Sterling 882.00274.00 specifications Additive Feeders Troubleshooting

Models: 882.00274.00

1 51
Download 51 pages 51.35 Kb
Page 38
Image 38

 

Problem

 

Possible cause

 

Corrective action

 

 

 

 

 

 

 

 

 

Field contact jumper (J1) has not

 

Remove jumper and wire the

 

 

 

 

terminals to the processing

 

 

 

been removed. AUTO MODE.

 

 

 

 

 

machine relay.

 

 

 

 

 

 

 

 

Field contact to the processing

 

Check wiring/check the relay on

 

 

 

machine has failed.

 

the processor.

 

Motor will not stop.

 

Motor switch has failed.

 

Replace.

 

 

Field contact to process machine

 

Correct.

 

 

 

 

 

 

 

missing or loose.

 

 

 

 

 

 

 

 

 

Control relay has failed.

 

Replace.

 

 

 

Motor control has failed.

 

Replace.

 

 

 

Optional timer set incorrectly.

 

Reset.

 

 

 

Optional timer has failed.

 

Replace.

 

 

 

Signal from motor speed sensor

 

Secure the sensor connections.

 

 

 

missing.

 

 

Motor runs only at maximum

 

 

 

 

 

Motor control has failed.

 

Replace.

 

speed.

 

Motor speed sensor has failed.

 

Replace.

 

 

 

Motor speed sensor magnet

 

Adjust.

 

 

 

misaligned.

 

 

 

 

 

 

 

 

 

Intermittent signal from motor

 

Secure the sensor connections.

 

 

 

speed sensor.

 

 

Motor speed not constant.

 

 

 

 

 

Motor speed sensor has failed.

 

Replace.

 

 

 

Motor control has failed.

 

Replace.

 

 

 

Material flow problem.

 

Inspect for blockage, etc.

 

Additive is contaminated by

 

Feeder was not cleaned

 

See Section 5-2 on Page 34 for

 

color from previous run.

 

adequately prior to operation.

 

cleanout instructions.

Other service problems or questions can be answered by contacting the Service Department.