Amana 10730418 installation instructions Maintenance, Accessories

Page 8

OPERATING INSTRUCTIONS

1.Turn on the electrical power supply to the unit.

2.Place the room thermostat selector switch in the COOL or HEAT position (or AUTO if available, and if automatic changeover from cooling to heating is desired).

3.Set the room thermostat to the desired temperature.

MAINTENANCE

WARNING

TO AVOID PERSONAL INJURY OR DEATH DUE TO ELECTRICAL SHOCK, DISCONNECT ELECTRICAL POWER BEFORE PERFORMAING ANY MAINTENANCE.

REPLACING OR CLEANING FILTER

A return air filter is not supplied with this unit; however, there must be a means of filtering all of the return air. The filter(s) may be located in the return air duct(s), or return air filter grille(s). Consult with your installing dealer for the actual location of the return air filter(s) for your unit.

Dirty filters are the most common cause of inadequate heating or cooling performance. Filter inspection should be made at least ev- ery two months; more often if necessary because of local conditions and usage.

Dirty throwaway filters should be discarded and replaced with a new, clean filter. Dirty permanent filters should be washed with water, thor- oughly dried and sprayed with a filter adhesive before being rein- stalled. (Filter adhesives may be found at many hardware stores.) Permanent filters should last several years; however, should one become torn or uncleanable, it should be replaced.

MAINTAINING CABINET FINISH

Use a fine grade automotive wax on the cabinet finish to maintain the finish’s original high luster. This is especially important in areas with high ultraviolet radiation.

CLEAN OUTSIDE COIL (QUALIFIED SERVICER ONLY)

The coil with the outside air flowing over it should be inspected an- nually and cleaned as frequently as necessary to keep the finned areas free of lint, hair and debris.

CONDENSER AND EVAPORATOR MOTORS

Bearings on the evaporator motor and the condenser motor are per- manently lubricated. No additional oiling is required.

WARNING

TO AVOID PERSONAL INJURY OR DEATH DUE TO ELECTRICAL SHOCK, DO NOT REMOVE ANY INTERNAL COMPARTMENT COVERS OR ATTEMPT ANY ADJUSTMENT.

ACCESSORIES

Horizontal Duct Covers (CHK001A)

Single Point Power Connection (SPK**A)

Roof Curb - Heat Pump (PRC06A1)

Roof Curb - Universal (PRC08A1)

Over-Under to Side by Side (PDTROU6A)

Additional accessories, as described above, can be purchased to fit specific application needs. Accessories can be ordered by the part numbers in the table and each accessory includes its own separate instructions.

REPLACEMENT PARTS

Refer to the description in the Parts Catalog when ordering any part. Be sure to provide the unit model, manufacturing, and serial num- bers with the order.

NOTE: Details for installing and wiring electric heater kits and single point wiring kits are contained in the installation instructions for these accessories.

CAUTION

VERIFY PROPER OPERATION AFTER SERVICING.

8

2000-2004 Goodman Company, L.P. Effective: May 2004

Image 8
Contents Package Heat Pump Installation Instructions Safety Instructions Recognize Safety SYMBOLS, WORDS, and LabelsGeneral Information Rigging and HandlingHorizontal Airflow Installations Thermostat PlacementThermostat Wiring Duct ConnectionsFlexible Wiring Setup Circulating AIR and FiltersUnit Voltage Downshot Airflow ConversionHorizontal Duct Cover Installation PHD48/60 and PHB60 ModelsCondensate Drain Startup and AdjustmentNormalsequenceofoperation Maintenance Accessories

10730418 specifications

The Amana 10730418 is a prominent appliance within the realm of home cooling solutions, specifically designed to enhance indoor air quality and comfort. This model exemplifies the blend of modern technology and practical functionality. One of its primary features is the inclusion of a robust cooling system, which effectively regulates temperature, ensuring a consistent and comfortable environment.

A standout aspect of the Amana 10730418 is its advanced energy efficiency. Equipped with a high Seasonal Energy Efficiency Ratio (SEER) rating, this model promises lower energy consumption without compromising cooling performance. This not only translates to reduced utility bills but also reinforces a commitment to environmental sustainability. The incorporation of energy-efficient technologies makes it a wise choice for discerning homeowners focused on minimizing their ecological footprint.

The cooling unit is integrated with a multi-speed fan that provides customizable airflow options, allowing users to select the perfect setting to suit their immediate needs. Whether one desires a gentle breeze or a powerful blast of cool air, the Amana 10730418 can easily adapt, ensuring comfort during any season. Additionally, the unit features a quiet operation mode designed to minimize noise, thereby enhancing the overall living experience.

In terms of control, the Amana 10730418 includes a user-friendly interface that simplifies operation. Many models come with programmable thermostats, allowing users to schedule cooling cycles in advance, ultimately saving energy during those times when cooling is not needed. This feature is particularly handy for busy households, enabling automated adjustments that align with daily routines.

The durability of the Amana 10730418 should also be noted. Constructed with high-quality materials and designed for long-term reliability, this appliance is built to withstand the rigors of daily use. Maintenance is made easier through features like removable filters that can be cleaned or replaced as needed, ensuring optimal performance over an extended lifespan.

Overall, the Amana 10730418 stands out as a comprehensive solution for anyone seeking to enhance their home's climate control systems. Its combination of energy efficiency, customizable performance, and user-friendly features make it an ideal choice for modern living. With this appliance, homeowners can confidently achieve a comfortable, efficient, and enjoyable indoor environment.