Lincoln Electric K471, K470, K514, K2286-1, K1802-1 manual Wire Feeder END Repair Requires 2 S19492-1

Page 20

D-3

MAINTENANCE

D-3

h.Pull the cut-off lead terminals off the trigger assem- bly and connect the replacement control lead ter- minals.

j.Position the cable boot and strain relief on the cable so it fits in cable handle cavity and lock the strain relief in place by pushing the two halves together.

k.Assemble cable in left side of gun handle. Assemble trigger into the proper handle cavity. Assemble right side of gun handle and tighten the three screws that hold the handle together. Refer to Figure 4.

l.Install gun tube per Gun Tubes and Nozzles Section.

m.Install and trim liner per Liner Installation Section.

WIRE FEEDER END REPAIR (Requires 2 S19492-1

Terminals)

a. Remove the cable liner per Removal, Installation, and Trimming Instruction.

b. Remove the feeder end connector, molded gas plug (or barbed fitting), cable handle nut, plastic

tailpiece and connector cover (see Figure 5).

NOTE: In order to remove the cable handle nut, the tail of the connector cover must be depressed and the cable handle nut rotated 1/4 turn counterclock- wise as viewed from the feeder end.

c. Remove incoming connector from cable by unscrewing connector nut from incoming connec- tor. If the cable inner tube is difficult to remove from the connector assembly, carefully slit it lengthwise with a knife up to the brass connector.

d.Move the cable boot and cable handle toward the middle of the cable past the damaged section.

e.Cut off the damaged section of cable and strip off the outer jacket as shown in Figure 2. Be careful not to cut the insulation on the control wires while stripping jacket. Strip the red and white control leads 1/4 inch (6.4 mm) from the end and crimp a new S19492-1 terminal to each lead.

NOTE: The cable contains three control leads. Any two control leads can be used, provided the two colors used are the same at both ends. The extra lead is a spare that can be used if one of the other leads breaks.

Figure 4

MAGNUM 300 & 400

Image 20
Contents Magnum 300 Safety California Proposition 65 WarningsElectric Shock can kill Welding Sparks can cause fire or explosion Précautions DE Sûreté Thank You Table of Contents General Description General DescriptionMagnum 300 300 amperes AT 60% Duty Cycle with CO2 GAS Magnum 400 400 amperesAT 60% Duty Cycle with CO2 GAS 4GENERAL DESCRIPTIONA-4 Installation Safety PrecautionsInstallation Contact TIP and GAS Nozzle Installation Connection to Feeder Connection to Lincoln 10 Series Feeders Operation Electrodes and EquipmentMaintenance GUN Tubes and NozzlesCable Wire Feeder END Repair Requires 2 S19492-1 Cable Handle Strain Relief Housing Incoming Connector Thread Sizes for Magnum 300 & 400 Consumables Troubleshooting ProblemsTroubleshooting Magnum 300 Magnum 300 Precaucion Aviso DE