MAINTENANCE

D-5

 

 

 

FUEL FILTER

1.Check the fuel filter and fuel pre-filter for water accumulation or sediment.

2.Replace the fuel filter if it is found with excessive water accumulation or sediment. Empty fuel pre-fil- ter.

OVERSPEED IS HAZARDOUS

The maximum allowable high idle speed for this machine is 1850 RPM, no load. Do NOT tamper with governor components or setting or make any other adjustments to increase the maximum speed. Severe personal injury and damage to the machine can result if operated at speeds above maximum.

ENGINE ADJUSTMENT

Adjustments to the engine are to be made only by a Service Center or an authorized Field Service Shop.

BATTERY MAINTENANCE

To access the battery, remove the battery tray from the front of the machine with 3/8” nut driver or flat head screw driver. Pull the tray out of machine far enough to disconnect the negative and then positive battery cables. The tray can then be tilted and lifted to remove the entire tray and battery from the machine for easy service.

WARNING

GASES FROM BATTERY can explode.

Keep sparks, flame and cigarettes away from battery.

To prevent EXPLOSION when:

INSTALLING A NEW BATTERY — disconnect negative cable from old battery first and con- nect to new battery last.

CONNECTING A BATTERY CHARGER — remove battery from welder by disconnecting negative cable first, then positive cable and battery clamp. When reinstalling, connect negative cable last. Keep well ventilated.

USING A BOOSTER — connect positive lead to battery first then connect negative lead to neg- ative battery lead at engine foot.

BATTERY ACID can burn eyes and skin.

Wear gloves and eye protection and be careful when working near

battery.

Follow instructions printed on bat- tery.

CLEANING THE BATTERY

Keep the battery clean by wiping it with a damp cloth when dirty. If the terminals appear corroded, discon- nect the battery cables and wash the terminals with an ammonia solution or a solution of 1/4 pound (0.1113 kg) of baking soda and 1 quart (0.9461L) of water. Be sure the battery vent plugs (if equipped) are tight so that none of the solution enters the cells.

After cleaning, flush the outside of the battery, the bat- tery compartment, and surrounding areas with clear water. Coat the battery terminals lightly with petroleum jelly or a non-conductive grease to retard corrosion.

Keep the battery clean and dry. Moisture accumula- tion on the battery can lead to more rapid discharge and early battery failure.

CHECKING THE ELECTROLYTE LEVEL

If battery cells are low, fill them to the neck of the filler hole with distilled water and recharge. If one cell is low, check for leaks.

CHARGING THE BATTERY

When you charge, jump, replace, or otherwise con- nect battery cables to the battery, be sure the polarity is correct. Improper polarity can damage the charging circuit. The DX450 positive (+) battery terminal has a red terminal cover.

If you need to charge the battery with an external charger, disconnect the negative cable first, then the positive cable before you attach the charger leads. After the battery is charged, reconnect the positive battery cable first and the negative cable last. Failure to do so can result in damage to the internal charger components.

Follow the instructions of the battery charger manu- facturer for proper charger settings and charging time.

SERVICING OPTIONAL SPARK ARRESTOR

Clean every 100 hours.

WARNING

MUFFLER MAY BE HOT

ALLOW ENGINE TO COOL BEFORE INSTALLING

THE SPARK ARRESTER!

DO NOT OPERATE ENGINE WHILE INSTALLING THE SPARK ARRESTER!

DX450 (RED-D-ARC)

Image 30
Contents RED-D-ARC Safety DX450 RED-D-ARCElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcThank You Customer Assistance PolicyTable of Contents Section F Section DSection E SeriesInstallation Technical Specifications DX450 K2712-1Safety Precautions VRD Voltage Reduction DeviceLocation and Ventilation Towing PRE-OPERATION Engine ServiceVehicle Mounting OILFuel Battery ConnectionRemote Control Engine Cooling SystemElectrical Connections Auxiliary Power Receptacles Standby Power ConnectionsDuplex Receptacles and Gfci Modules Connection of DX450 to Premises Wiring XyzConnection of LN-15 to the DX450 Shut the welder off Connection of Lincoln Electric Wire FeedersConnection of LN-7 or LN-8 to the DX450 Shut the welder off Across The-Arc ModelInstallation Operation General DescriptionWeld Mode Selector Switch Figure B.1Wire Feeder Voltmeter Switch Table B.1Starting the Engine Engine ControlsGlow Plug Push Button Table B.2Constant Current CC-STICK Welding Stopping the EngineWelder Operation Duty CycleTIG Welding Typical Current Ranges 1 for Tungsten ELECTRODES2Table B.3 ARC Gouging Wire WELDING-CVAuxiliary Power PlusWire Feeder Options AccessoriesField Installed Options / Accessories TIG OptionsMaintenance Routine MaintenanceAIR Cleaner Engine OIL ChangeOIL Filter Change Servicei Instructions Cooling System Tightening the FAN BeltBleeding the Fuel System Engine Adjustment Battery MaintenanceServicing Optional Spark Arrestor Welder / Generator Maintenance Gfci Module Testing and Resetting ProcedureTroubleshooting HOW to USE Troubleshooting GuideField Service Facility Contact your local AuthorizedWelding without a control cable High idle does not work Faulty control cable. Repair or Service Facility Your local Authorized FieldDiagrams DX450 RED-D-ARCDiagrams Diagrams Diagrams Diagrams Diagrams DX450 RED-D-ARC Wiring Diagram DX450 RED-D DimensionPrint ARCDX450 RED-D-ARC DX450 RED-D-ARC Precaucion Warnung