Lincoln Electric K471, K470, K514, K2286-1, K1802-1 manual Connection to Feeder

Page 15

B-4

INSTALLATION

B-4

 

 

 

CONNECTION TO FEEDER

CONNECTION TO LINCOLN FEEDERS

Gun cable assemblies which were assembled with a K466-1 or -8 Connection Kit will connect easily to any Lincoln LN-7, LN-8, LN-9, SP-200 or LN-25 feeder.

a.Check that the drive roll(s) and feeder guide tubes are appropriate for the electrode size being used.

b.Fully push the brass connector end of the gun cable into the conductor block on the outgoing side of the feeder wire drive. Secure the cable using the hand screw or set screw in the conductor block.

c.Insert the control cable plug from the feeder trigger circuit into the mating socket on the feeder end cable handle (See K466-1 Installation Section.)

d.Slide the free end of the flexible hose onto the barbed gas fitting on the front of the Lincoln feeder (See K466-1 or -8 Installation Section.) Move the corresponding tubing clamp down near the end of the tube to assure a good gas seal.

CONNECTION TO ADAPTED FEEDERS

Gun cable assemblies which were assembled with a K466-2 Connection Kit will connect easily to any prop- erly adapted feeder.

a.Check that the adapter and feeder outgoing guide, as well as the drive roll, are appropriate for the elec- trode size being used.

b.Fully push the brass connector end of the gun cable into the brass adapter on the outgoing side of the feeder wire drive. Secure the cable using the hand screw or set screw in the adapter.

c.Insert the control cable plug from the feeder trigger circuit into the mating socket on the gun cable con- nector handle .

CONNECTION TO MILLER FEEDERS

Gun and cable assemblies which were assembled with a K466-3 Connector Kit will connect easily to a variety of popular Miller wire feeders.

a.Check that the gun liner, connector cap liner, drive rolls and guide tubes are appropriate for the elec- trode size being used.

b.Fully push the brass connector end of the gun and cable into the connector receptacle on the outgoing side of the feeder wire drive. Tighten the hand screw to clamp down on the connector.

c.Insert the control cable plug from the feeder trigger circuit into the mating socket on the gun cable con- nector handle.

CONNECTION TO HOBART FEEDERS

Gun and cable assemblies which were assembled with a K466-4 Connector Kit will connect easily to a variety of Hobart wire feeders.

a.Check that the gun liner, connector cap liner, drive rolls and guide tubes are appropriate for the elec- trode size being used.

b.Fully push the brass connector end of the gun and cable into the connector receptacle on the outgoing side of the feeder wire drive. Tighten the hand screw to clamp down on the connector.

c.Insert the control cable plug from the feeder trigger circuit into the mating socket on the gun cable con- nector handle.

d.Slide the free end of the flexible hose (mounted to the gun in K466-4 Installation Section) onto the gas fitting on the Hobart wire feeder. Move the corre- sponding tubing clamp down near the end of the tube to assure a good gas seal.

CONNECTION TO L-TEC ADAPTED FEEDERS

Gun and cable assemblies which were assembled with a K466-5 connection kit will connect easily to an L-Tec feeder equipped with an L-Tec feeder connector assembly. L-Tec feeders require this connector assem- bly (similar to a Tweco adapter) to connect with a gun and cable.

a.Check that the adapter and feeder outgoing guide as well as the drive roll, are appropriate for the elec- trode size being used.

b.Fully push the brass connector end of the gun cable into the brass adapter on the outgoing side of the feeder wire drive. Secure the cable using the hand screw, set screw, or pin.

MAGNUM 300 & 400

Image 15
Contents Magnum 300 California Proposition 65 Warnings SafetyElectric Shock can kill Welding Sparks can cause fire or explosion Précautions DE Sûreté Thank You Table of Contents General Description General DescriptionMagnum 300 300 amperes AT 60% Duty Cycle with CO2 GAS Magnum 400 400 amperesAT 60% Duty Cycle with CO2 GAS 4GENERAL DESCRIPTIONA-4 Safety Precautions InstallationInstallation Contact TIP and GAS Nozzle Installation Connection to Feeder Connection to Lincoln 10 Series Feeders Electrodes and Equipment OperationGUN Tubes and Nozzles MaintenanceCable Wire Feeder END Repair Requires 2 S19492-1 Cable Handle Strain Relief Housing Incoming Connector Thread Sizes for Magnum 300 & 400 Consumables Problems TroubleshootingTroubleshooting Magnum 300 Magnum 300 Precaucion Aviso DE