Amana 10730418 Circulating AIR and Filters, Flexible Wiring Setup, Unit Voltage

Page 5

Low Voltage

Terminal Strip

Figure 4 - Low Voltage Connection

Unit Control Box

Refer to the unit wiring diagram for electrical connections. When installed, the unit must be electrically grounded in accordance with local codes or in the absence of local codes, with the National Elec- trical Code, ANSI/NFPA No. 70, and/or the CSA C22.1 Electrical Code, if an external source is utilized.

WARNING

TO AVOID PERSONAL INJURY OR DEATH DUE TO ELECTRIC SHOCK, WIRING MUST BE PROPERLY GROUNDED.

CAUTION

TO AVOID PROPERTY DAMAGE OR PERSONAL INJURY DUE TO FIRE, USE ONLY COPPER CONDUCTORS.

CAUTION

TO PREVENT IMPROPER AND DANGEROUS OPERATION DUE TO WIRING ERRORS, LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. VERIFY PROPER OPERATION AFTER SERVICING.

The best protection for the wiring is the lowest rated fuse or circuit breaker which will supply power to the unit during normal operation without nuisance trips. Such a device will provide maximum circuit protection. DO NOT EXCEED THE MAXIMUM OVERCURRENT DEVICE SIZE SHOWN ON UNIT DATA PLATE.

All line voltage connections must be made through weatherproof fittings. All exterior power supply and ground wiring must be in ap- proved weatherproof conduit. Low voltage wiring from the unit con- trol panel to the thermostat requires coded cable.

FLEXIBLE WIRING SETUP

Line and low voltage wiring can enter the unit from either side.

REAR VIEW

ELECTRICAL

SUPPLY RETURN

AIRAIR

UNIT VOLTAGE

The unit transformer is factory connected for 230V operation. If the unit is to operate on 208V, reconnect the transformer primary lead as shown on the unit wiring diagram.

CIRCULATING AIR AND FILTERS

DOWNSHOT AIRFLOW CONVERSION

Units are shipped from the factory ready for horizontal airflow. These units can be easily converted from horizontal to downshot airflow delivery. If conversion to vertical airflow is necessary, proceed as follows:

BLOWER ROTATION

The first step in the conversion is to rotate the blower assembly for downshot airflow. After rotating the blower assembly, the blower motor must be oriented as shown in Figure 7 with the motor wires at the bottom. This keeps condensate from puddling inside the blower motor and causing motor failure. If the motor is not oriented correctly, loosen the motor belly band and rotate the motor to the correct position, then retighten the motor belly band.

1.Cut insulation around bottom openings and remove panels from the bottom of the unit, saving the screws holding the panels in place.

2.From the rear of the unit, remove the four screws securing the blower assembly in place and loosen the two screws directly below the duct opening (Figure 5).

Remove

Loosen

Figure 5 - Duct Removal

3.Remove the clamp securing the blower assembly to the bottom of the unit. The clamp and screws may be discarded (Figure 6).

{ } Airflow

SIDE VIEW

 

SIDE VIEW

 

 

 

 

HEATER

ELECTRICAL

ELECT.

 

KIT

 

 

 

BLOWER

LOW

CONTROL

COMPRESSOR

BOX

 

VOLTAGE

EVAP

 

 

 

 

 

 

COIL

 

For knockout locations, see dimension drawing in the Product Data Book applicable to your model* . Use the Single Point wiring kit to add further flexibility to the installation wiring.

Remove

Figure 6 - Clamp Removal

4.Rotate the blower assembly 90° clockwise, setting the blower assembly outlet on the bottom of the unit and secure with two screws removed in step 2 (Figure 7) .

5.Tighten the two screws below the duct opening that were loosened in step 2.

NOTE: To keep condensate from collecting inside the blower motor, ensure the motor is oriented with its leads exiting at the bottom of the motor (Figures 5 and 6).

5

Image 5
Contents Package Heat Pump Installation Instructions Recognize Safety SYMBOLS, WORDS, and Labels Safety InstructionsRigging and Handling General InformationThermostat Placement Horizontal Airflow InstallationsThermostat Wiring Duct ConnectionsCirculating AIR and Filters Flexible Wiring SetupUnit Voltage Downshot Airflow ConversionPHD48/60 and PHB60 Models Horizontal Duct Cover InstallationCondensate Drain Startup and AdjustmentNormalsequenceofoperation Accessories Maintenance

10730418 specifications

The Amana 10730418 is a prominent appliance within the realm of home cooling solutions, specifically designed to enhance indoor air quality and comfort. This model exemplifies the blend of modern technology and practical functionality. One of its primary features is the inclusion of a robust cooling system, which effectively regulates temperature, ensuring a consistent and comfortable environment.

A standout aspect of the Amana 10730418 is its advanced energy efficiency. Equipped with a high Seasonal Energy Efficiency Ratio (SEER) rating, this model promises lower energy consumption without compromising cooling performance. This not only translates to reduced utility bills but also reinforces a commitment to environmental sustainability. The incorporation of energy-efficient technologies makes it a wise choice for discerning homeowners focused on minimizing their ecological footprint.

The cooling unit is integrated with a multi-speed fan that provides customizable airflow options, allowing users to select the perfect setting to suit their immediate needs. Whether one desires a gentle breeze or a powerful blast of cool air, the Amana 10730418 can easily adapt, ensuring comfort during any season. Additionally, the unit features a quiet operation mode designed to minimize noise, thereby enhancing the overall living experience.

In terms of control, the Amana 10730418 includes a user-friendly interface that simplifies operation. Many models come with programmable thermostats, allowing users to schedule cooling cycles in advance, ultimately saving energy during those times when cooling is not needed. This feature is particularly handy for busy households, enabling automated adjustments that align with daily routines.

The durability of the Amana 10730418 should also be noted. Constructed with high-quality materials and designed for long-term reliability, this appliance is built to withstand the rigors of daily use. Maintenance is made easier through features like removable filters that can be cleaned or replaced as needed, ensuring optimal performance over an extended lifespan.

Overall, the Amana 10730418 stands out as a comprehensive solution for anyone seeking to enhance their home's climate control systems. Its combination of energy efficiency, customizable performance, and user-friendly features make it an ideal choice for modern living. With this appliance, homeowners can confidently achieve a comfortable, efficient, and enjoyable indoor environment.