Additive Feeder Control Factory Defaults

WARNING! This procedure involves resetting a DIP switch within a live electrical enclosure. Only persons with the proper knowledge of and respect for working on energized electrical devices should attempt this procedure. Use extreme caution!

Note: Set the decimal point with DIP switch 4 first to avoid confusion when keying in the presets; for example, 300 and 30.0.

Figure 4: Additive Feeder Control Factory Defaults

DIP

Variable

Pre-set

Switch 1

Auger RPM Constant

30.0

Switch 2

Program Minimum

0.0

Switch 3

Program Maximum

70.0

Switch 4

Decimal Place

0.3

Switch 5

Master/Follower Select

OFF

 

Standard Control

 

Optional Extruder

 

 

Tracking Control

ON

4-3 Shutting Down the Additive Feeder

1.Flip the motor switch to the OFF (center) position.

2.Turn the power OFF.

For long term shutdown, disconnect power and clean the additive feeder.