Lincoln Electric K2286-1, K471, K470, K514, K1802-1 manual Maintenance, GUN Tubes and Nozzles

Page 18

D-1

MAINTENANCE

D-1

REMOVAL, INSTALLATION AND TRIMMING INSTRUCTIONS FOR MAGNUM LINERS

NOTE: The variation in cable lengths prevents the interchangeability of liners. Once a liner has been cut for a particular gun, it should not be installed in anoth- er gun, unless it can meet the liner cut off length requirement. Liners are shipped with the jacket of the liner extended the proper amount.

a. Remove the gas nozzle and nozzle insulator. Loosen the set screw located in the side of the dif- fuser with 5/64 (2.0 mm) Allen wrench (provided with the gun or connector kit).

b.Remove the gas diffuser from gun.

c.Lay gun and cable out straight on a flat surface. For all K466 except K466-3 and K466-4 Connections:

Loosen set screw located in the brass cable con- nector at the wire feeder end of the cable using the same 5/64 (2.0 mm) Allen wrench. Pull liner out of cable. (REFER TO FIGURE 1 IN INSTALLATION FOR EACH)

<OR>

For K466-3 and K466-4 CONNECTIONS:

Remove the connector cap with the wrench provid- ed. Pull liner out of cable. If the liner is going to be replaced with a different size liner, loosen set screw on the connector cap and remove piece of liner material.

d. For installation and trimming instructions for Magnum liners see “LINER INSTALLATION” in INSTALLATION section.

GUN TUBES AND NOZZLES

a.Replace worn contact tips as required.

b.Remove spatter from inside of gas nozzle and from tip after each 10 minutes of arc time or as required.

c.To remove gun tube from gun, loosen socket-head clamping screw in handle with 3/16” (4.8 mm) Allen wrench. Remove gas nozzle and nozzle insulator and also loosen small set screw in the diffuser using 5/64” (2.0 mm) Allen wrench.

NOTE: Small set screw in the diffuser must be loosened, otherwise liner could be damaged when attempting to remove gun tube.

Pull gun tube out from gun handle. To reinstall, insert the gun tube, push in as far as possible and retighten screws.

GUN CABLES

CABLE CLEANING

Clean cable liner after using approximately 300 pounds (136 kg) of electrode. Remove the cable from the wire feeder and lay it out straight on the floor. Remove the contact tip from the gun. Using an air hose and only partial pressure, gently blow out the cable liner from the gas diffuser end.

CAUTION

Excessive pressure at the start may cause the dirt to form a plug.

------------------------------------------------------------------------

Flex the cable over its entire length and again blow out the cable. Repeat this procedure until no further dirt comes out.

CABLE REPAIR (ALL K470, K471 & K541

MODELS)

The Magnum 300 and Magnum 400 guns feature the use of repairable cable connectors. If the cable ever gets severely damaged. it may be cut shorter and repaired by the user. Repair cables as follows:

GUN TUBE END REPAIR (Requires 2 S19492-2 Terminals)

a. Remove the cable liner per Removal, Installation and Trimming Instructions.

b.Remove the gun tube per Gun Tubes and Nozzles Section.

c.Remove three #6 screws from the gun handle, sep- arate the two halves, and remove the cable from the handle along with the trigger assembly.

d.Remove gun tube connector from cable by unscrewing connector nut from gun tube connec- tor. If the cable inner tube is difficult to remove from the connector assembly, carefully slit it lengthwise with a knife up to the brass connector.

MAGNUM 300 & 400

Image 18
Contents Magnum 300 Safety California Proposition 65 WarningsElectric Shock can kill Welding Sparks can cause fire or explosion Précautions DE Sûreté Thank You Table of Contents General Description General DescriptionMagnum 300 300 amperes AT 60% Duty Cycle with CO2 GAS Magnum 400 400 amperesAT 60% Duty Cycle with CO2 GAS 4GENERAL DESCRIPTIONA-4 Installation Safety PrecautionsInstallation Contact TIP and GAS Nozzle Installation Connection to Feeder Connection to Lincoln 10 Series Feeders Operation Electrodes and EquipmentMaintenance GUN Tubes and NozzlesCable Wire Feeder END Repair Requires 2 S19492-1 Cable Handle Strain Relief Housing Incoming Connector Thread Sizes for Magnum 300 & 400 Consumables Troubleshooting ProblemsTroubleshooting Magnum 300 Magnum 300 Precaucion Aviso DE