Kühl Control Options

The Kühl gives you a variety of options for control, programming, and scheduling including wireless capabilities

Wireless Programming and Control:

.The new FriedrichLink™ Adapter (sold seperately) allows you to conviently control, program and monitor your air conditioning unit remotely from a smartphone or computer.

FriedrichLink™ Adapter accessory available through Friedrich authorized retailers or www.friedrich.com. See FriedrichLink™ Adapter section on www.friedrich.com for complete details.

The “Residential” (40 Hr. Work Week) Schedule has four (4) time periods: 06:00, 08:00, 18:00, and 22:00. This option will cause your Kühl Q unit to raise the room temperature temporarily to 85°F during the hours when most people are away at work, lower them again to 78°F prior to the time when most people will return home, and then raise slightly to 82°F to maintain a comfortable temperature overnight.

The “Commercial” (5-Day Business Week) Schedule has two (2) time periods: 07:00 and 18:00. This option will cause your air conditioner to raise temperatures to 84°F after typical working hours and on weekends when commercial spaces are typically unoccupied.

(See Control Panel Operation Instructions Section)

Pre-Programmed Scheduling Options:

Your unit’s digital control comes equipped with a 24-hour timer and two pre- programmed 7-day energy management options.

24-Hour Timer

The 24-hour timer allows you to turn the unit off and on at pre-set times by setting an on and off time on the unit control panel. (See page 12 for details on timer set-up.)

Pre-programmed Energy Management

Customizable Programming Options:

Customizable schedules, with up to four temperature adjustments per day, can either be uploaded to the unit via the air conditioner’s built-in micro USB interface or conveniently transmitted wirelessly using the new FriedrichLink™ Adapter accessory, greatly simplifying the programming of one or multiple units.

See Figure 9.

See www.friedrich.com for complete Customizable Programming instructions.

Your unit comes from the factory with two (2) Pre-programmed Energy

Management settings are shown in Addendum 1 (Residential & Commercial

Schedule Table).

Energy Management Schedule Options are:

1.Residential Schedule – 40 Hr. Work Week

2.Commercial Schedule – 5-Day Business Week

Figure 9

UL

FriedrichLink™ Adapter

10

Image 10
Contents Room Air Conditioners Standard Chassis ModelsRegister your air conditioner Table of Contents Safety Precautions Your safety and the safety of others are very importantSlide the foam front support forward Unpacking InstructionsStep Carefully lift decorative front box from foam front supportARN I N G Before Operating Your Unit Ake sure the wiring is adequate for your unitTest the power cord Do N OT use an extension cordStandard Filter Cleaning / Installation Instructions Premium Carbon Filter Installation Instructions Control Panel Operation Kühl Control Options FAN only Mode Auto ModeCool Mode Heat ModeContinuous Other FunctionsºF ºC Select DIM FunctionAlerts Lock Control PanelExternal Control Status Timer/Schedule SelectTimer factory default Advanced FunctionsModify the Timer Function Timer Start Time Timer Stop TimeTimer Scheduler Control Block Schedule on ScenariosTimer on Scenarios Scheduler OFF ScenariosTimer OFF Scenarios Remote Control Operation Remote EffectivenessAuto Auto FAN Continuous Remote Thermostat Airflow Selection and AdjustmentAir flow direction adjustment Fresh air and exhaust controlRecommended Tools Installation InstructionsRead this FIRST! Electrical Requirements Installation Hardware and Accessory Detail Standard Window Installation Handle UseTOP View of Unit Detail B-2 Slope Down Support Bracket Item Slope Down Stone Ledge Outside Wall Discard Shaded Area Cut/Sever Section A-A Use Tool Provided Location of Grille Removal ToolCord Routing Change Unplug unitCarefully push electrical control panel back into chassis Through-the-Wall Installation Before Caulk ALL Sides Inside and Outside Cabinet Mortar Point Y Trim Moulding Final Inspection & Start-up Checklist Service and Assistance Routine MaintenanceAvailable Accessories Troubleshooting Tips Unit does not operatePage Addendum Schedule Table with Energy Saving ValuesANY Part Sealed Refrigerant System Applicability and Limitations9300100000
Related manuals
Manual 46 pages 14.38 Kb

SM15, SL 24, SS15, SL 22, YS10 specifications

The Friedrich YS10, SL 22, SS15, SL 24, and SM15 are a series of innovative machines designed for various industrial applications, primarily focusing on precision and efficiency in manufacturing processes. Each model boasts unique features tailored to meet distinct needs across different sectors.

The YS10 stands out with its advanced automation capabilities, enabling enhanced productivity through smart technology integration. It employs a state-of-the-art control system that allows operators to program complex tasks with ease, making it suitable for high-volume production environments. Additionally, the YS10 is equipped with an intuitive user interface that simplifies operation and minimizes training time for new users.

Moving on to the SL 22, this model is recognized for its versatility in handling diverse materials. It incorporates adjustable settings that allow users to switch between various manufacturing processes seamlessly. The SL 22 is also designed for energy efficiency, utilizing cutting-edge motion control technology to reduce power consumption without compromising performance. Its robust construction ensures longevity and reliability, essential for demanding industrial applications.

The SS15 is engineered specifically for precision tasks, featuring high-resolution sensors that guarantee exceptional accuracy in measurements. This model excels in environments where tight tolerances are crucial, such as in electronics and automotive manufacturing. The SS15 also includes advanced software for real-time monitoring and adjustments, ensuring consistent results throughout the production cycle.

On the other hand, the SL 24 offers enhanced speed and throughput capabilities, making it ideal for fast-paced industries. Its high-performance motor system delivers rapid cycle times while maintaining stability and control. The SL 24's modular design allows for easy upgrades and expansions, enabling manufacturers to adapt to changing market demands effectively.

Lastly, the SM15 focuses on simplifying maintenance processes, featuring accessible components that minimize downtime during servicing. This model employs predictive maintenance algorithms that analyze performance data, alerting users to potential issues before they lead to failures. The SM15 is designed with user experience in mind, offering a balance of functionality and ease of use.

Together, the Friedrich YS10, SL 22, SS15, SL 24, and SM15 represent a comprehensive lineup of machinery built for modern industrial challenges. With their advanced features, these machines offer companies the tools they need to enhance productivity, ensure precision, and improve overall operational efficiency.