Chapter 4: Operation
4-1 Start-up
1.Turn the power switch ON.
2.Set the desired feed rate on the RPM display using the up or down arrows.
3.Flip the motor switch to AUTO.
If the additive feeder is installed correcly, it should begin operation at the desired RPM when the processing machine screw is in operation.
4-2 Controller Description and Operation
Identifying Control Panel Indicator Lights and Switches on the Controller
Switches
Power Switch. This switch turns the control ON and OFF.
Motor Switch. This switch has three (3) positions:
•OFF stops the auger motor.
•AUTO starts normal automatic operation.
•MANUAL operates the auger at the set point as long as the switch is held in this position. Use this feature when calibrating the feeder or during cleanout.
Indicator Lights
Motor Light. This indicator lights when the auger motor is turning.
Auger Speed. This LED displays the auger speed setpoint.
Additive Feeders | Chapter 4: Operation | 22 of 50 |