Friedrich RAC-SVC-06 service manual 08 L 1, Unit Identification

Page 5

UNIT IDENTIFICATION

Model Number Code

S S 08 L 1 0

1st Digit – Function

S = Straight Cool, Value Series

Y = Heat Pump

E = Electric Heat

K = Straight Cool

R = Straight Cool

X = Straight Cool

W = Thru-the Wall,

WallMaster Series

2nd Digit

C = Casement

Q = Q-Star

S = Small Chassis

M = Medium Chassis

L = Large Chassis

H = HazardGard

3rd and 4th Digit - Approximate BTU/HR (Cooling)

Heating BTU/Hr capacity listed in the

Specifi cation/Performance Data Section

A

8th Digit – Engineering

Major change

7th Digit – Options

0 = Straight Cool &

Heat Pump Models

1 = 1 KW Heat Strip, Normal

3 = 3 KW Heat Strip, Normal

4 = 4 KW Heat Strip, Normal

5 = 5 KW Heat Strip, Normal

6th Digit – Voltage

1 = 115 Volts

3 = 230-208 Volts

5th Digit

Alphabetical Modifi er

RAC Serial Number Identification Guide

Serial Number

 

L

C

G

R

00001

Decade Manufactured

 

 

 

 

 

L=0

C=3

F=6

J=9

 

 

 

Production Run Number

A=1

D=4

G=7

 

 

 

 

 

B=2

E=5

H=8

 

 

 

 

 

 

 

 

 

 

 

Year Manufactured

 

 

 

 

Product Line

A=1

D=4

G=7

K=0

 

 

 

R = RAC

B=2

E=5

H=8

 

 

 

 

P = PTAC

C=3

F=6

J=9

 

 

 

 

E = EAC

Month Manufactured

 

 

 

 

V = VPAK

A=Jan

D=Apr

G=Jul

K=Oct

 

 

 

H = Split

B=Feb

E=May

H=Aug

L=Nov

 

 

 

 

C=Mar

F=Jun

J=Sept

M=Dec

 

 

 

 

 

 

 

 

 

 

 

 

5

Image 5
Contents 2006 Introduction Table of ContentsRoom AIR Conditioners Limited Warranty Routine Maintenance Unit Identification 08 L 1Chassis Performance DataReceptacle Electrical DataElectronic Controls Functional Component DefinitionsTesting the Electronic Control Error Code Listings Testing the Electronic Control XQ/WS Boards & QME BoardsSealed Refrigeration System Repairs Refrigeration System Sequence of OperationSpecialprocedureinthecaseofcompressor Motor Burnout Hermetic Component ReplacementRotarycompressorspecialtroubleshooting and Service Equipment RequiredMethod of Charging Refrigerant ChargingOvercharged Refrigerant Systems Undercharged Refrigerant SystemsRestricted Refrigerant System Malfunction of Valve Normal Function of ValveProblem Possible Cause Action Cooling only Room AIR Conditioners Troubleshooting TipsReplace fuse, reset breaker. If repeats, check Problem Possible Cause Action Problem Possible Cause Action Heat / Cool Room AIR Conditioners Troubleshooting Tips Refrigerant System Diagnosis Heating Troubleshooting Chart CoolingElectrical Troubleshooting Chart Heat Pump Troubleshooting Chart HeatingSystem Cools When Heating is Desired YESModel Models RM18L30-A, KM18L30-A, KM21L30-A, RM24L30-A, KM24L30-A SS16L30-A/B, SM18L30-A/B, SM21L30-A/B, SM24L30-A/B SL36L30-A SL28L30-A SL36L30-B EQ08L11-A ES12L33-A, ES16L33-A, EM18L34-A, EM24L35-A EL36L35-A YS09L10-A, YS09L10-B YS13L33-A, YM18L34-A YL24L35-A RAC-Svc-06