Goodmans GPH 13 H, Package Heat Pump Units service manual Package Heat Pump Specifications

Page 25

PACKAGE HEAT PUMP SPECIFICATIONS

 

GPH13[24-36]H41**

MODEL: GPH1324H41*

 

 

EXPANDED PERFORMANCE DATA

HEATING OPERATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor Ambient Temperature

 

 

 

 

 

 

 

 

 

 

 

65

60

55

50

47

45

40

35

30

25

20

17

 

15

10

5

0

-5

-10

 

MBh

27.7

26.2

24.6

23.0

22.0

21.3

19.8

18.3

17.4

16.1

14.8

14.0

 

13.5

12.1

10.7

9.4

8.0

6.5

 

DELTA T

29.3

27.7

26.1

24.4

23.3

22.6

21.0

19.3

18.5

17.0

15.7

14.8

 

14.3

12.8

11.3

9.9

8.4

6.9

 

KW

2.01

1.97

1.94

1.90

1.88

1.86

1.82

1.78

1.82

1.78

1.74

1.72

 

1.70

1.66

1.62

1.58

1.54

1.50

 

AMPS

9.6

9.0

8.5

8.1

7.8

7.7

7.3

7.0

6.7

6.5

6.2

6.1

 

6.0

5.8

5.5

5.2

4.9

4.5

 

COP

4.02

3.88

3.73

3.55

3.43

3.36

3.18

3.00

2.81

2.65

2.50

2.39

 

2.32

2.13

1.94

1.73

1.52

1.28

 

EER

13.7

13.3

12.7

12.1

11.7

11.5

10.9

10.2

9.6

9.1

8.5

8.2

 

7.9

7.3

6.6

5.9

5.2

4.4

 

HI PR

366

351

337

323

315

309

297

285

273

261

251

245

 

240

231

222

213

205

198

 

LO PR

132

122

114

105

99

95

88

78

70

63

55

51

 

50

42

36

31

27

21

Above information is for nominal CFM and 70 degree indoor dry bulb. Instantaneous capacity listed.

MODEL: GPH1330H41A*

 

 

 

 

 

 

 

 

 

 

 

HEATING OPERATION

 

 

 

 

 

 

 

 

Outdoor Ambient Temperature

 

 

 

 

 

 

 

 

 

 

65

60

55

50

47

45

40

35

30

25

20

17

15

10

5

0

-5

-10

 

MBh

33.9

32.1

30.2

28.3

27.0

26.2

24.3

22.4

19.8

18.2

16.8

15.9

15.3

13.7

12.1

10.6

9.0

7.4

 

DELTA T

29.9

28.3

26.7

24.9

23.8

23.1

21.4

19.8

17.4

16.1

14.8

14.0

13.5

12.1

10.7

9.3

8.0

6.5

 

KW

2.43

2.39

2.34

2.29

2.27

2.25

2.20

2.16

2.50

2.44

2.38

2.35

2.33

2.27

2.21

2.16

2.10

2.04

 

AMPS

12.1

11.3

10.7

10.1

9.8

9.6

9.2

8.8

8.5

8.1

7.8

7.7

7.6

7.2

6.9

6.5

6.1

5.7

 

COP

4.08

3.94

3.78

3.61

3.49

3.41

3.23

3.04

2.32

2.19

2.06

1.98

1.92

1.77

1.61

1.44

1.26

1.06

 

EER

14.0

13.5

12.9

12.3

11.9

11.6

11.0

10.4

7.9

7.5

7.0

6.7

6.6

6.0

5.5

4.9

4.3

3.6

 

HI PR

384

368

354

338

331

324

312

299

287

274

263

256

252

242

233

223

215

208

 

LO PR

132

122

115

105

99

96

88

78

71

63

55

52

50

42

36

31

27

21

Above information is for nominal CFM and 70 degree indoor dry bulb. Instantaneous capacity listed.

MODEL: GPH1336H41A*

 

 

 

 

 

 

 

 

 

 

 

HEATING OPERATION

 

 

 

 

 

 

 

 

Outdoor Ambient Temperature

 

 

 

 

 

 

 

 

 

 

65

60

55

50

47

45

40

35

30

25

20

17

15

10

5

0

-5

-10

 

MBh

42.2

40.0

37.6

35.2

33.6

32.6

30.2

27.9

22.4

20.7

19.1

18.0

17.3

15.6

13.8

12.0

10.3

8.4

 

DELTA T

32.6

30.9

29.0

27.1

25.9

25.1

23.3

21.5

17.3

16.0

14.7

13.9

13.4

12.0

10.6

9.3

7.9

6.5

 

KW

2.99

2.94

2.88

2.82

2.79

2.77

2.72

2.66

2.76

2.70

2.64

2.61

2.58

2.52

2.47

2.41

2.35

2.29

 

AMPS

14.8

13.9

13.1

12.5

12.1

11.9

11.3

10.8

10.5

10.1

9.7

9.5

9.4

9.0

8.6

8.2

7.7

7.1

 

COP

4.13

3.99

3.82

3.64

3.52

3.44

3.26

3.07

2.38

2.24

2.11

2.02

1.96

1.80

1.64

1.46

1.28

1.07

 

EER

14.1

13.6

13.1

12.5

12.0

11.8

11.1

10.5

8.1

7.7

7.2

6.9

6.7

6.2

5.6

5.0

4.4

3.7

 

HI PR

368

353

339

324

317

311

299

287

274

262

252

246

241

232

223

214

206

199

 

LO PR

134

125

117

107

101

97

90

80

72

64

57

53

51

43

37

31

27

21

Above information is for nominal CFM and 70 degree indoor dry bulb. Instantaneous capacity listed.

