Lincoln Electric IM530-C manual Engine Problems

Page 30

TROUBLESHOOTING

Observe Safety Guidelines

detailed in the beginning of this manual.

Troubleshooting Guide

 

 

 

 

 

 

 

 

 

 

PROBLEMS

 

 

POSSIBLE AREAS OF

 

 

 

(SYMPTOMS)

 

 

MISADJUSTMENT(S)

 

 

 

 

 

 

 

ENGINE PROBLEMS

 

 

 

Engine will not idle down to low

 

 

1.

Idler Switch on HIGH Idle.

 

 

 

speed. (For Codes 10158, 10160

 

 

2.

Engine choke is not fully open.

 

 

 

only.)

 

 

3.

External load on welder or

 

 

 

 

 

 

 

auxiliary power. - Remove load.

 

 

 

 

 

 

4.

Machine output is under load or

 

 

 

 

 

 

 

idle switch in wrong position.

 

 

 

 

 

 

5.

Idle solenoid does not pull in.

 

 

 

Engine idles down to low idle but

 

 

1.

Engine low idle RPM may be set

 

 

 

will not stay at low idle. (For Codes

 

 

 

too low. - Contact Lincoln Field

 

 

 

10158, 10160 only.)

 

 

 

Service Facility.

 

 

 

 

 

 

 

 

 

 

 

Engine will not go to high idle when

 

 

1.

Check Work and Electrode

 

 

 

attempting to weld or use generator

 

 

 

cables for loose or faulty

 

 

 

power. (For Codes 10158, 10160

 

 

 

connections.

 

 

 

only.)

 

 

2.

Mechanical linkage from

 

 

 

 

 

 

 

solenoid to engine stuck.

 

 

 

 

 

 

3.

Open connection in weld circuit.

 

 

 

 

 

 

4.

No output from receptacles or

 

 

 

 

 

 

 

load too small.

 

 

 

 

 

 

5.

Idler pc board is not sensing

 

 

 

 

 

 

 

output current.

 

 

 

 

 

 

6.

Faulty idler pc board.

 

 

 

Engine will not go to high idle when

 

 

1.

Auxiliary load less than 100

 

 

 

using auxiliary power. (For Codes

 

 

 

watts.

 

 

 

10158, 10160 only.)

 

 

2.

Circuit breaker CB1 or CB2

 

 

 

 

 

 

 

tripped or faulty.

 

 

 

 

 

 

3.

Mechanical linkage from

 

 

 

 

 

 

 

solenoid to engine stuck.

 

 

 

 

 

 

 

 

 

 

 

Engine runs erratic or stops running

 

 

1.

Oil level may be low activating

 

 

 

or engine surges at low idle. (For

 

 

 

the engine “Oil Gard” shutdown

 

 

 

Codes 10158, 10160 only.)

 

 

 

system. - Check oil level.

 

 

 

 

 

 

2.

Idle solenoid linkage or engine

 

 

 

 

 

 

 

idle misadjusted.

 

 

 

 

 

 

 

 

 

 

 

Recoil starter is hard to pull.

 

 

1.

Crankcase may be over-filled

 

 

 

 

 

 

 

with oil. - Check oil level.

 

 

 

Engine will not start or starts but

 

 

1.

Water in engine from rain and / or

 

 

 

runs rough with low power.

 

 

 

condensation. - Remove spark plug and

 

 

 

 

 

 

 

dry it if wet. Blow low pressure compressed

 

 

 

 

 

 

 

air in spark plug port while pulling recoil

 

 

 

 

 

 

 

starter. Re-install spark plug.

 

 

 

 

 

 

2. Spark plug may be faulty.

 

 

 

 

 

 

3. Air filter element saturated with water and /

 

 

 

 

 

 

 

or oil - Replace.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RECOMMENDED COURSE OF ACTION

If all recommended possible areas of misadjustment have been checked and the problem persists,

Contact your local Lincoln Authorized Field Service Facility.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your local Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

WELDANPOWER 125

23

Image 30
Contents Weldanpower Safety California Proposition 65 WarningsElectric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcPlease Examine Carton and Equipment For Damage Immediately On-Line Product RegistrationTable of Contents Amps Location and Ventilation InstallationSafety Precautions StoringTilting PRE-OPERATION Engine ServiceStacking LiftingTotal Combined Length Electrode and Work Cables Electrical Output ConnectionsCable Size and Length Cable Amps Length 30% Duty CycleCable Installation Machine GroundingAuxiliary Power Receptacles Plugs and Hand Held EquipmentCircuit Breakers Table A.2 Electrical Device USE with the Weldanpower Type Common Electrical Devices Possible ConcernsWeldanpower Safety Instructions Operating InstructionsGeneral Warnings Operation Welding Capability LimitationsControls and Settings Figure B.1 and B.1a Output Panel ControlsEngine Operation Engine Control Function/OperationStarting/Shutdown Instructions Break-in Period To USE the Weldanpower 125 for WeldingWelding Operation Low Oil SensingAfter YOU Finish the Weld Auxiliary Power Operation To USE the Weldanpower 125 AS AN Auxiliary Power SupplyTable B.2 Electrode Selection Guide Table B.3 Auxiliary Power Applications Accessories OPTIONS/ACCESSORIESSafety Precautions Routine and Periodic Maintenance Engine Maintenance Parts Maintenance Engine Adjustments Slip RingsTroubleshooting How To Use Troubleshooting GuideTroubleshooting Guide Contact your local Lincoln Authorized Field Service FacilityEngine Problems Welding Problems Wiring Diagram 125Enhanced Diagram Diagram Dimensionprint Weldanpower Weldanpower Precaucion Warnung