Lincoln Electric IM856 manual Troubleshooting

Page 29

E-3

TROUBLESHOOTING

E-3

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

Engine will not go to high idle when

1.

No voltage signal from the

using auxiliary power.

 

current sensor.

 

 

2.

Auxiliary power load less than

 

 

 

100 to 150 watts.

 

 

3.

Faulty P.C. Board.

 

 

 

 

Engine will not crank or is hard to

1.

Battery will not hold a charge.

crank.

 

Faulty Battery.

 

 

2.

No or insufficient charging

 

 

 

current.

 

 

3.

Loose battery cable

 

 

 

connection(s).

 

 

 

 

Engine shuts down.

1.

Out of fuel.

 

 

2.

Low oil level.

 

 

Engine does not develop full power. 1. Fuel filter clogged.

 

 

2.

Air filter clogged.

 

 

 

Engine is hard to start.

1.

Spark plugs do not have

 

 

 

specified gap.

If all recommended possible areas of misadjustment have been checked and the problem persists, Contact your local Lincoln Authorized Field Service Facility.

2.Spark plugs are fouled.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

RANGER GXT

Image 29
Contents Ranger GXT California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding Sparks can cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéThank You Table of Contents Auxiliary Power InstallationHeight Width Depth Weight Welding OutputMachine Grounding Safety PrecautionsSpark Arrester TowingGasoline PRE-OPERATION ServiceBattery Connections Welding Output Cables Additional Safety PrecautionsTotal Combined Length of Electrode and Work Cables Angle of OperationInstructions Connection of Lincoln Electric Wire FeedersLocation / Ventilation Stacking120/240 Volt Dual Voltage Receptacle Auxiliary PowerDuplex Receptacles Motor StartingType Common Electrical Devices Possible Concerns Electrical Device USE with the Ranger GXTStandby Power Connections Auxiliary Power While WeldingSimultaneous Welding and Power Connection of Ranger GXT to Premises Wiring Operation Engine SwitchGeneral Description Welder Controls Function and OperationRanger GXT Approximate Fuel Consumption Polarity Switch PIN ConnectorLocal / Remote Control Switch BREAK-IN Period STARTING/SHUTDOWN InstructionsStarting the Engine Stopping the EngineWelding Process Wire Feed Welding Processes Constant VoltageStick Constant Current Welding TIG Constant Current WeldingStick Auto K857 25 ft.7.5m or K857-1100 ft.30.4m AccessoriesK1745-1 GAS Cylinder Holder Recommended Equipment Wire FeedStick TIGSafety Precautions MaintenanceRoutine Maintenance Engine OIL ChangeOIL Filter Change AIR Cleaner and Other MaintenanceEngine Adjustments HOW to USE Troubleshooting Guide TroubleshootingTroubleshooting Troubleshooting Diagrams PIN Connector M20512 Ranger GXT Precaucion Warnung