MODEL: GPH1342H41A*

 

 

 

 

 

 

 

 

 

 

 

HEATING OPERATION

 

 

 

 

 

 

 

 

Outdoor Ambient Temperature

 

 

 

 

 

 

 

 

 

 

65

60

55

50

47

45

40

35

30

25

20

17

15

10

5

0

-5

-10

 

MBh

47.8

45.2

42.6

39.8

38.0

36.8

34.2

31.5

27.4

25.3

23.3

22.0

21.2

19.0

16.9

14.7

12.5

10.3

 

DELTA T

31.4

29.7

27.9

26.1

25.0

24.2

22.5

20.7

18.0

16.6

15.3

14.4

13.9

12.5

11.1

9.7

8.2

6.7

 

KW

3.27

3.21

3.15

3.09

3.06

3.04

2.98

2.92

3.03

2.97

2.90

2.87

2.84

2.78

2.71

2.65

2.59

2.53

 

AMPS

11.9

11.2

10.7

10.2

9.9

9.8

9.4

9.0

8.8

8.5

8.2

8.1

8.0

7.8

7.4

7.1

6.8

6.4

 

COP

4.27

4.12

3.95

3.76

3.63

3.55

3.36

3.16

2.65

2.50

2.35

2.25

2.18

2.00

1.82

1.62

1.42

1.19

 

EER

14.6

14.1

13.5

12.9

12.4

12.1

11.5

10.8

9.0

8.5

8.0

7.7

7.5

6.8

6.2

5.5

4.8

4.1

 

HI PR

355

341

327

313

306

300

288

277

265

253

243

237

233

224

216

207

199

192

 

LO PR

130

121

113

104

98

94

87

77

70

62

55

51

49

41

36

30

26

21

Above information is for nominal CFM and 70 degree indoor dry bulb. Instantaneous capacity listed.

25

Image 25
Contents Technical Manual Goodman will not be responsible Product IdentificationFor any injury or property damage Do not connect or use any device Product Design Outside Slab Installation Horizontal HRooftop Installation Horizontal H Minimum Circuit Maximum Electrical Data *Blower Only, Heat ModeOvercurrent Ampacity Protection ampsGPH1324-60H41 Product DimensionsGPH1324-36H41AB GPH1336H41AC Package Heat Pump SpecificationsGPH1342H41AB GPH1348-60H41BB Part Number Description AccessoriesGPH1324-60H41 Blower Performance DataFormulas Performance DataGPH1324H41 Cooling Performance Data105 115 Entering Indoor Wet 13824.0 105 115 Entering Indoor Wet Bulb Temperature105 115 GPH1330H41Airflow 26.111.2 28.2412 15132.4 GPH1336H41149 35.037.5 GPH1342H4140.5 Outdoor Ambient Temperature 105 11515.8 39242.6 GPH1348H4146.0 GPH1360H41 21.1 57.5388 Package Heat Pump Specifications GPH1342-60H41 GPH1324, 30, 42H41AB / GPH1336H41AC GPH1348H41BB Wiring DiagramsBefore Servicing Sources MAY be Property Damage GPH1360H41BB

GPH 13 H, Package Heat Pump Units specifications

Goodmans Package Heat Pump Units, specifically the GPH 13 H model, represent an advanced solution in residential and commercial climate control. Known for their efficiency and reliability, these heat pumps offer a combination of heating and cooling capabilities, making them ideal for year-round comfort.

One of the standout features of the GPH 13 H is its energy efficiency rating. With a SEER (Seasonal Energy Efficiency Ratio) of 13, it efficiently converts energy into heating and cooling, which can lead to significant savings on utility bills. This efficiency is not only beneficial for homeowners looking to reduce their energy footprint, but it also qualifies for many energy rebate programs.

Durability is another hallmark of the GPH 13 H. Built with robust materials, the unit is designed to withstand various weather conditions, ensuring longevity and reliable performance. Components are treated to resist corrosion, which extends the lifespan of the heat pump and enhances its efficiency.

The GPH 13 H utilizes innovative inverter technology, allowing it to adjust its cooling and heating output according to the space's specific needs. This results in more consistent temperatures and improved indoor comfort. Additionally, the variable-speed compressor operates at different levels, reducing energy consumption while providing effective heating and cooling.

In terms of installation, the GPH 13 H offers versatility. Its compact design facilitates easy placement in various locations, making it suitable for both new construction and retrofitting existing spaces. The unit's all-in-one design simplifies installation by minimizing the need for external ductwork.

Quiet operation is a critical consideration for many homeowners, and Goodmans excels in this area. The GPH 13 H is engineered to minimize noise levels, ensuring a peaceful indoor environment. This feature makes it an excellent choice for residential areas where noise may be a concern.

The unit also features advanced control systems, including programmable thermostats that allow users to set specific temperature schedules. This feature not only enhances user comfort but also contributes to energy savings by preventing unnecessary heating or cooling when spaces are unoccupied.

Overall, Goodmans Package Heat Pump Units, GPH 13 H, combine efficiency, durability, and advanced technology to deliver a reliable climate control solution. With its focus on energy savings, quiet operation, and flexibility in installation, this model stands out as a leading choice for those seeking optimal home comfort. Its thoughtful design and engineering make it a worthwhile investment in both residential and commercial settings.