Note: Your Linux operating system may not support SES but the SES | |
functions are used when running the standalone AIX Diagnostic CD. | |
Attention: The SCSI address of the SCSI attachment that is connected to the | |
2104 must be different from the addresses of the installed disk drive modules. | |
When a second SCSI attachment is connected to a 2104, the SCSI address of | |
that SCSI attachment must be different from the address of the first SCSI | |
attachment and different from the addresses of the installed disk drive | |
modules. | |
| 12. The 2104 Orientation switch 2 configures the Power and Check lights that |
| are on the front of the 2104. Ensure that this switch is set to Off so that the |
| lights are correct for your 2104 Model DU3. |
| 13. The SCSI Bus Split switch 3 controls the SCSI bus configuration of your |
| 2104. When the switch is set to Off, the 2104 is configured in single SCSI bus |
| mode. When the switch is set to On, the 2104 is configured in dual SCSI bus |
| (split bus) mode. |
When a 2104 Model DU3 is in dual SCSI bus mode, the SCSI addresses of | |
one SCSI bus are 0 through 6, from left to center, and the SCSI addresses of | |
the other SCSI bus are 8 through 14, from center to right. | |
Refer to the 2104 configuration information, and set the SCSI Bus Split switch | |
3 as required. | |
| 14. Switch 4 is reserved. Ensure that is it set to Off. |
Installing a 2104 Model DU3 25