Lincoln Electric DX450 specifications Welder / Generator Maintenance

Page 31

D-6

MAINTENANCE

D-6

 

 

 

WELDER / GENERATOR

MAINTENANCE

STORAGE: Store in clean, dry protected areas.

CLEANING: Blow out the generator and controls peri- odically with low pressure air. Do this at least once a week in particularly dirty areas.

BRUSH REMOVAL AND REPLACEMENT: It’s nor- mal for the brushes and slip rings to wear and darken slightly. Inspect the brushes when a generator over- haul is necessary.

CAUTION

Do not attempt to polish slip rings while the engine is running.

WARNING

Service and Repair should only be performed by Factory Trained Personnel. Unauthorized repairs performed on this equipment may result in dan- ger to the technician and machine operator and will invalidate your factory warranty. For your safety and to avoid Electrical Shock, please observe all safety notes and precautions.

GFCI MODULE TESTING AND RESETTING PROCEDURE

The GFCI module should be properly tested at least once every month or whenever it is tripped. To properly test and reset the GFCI module:

If the module has tripped, first carefully remove any load and check it for damage.

If the equipment has been shut down, it must be restarted.

The equipment needs to be operating at high idle speed and any necessary adjustments made on the control panel so that the equipment is providing at least 80 volts to the receptacle input terminals.

The circuit breaker for this receptacle must not be tripped. Reset if necessary.

Push the "Reset" button located on the GFCI module. This will assure normal GFCI operation.

Plug a night-light (with an "ON/OFF" switch) or other product (such as a lamp) into the Duplex receptacle and turn the product "ON".

Push the "Test" button located on the GFCI module. The night-light or other product should go "OFF".

Push the "Reset" button, again. The light or other product should go "ON" again.

If the light or other product remains "ON" when the "Test" button is pushed, the GFCI module is not work- ing properly or has been incorrectly installed (miswired). If your GFCI module is not working properly, contact a qualified, certified electrician who can assess the situa- tion, rewire the GFCI module if necessary or replace the device.

DX450 (RED-D-ARC)

Image 31
Contents RED-D-ARC DX450 RED-D-ARC SafetyElectric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéCustomer Assistance Policy Thank YouTable of Contents Series Section DSection E Section FTechnical Specifications DX450 K2712-1 InstallationVRD Voltage Reduction Device Safety PrecautionsLocation and Ventilation OIL PRE-OPERATION Engine ServiceVehicle Mounting TowingEngine Cooling System Battery ConnectionRemote Control FuelElectrical Connections Standby Power Connections Auxiliary Power ReceptaclesDuplex Receptacles and Gfci Modules Xyz Connection of DX450 to Premises WiringAcross The-Arc Model Connection of Lincoln Electric Wire FeedersConnection of LN-7 or LN-8 to the DX450 Shut the welder off Connection of LN-15 to the DX450 Shut the welder offInstallation General Description OperationFigure B.1 Weld Mode Selector SwitchTable B.1 Wire Feeder Voltmeter SwitchTable B.2 Engine ControlsGlow Plug Push Button Starting the EngineDuty Cycle Stopping the EngineWelder Operation Constant Current CC-STICK WeldingTypical Current Ranges 1 for Tungsten ELECTRODES2 TIG WeldingTable B.3 Plus Wire WELDING-CVAuxiliary Power ARC GougingTIG Options AccessoriesField Installed Options / Accessories Wire Feeder OptionsRoutine Maintenance MaintenanceEngine OIL Change AIR CleanerOIL Filter Change Servicei Instructions Tightening the FAN Belt Cooling SystemBleeding the Fuel System Battery Maintenance Engine AdjustmentServicing Optional Spark Arrestor Gfci Module Testing and Resetting Procedure Welder / Generator MaintenanceHOW to USE Troubleshooting Guide TroubleshootingContact your local Authorized Field Service FacilityWelding without a control cable High idle does not work Faulty control cable. Repair or Your local Authorized Field Service FacilityDX450 RED-D-ARC DiagramsDiagrams Diagrams Diagrams Diagrams Diagrams DX450 RED-D-ARC Wiring Diagram ARC DimensionPrint DX450 RED-DDX450 RED-D-ARC DX450 RED-D-ARC Precaucion Warnung