Lincoln Electric DX450 specifications Figure B.1, Weld Mode Selector Switch

Page 19

B-2

OPERATION

B-2

 

FIGURE B.1

 

 

 

11

 

1

9

 

2

 

 

 

3

10

 

13

 

4

 

14

 

12

 

15

 

 

 

16

8

 

 

 

17

7

 

18

21

 

19

22

 

 

 

20

 

 

5

6

 

 

WELDING CONTROLS (Figure B.1)

1.OUTPUT CONTROL- The OUTPUT dial is used to preset the output voltage or current as dis- played on the digital meters for the five welding modes. When in the CC-STICK, ARC GOUGING or CV-WIRE modes and when a remote control is con- nected to the 3-Pin or 14-Pin Connector, the auto- sensing circuit automatically switches the OUTPUT CONTROL from control at the welder to the remote control.

When in the DOWNHILL PIPE mode and when a remote control is connected to the 3-Pin or 14-Pin connector, the output control is used to set the max- imum current range of the remote.

EXAMPLE: When the OUTPUT CONTROL on the welder is set to 200 amps the current range on the

remote control will be 40-200 amps, rather than the full 40-300 amps. Any current range that is less than the full range provides finer current resolution for more fine tuning of the output.

In the CV-WIRE mode, if the feeder being used has a voltage control when the wire feeder control cable is connected to the 14-Pin Connector, the auto- sensing circuit automatically makes OUTPUT CON- TROL inactive and the wire feeder voltage control active. Otherwise, the OUTPUT CONTROL is used to preset the voltage

When in the TOUCH START TIG mode and when an Amptrol is connected to the 3-Pin Connector, the OUTPUT dial is used to set the maximum current range of the CURRENT CONTROL of the Amptrol.

2. DIGITAL OUTPUT METERS-The digital meters allow the output voltage (CV-WIRE mode) or current (CC-STICK, DOWNHILL PIPE, ARC GOUGING and TIG modes) to be set prior to weld- ing using the OUTPUT control dial. During welding, the meter display the actual output voltage (VOLTS) and current (AMPS). A memory feature holds the display of both meters on for seven sec- onds after welding is stopped. This allows the oper- ator to read the actual current and voltage just prior to when welding was ceased.

While the display is being held the left-most deci- mal point in each display will be flashing. The accuracy of the meters is +/- 3%.

3. WELD MODE SELECTOR SWITCH-

(Provides five selectable welding modes)

CV-WIRE

ARC GOUGING

DOWNHILL PIPE CC-STICK TOUCH START TIG

DX450 (RED-D-ARC)

Image 19
Contents RED-D-ARC DX450 RED-D-ARC SafetyElectric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéCustomer Assistance Policy Thank YouTable of Contents Series Section DSection E Section FTechnical Specifications DX450 K2712-1 InstallationVRD Voltage Reduction Device Safety PrecautionsLocation and Ventilation OIL PRE-OPERATION Engine ServiceVehicle Mounting TowingEngine Cooling System Battery ConnectionRemote Control FuelElectrical Connections Standby Power Connections Auxiliary Power ReceptaclesDuplex Receptacles and Gfci Modules Xyz Connection of DX450 to Premises WiringAcross The-Arc Model Connection of Lincoln Electric Wire FeedersConnection of LN-7 or LN-8 to the DX450 Shut the welder off Connection of LN-15 to the DX450 Shut the welder offInstallation General Description OperationFigure B.1 Weld Mode Selector SwitchTable B.1 Wire Feeder Voltmeter SwitchTable B.2 Engine ControlsGlow Plug Push Button Starting the EngineDuty Cycle Stopping the EngineWelder Operation Constant Current CC-STICK WeldingTypical Current Ranges 1 for Tungsten ELECTRODES2 TIG WeldingTable B.3 Plus Wire WELDING-CVAuxiliary Power ARC GougingTIG Options AccessoriesField Installed Options / Accessories Wire Feeder OptionsRoutine Maintenance MaintenanceEngine OIL Change AIR CleanerOIL Filter Change Servicei Instructions Tightening the FAN Belt Cooling SystemBleeding the Fuel System Battery Maintenance Engine AdjustmentServicing Optional Spark Arrestor Gfci Module Testing and Resetting Procedure Welder / Generator MaintenanceHOW to USE Troubleshooting Guide TroubleshootingContact your local Authorized Field Service FacilityWelding without a control cable High idle does not work Faulty control cable. Repair or Your local Authorized Field Service FacilityDX450 RED-D-ARC DiagramsDiagrams Diagrams Diagrams Diagrams Diagrams DX450 RED-D-ARC Wiring Diagram ARC DimensionPrint DX450 RED-DDX450 RED-D-ARC DX450 RED-D-ARC Precaucion Warnung