Lincoln Electric IM647-A manual 3MAINTENANCED-3, For K575 models

Page 14

D-3MAINTENANCED-3

(4 CONTROL LEADS)

CABLE

CONTROL LEAD

Figure E.2

d)Remove gun tube connector from cable by unscrewing connector nut from gun tube connec- tor. If the cable inner tube is difficult to remove from the connector assembly, carefully slit it length- wise with a knife up to the brass connector.

e)Uncouple the strain relief by pushing its outer housing toward the middle of the cable. Move the strain relief and the cable boot toward the middle of the cable, past the damaged section.

f)For K575 models

Cut off damaged section of cable and strip off the outer jacket 2.15 inches back. Be careful not to cut the insulation on the control wires while stripping jacket. Pull control leads back and trim the exposed copper and inner tube back .50 inch. Strip all four control leads .125 inch back and crimp a new S8053-169 terminal to each lead. Apply heat shrink tubing or electrical tape to terminals to prevent electrical contact with other terminals. (See Figure E.2).

For K1723 models:

Cut off damaged section of cable and strip off the outer jacket 1.65 inches back. Be careful not to cut the insulation on the control wires while stripping jack- et. Strip all four control leads .25 inch back and crimp a new S19492-2 terminal to both the black lead and the white lead. Remove the leads connected to the red and blue control leads from the cutoff cable and solder these leads to the blue and red leads of the newly trimmed cable. Insulate connections with heat shrink tubing or tape. (See Figure E.3).

1/4" (6.4mm) SKIN (4 CONTROL LEADS)

CABLE

CONTROL LEADS

(41.9mm SKIN)

Figure E.3

MAGNUM® 400 FM DUAL PROCEDURE GUNS

Image 14
Contents Magnum 400 Dual Procedure IM647-A Safety California Proposition 65 WarningsElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion Précautions DE Sûreté Sûreté Pour Soudage a LʼArcThank You Magnum 400 FM Dual Procedure Guns Installation General DescriptionProduct Contact TIP and GAS Nozzle Installation Installation of the K489-7 and K573-1 FAST-MATE Adapter Kits Electrodes and Equipment Avoiding Wire Feeding Problems Operation Making a WeldMaintenance Figure E.1GUN Tubes and Nozzles GUN Cables3MAINTENANCED-3 For K575 modelsFigure E.4 For K575 Wire Feeder END Repair K575 Figure E.7 Thread Sizes for Magnum 400 Consumables Troubleshooting HOW to USE Troubleshooting GuideTroubleshooting Troubleshooting Magnum 400 FM Dual Procedure Guns Magnum 400 FM Dual Procedure Guns Magnum 400 FM Dual Procedure Guns Magnum 400 FM Dual Procedure Guns Precaucion Warnung