Amana 10730418 Duct Connections, Horizontal Airflow Installations, Thermostat Placement

Page 4

Figure 1 - Rigging

DUCT CONNECTIONS

To ensure proper operation, ensure the blower motor is oriented as shown in Figure 5 for horizontal airflow installations.

HORIZONTAL AIRFLOW INSTALLATIONS

(24, 30, 36, 42 AND PHB48 MODELS)

Two three-inch collar connections and two square flanges are shipped with the unit. The collar connections are located in the return air opening of the unit. The square flanges are inside the unit blower compartment. The square flanges can be used for either connect- ing 16x16 ductwork to the unit or used with a Horizontal Duct Cover kit (CHK001A).

To install the collar connections, remove the two collars, reverse and snap them back into place in the outlet and inlet openings. Be sure the flanges are to the outside of the unit. Secure with screws pro- vided.

HORIZONTAL AIRFLOW INSTALLATIONS

(PHD48/60 and PHB60 models only)

These units are equipped with 14x14 square supply and return air openings for horizontal air flow. The openings are flanged for ease of duct connection. A 16x16 Horizontal Duct Cover kit (CHK001A) can be used with the clips provided with the unit.

THERMOSTAT PLACEMENT

Thermostat should be mounted 5 feet above the floor, on a vibration free inside wall in a room or a hallway that has good air circulation. Movement of air should not be obstructed by furniture, door, draper- ies, etc. The thermostat should not be mounted where it will be af- fected by drafts, hot or cold water pipes or air ducts in walls, radiant heat from fireplace, lamps, the sun, television, etc. Consult the In- struction Sheet packaged with thermostat for mounting instructions.

WARNING

TO AVOID PERSONAL INJURY OR DEATH, DISCONNECT THE ELECTRICAL POWER BEFORE ELECTRICALLY CONNECTING THE UNIT.

THERMOSTAT WIRING

When an electric heater is installed, the thermostat wiring will be made at the heater accessory box.

If a unit is installed without electric heaters, the low voltage wiring to the blower section can be cut, either in the control box area or in the blower section, to allow splicing-in of field-installed wiring, or con- nect to terminal strip in unit control box.

See the unit wiring diagram for electrical connections.

ROOM THERMOSTAT

 

 

C/X

G

Y

R

O

W1

W2

E

 

 

 

 

OUTDOOR UNIT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C/X

G

Y

R

O

W

W1

W2

 

 

 

 

PH__C02E

Wiring shown is for D9945804 (THSMEC1H2BA) thermostat.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ROOM THERMOSTAT

 

 

C/X

 

G

 

Y

 

R

 

O

 

 

 

W2

 

E

 

 

OUTDOOR UNIT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C/X

 

G

 

Y

 

R

 

O

W

 

W1

 

W2

 

 

PH__C02E

 

 

 

Wiring shown is for 10636701(THSADC1H2BA) or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10636702 (THSMDC1H2BA) thermostat

 

 

 

 

 

 

 

PHD60 TWO-STAGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yellow No. 20 Wire in Blower Section

 

 

ROOM THERMOSTAT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

G

 

Y2

 

Y1

 

R

O

 

W1

W2

W3

OUTDOOR UNIT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C/X

 

G

 

 

 

 

Y

 

R

O

 

W

W1

W2

PHD60C02E

 

 

 

 

 

 

 

 

 

Wiring shown is for

 

 

 

 

 

 

 

 

 

 

(HEATER KIT CONTROL BOX)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1213412 (1F95-371) thermostat.

 

NOTE: If Electric Heater Kit is not installed or low voltage connection is made in unit control box, connect as follows.

ROOM THERMOSTAT

C

G

Y2

Y1

R

O

W1 W2 W3

 

OUTDOOR UNIT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

G

Y

Y1

R

O

W

 

 

PHD60C02E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(CONTROL BOX)

 

 

 

 

Wiring shown is for 1213412 (1F95-371) thermostat.

Figure 2 - Typical Thermostat and

Unit 24 Volt Wiring Hoo2kup

ELECTRICAL CONNECTIONS

NOTE: The units are designed for operation on 60 Hz current and at the voltages shown on the rating plate. All internal wiring in the unit is complete. The power supply may be brought into the contactor (refer to unit wiring diagram supplied with unit). Ensure 24 volt wiring is connected between the unit control panel and the room thermostat. Refer to Figure 2 for proper thermostat wiring and Figures 3 and 4 shows the low voltage field connection.

Low Voltage

Terminal Strip

C

 

G

 

Y

 

R

 

W

 

W1

ON

W2

ON

O

Figure 3 - Low Voltage Connection

Heater Kit Control Box

4

Image 4
Contents Package Heat Pump Installation Instructions Safety Instructions Recognize Safety SYMBOLS, WORDS, and LabelsGeneral Information Rigging and HandlingHorizontal Airflow Installations Thermostat PlacementThermostat Wiring Duct ConnectionsFlexible Wiring Setup Circulating AIR and FiltersUnit Voltage Downshot Airflow ConversionHorizontal Duct Cover Installation PHD48/60 and PHB60 ModelsNormalsequenceofoperation Startup and AdjustmentCondensate Drain Maintenance Accessories

10730418 specifications

The Amana 10730418 is a prominent appliance within the realm of home cooling solutions, specifically designed to enhance indoor air quality and comfort. This model exemplifies the blend of modern technology and practical functionality. One of its primary features is the inclusion of a robust cooling system, which effectively regulates temperature, ensuring a consistent and comfortable environment.

A standout aspect of the Amana 10730418 is its advanced energy efficiency. Equipped with a high Seasonal Energy Efficiency Ratio (SEER) rating, this model promises lower energy consumption without compromising cooling performance. This not only translates to reduced utility bills but also reinforces a commitment to environmental sustainability. The incorporation of energy-efficient technologies makes it a wise choice for discerning homeowners focused on minimizing their ecological footprint.

The cooling unit is integrated with a multi-speed fan that provides customizable airflow options, allowing users to select the perfect setting to suit their immediate needs. Whether one desires a gentle breeze or a powerful blast of cool air, the Amana 10730418 can easily adapt, ensuring comfort during any season. Additionally, the unit features a quiet operation mode designed to minimize noise, thereby enhancing the overall living experience.

In terms of control, the Amana 10730418 includes a user-friendly interface that simplifies operation. Many models come with programmable thermostats, allowing users to schedule cooling cycles in advance, ultimately saving energy during those times when cooling is not needed. This feature is particularly handy for busy households, enabling automated adjustments that align with daily routines.

The durability of the Amana 10730418 should also be noted. Constructed with high-quality materials and designed for long-term reliability, this appliance is built to withstand the rigors of daily use. Maintenance is made easier through features like removable filters that can be cleaned or replaced as needed, ensuring optimal performance over an extended lifespan.

Overall, the Amana 10730418 stands out as a comprehensive solution for anyone seeking to enhance their home's climate control systems. Its combination of energy efficiency, customizable performance, and user-friendly features make it an ideal choice for modern living. With this appliance, homeowners can confidently achieve a comfortable, efficient, and enjoyable indoor environment.