AC GPH1348H41BBGPH1360H41BB Before Servicing Sources MAY be Property Damage

GPH 13 H, Package Heat Pump Units specifications

Goodmans Package Heat Pump Units, specifically the GPH 13 H model, represent an advanced solution in residential and commercial climate control. Known for their efficiency and reliability, these heat pumps offer a combination of heating and cooling capabilities, making them ideal for year-round comfort.

One of the standout features of the GPH 13 H is its energy efficiency rating. With a SEER (Seasonal Energy Efficiency Ratio) of 13, it efficiently converts energy into heating and cooling, which can lead to significant savings on utility bills. This efficiency is not only beneficial for homeowners looking to reduce their energy footprint, but it also qualifies for many energy rebate programs.

Durability is another hallmark of the GPH 13 H. Built with robust materials, the unit is designed to withstand various weather conditions, ensuring longevity and reliable performance. Components are treated to resist corrosion, which extends the lifespan of the heat pump and enhances its efficiency.

The GPH 13 H utilizes innovative inverter technology, allowing it to adjust its cooling and heating output according to the space's specific needs. This results in more consistent temperatures and improved indoor comfort. Additionally, the variable-speed compressor operates at different levels, reducing energy consumption while providing effective heating and cooling.

In terms of installation, the GPH 13 H offers versatility. Its compact design facilitates easy placement in various locations, making it suitable for both new construction and retrofitting existing spaces. The unit's all-in-one design simplifies installation by minimizing the need for external ductwork.

Quiet operation is a critical consideration for many homeowners, and Goodmans excels in this area. The GPH 13 H is engineered to minimize noise levels, ensuring a peaceful indoor environment. This feature makes it an excellent choice for residential areas where noise may be a concern.

The unit also features advanced control systems, including programmable thermostats that allow users to set specific temperature schedules. This feature not only enhances user comfort but also contributes to energy savings by preventing unnecessary heating or cooling when spaces are unoccupied.

Overall, Goodmans Package Heat Pump Units, GPH 13 H, combine efficiency, durability, and advanced technology to deliver a reliable climate control solution. With its focus on energy savings, quiet operation, and flexibility in installation, this model stands out as a leading choice for those seeking optimal home comfort. Its thoughtful design and engineering make it a worthwhile investment in both residential and commercial settings.