Page 24

B-7

OPERATION

B-7

 

 

 

This will keep the "Solid State" contactor open and provide a "cold" electrode until the Amptrol or Arc Start Switch is pressed.

When using the TIG Module, the OUTPUT CONTROL on the DX450 is used to set the maximum range of the CURRENT CONTROL on the TIG Module or an Amptrol if connected to the TIG Module.

NOTE: The TIG process is to receive a low voltage welding process. There is no difference in operation with the VRD “On” or “Off” for this mode. For indicator light oper- ation, see table B.1.

WIRE WELDING-CV

Connect a wire feeder to the DX450 according to the instruc- tions in INSTALLATION INSTRUCTIONS Section.

The DX450 in the CV-WIRE mode, permits it to be used with a broad range of flux cored wire (Innershield and Outershield) electrodes and solid wires for MIG welding (gas metal arc weld- ing). Welding can be finely tuned using the ARC CONTROL. Turning the ARC CONTROL clockwise from –10 (soft) to +10 (crisp) changes the arc from soft and washed-in to crisp and narrow. It acts as an inductance/pinch control. The proper set- ting depends on the procedure and operator preference. Start with the dial set at 0.

NOTE: In the CV-Mode with VRD “On”, the OCV(Open Circuit Voltage) is not reduced. For indicator light operation, see table B.1.

ARC GOUGING

The DX450 can be used for arc gouging. For optimal performance, set the MODE switch to ARC GOUGING. Set the OUTPUT CONTROL knob to adjust output

current to the desired level for the gouging electrode being used according to the ratings in the following Table B.4.

TABLE B.4

Carbon Diameter

Current Range (DC, electrode

 

 

positive)

 

1/8"(3.2mm)

60-90 Amps

 

5/32"(4.0mm)

90-150 Amps

 

3/16"9(4.8mm)

200-250 Amps

 

1/4"(6.4mm)

300-400 Amps

 

5/16"(8.0mm)

400-Max.Amps

 

 

 

The ARC CONTROL is not active in the ARC GOUG- ING Mode. The ARC CONTROL is automatically set to maximum when the ARC GOUGING mode is selected which provides the best ARC GOUGING per- formance.

NOTE: With the VRD switch in the “ON” position there is no output in the Arc Gouging Mode. For indicator light operation, see table B.1.

AUXILIARY POWER:

Start the engine and set the IDLER control switch to the desired operating mode. Full power is available regardless of the welding control settings providing no welding current is being drawn.

Simultaneous Welding and Auxiliary Power Loads

The auxiliary power ratings are with no welding load. Simultaneous welding and power loads are specified in Table B.5.

TABLE B.5 DX450 SIMULTANEOUS WELDING AND POWER LOADS

WELD

 

1 PHASE

 

3 PHASE

 

BOTH 1 AND 3 PHASE

AMPS

 

WATTS

AMPS

 

WATTS

AMPS

 

WATTS

AMPS

0

 

11,000

46

 

17,000

41

 

11,000

-

100

PLUS

11,100

46

OR

15,400

37

OR

11,000

-

200

8,000

33

13,000

31

8,000

-

300

 

4,700

20

 

9,400

23

 

4,700

-

400

 

1,700

7

 

3,400

8

 

1,700

-

500

 

0

0

 

0

0

 

0

0

 

 

 

 

 

 

 

 

 

 

TABLE B.6

DX450 Extension Cord Length Recommendations

(Use the shortest length extension cord possible sized per the following table.)

Current

Voltage

Load

 

 

Maximum Allowable Cord Length in ft. (m) for Conductor Size

 

 

(Amps)

Volts

(Watts)

14 AWG

12 AWG

10 AWG

8 AWG

6 AWG

4 AWG

15

120

1800

30

(9)

40

(12)

75

(23)

125

(38)

175

(53)

300

(91)

20

120

2400

 

 

30

(9)

50

(15)

88

(27)

138

(42)

225

(69)

15

240

3600

60

(18)

75

(23)

150

(46)

225

(69)

350

(107)

600

(183)

20

240

4800

 

 

60

(18)

100

(30)

175

(53)

275

(84)

450

(137)

44

240

9500

 

 

 

 

50

(15)

90

(27)

150

(46)

225

(69)

 

 

 

 

Conductor size is based on maximum 2.0% voltage drop.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DX450 (RED-D-ARC)

Image 24
Contents RED-D-ARC Safety DX450 RED-D-ARCElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcThank You Customer Assistance PolicyTable of Contents Section D Section ESection F SeriesInstallation Technical Specifications DX450 K2712-1Safety Precautions VRD Voltage Reduction DeviceLocation and Ventilation PRE-OPERATION Engine Service Vehicle MountingTowing OILBattery Connection Remote ControlFuel Engine Cooling SystemElectrical Connections Auxiliary Power Receptacles Standby Power ConnectionsDuplex Receptacles and Gfci Modules Connection of DX450 to Premises Wiring XyzConnection of Lincoln Electric Wire Feeders Connection of LN-7 or LN-8 to the DX450 Shut the welder offConnection of LN-15 to the DX450 Shut the welder off Across The-Arc ModelInstallation Operation General DescriptionWeld Mode Selector Switch Figure B.1Wire Feeder Voltmeter Switch Table B.1Engine Controls Glow Plug Push ButtonStarting the Engine Table B.2Stopping the Engine Welder OperationConstant Current CC-STICK Welding Duty CycleTIG Welding Typical Current Ranges 1 for Tungsten ELECTRODES2Table B.3 Wire WELDING-CV Auxiliary PowerARC Gouging PlusAccessories Field Installed Options / AccessoriesWire Feeder Options TIG OptionsMaintenance Routine MaintenanceAIR Cleaner Engine OIL ChangeOIL Filter Change Servicei Instructions Cooling System Tightening the FAN BeltBleeding the Fuel System Engine Adjustment Battery MaintenanceServicing Optional Spark Arrestor Welder / Generator Maintenance Gfci Module Testing and Resetting ProcedureTroubleshooting HOW to USE Troubleshooting GuideField Service Facility Contact your local AuthorizedWelding without a control cable High idle does not work Faulty control cable. Repair or Service Facility Your local Authorized FieldDiagrams DX450 RED-D-ARCDiagrams Diagrams Diagrams Diagrams Diagrams DX450 RED-D-ARC Wiring Diagram Dimension PrintDX450 RED-D ARCDX450 RED-D-ARC DX450 RED-D-ARC Precaucion Warnung