Lincoln Electric K470, K471, K514, K2286-1, K1802-1 manual Connection to Lincoln 10 Series Feeders

Page 16

B-5

INSTALLATION

B-5

c.Insert the control cable plug from the feeder trigger circuit into the mating socket on the gun cable con- nector handle. For machines with a twist-lock trig- ger lead receptacle, if the L-Tec gun control cable does not easily connect with the socket, the gun control cable that came with the K466-5 kit can be used. To do this, cut off the gun control leads as close to the forked terminals as possible and skin back the leads 7/16” (11 mm). Remove the twist- lock plug from the L-Tec control cable and connect it to the K466-5 cable. Make sure the outer jacket of the connector is caught within the plug’s strain relief.

CONNECTION TO LINCOLN WIREMATIC, HOBART

SERIES 2000 FEEDERS, OR SP100T TYPE FEEDERS.

Gun cable asssemblies which were assembled with a K466-6, K466-7 or K466-9 Connection Kit will connect easily to a feeder.

a.Check that the adapter and feeder outgoing guide, as well as the drive roll, are appropriate for the elec- trode size being used.

b.Fully push the brass connector end of the gun cable into the outgoing side of the feeder wire drive. Secure the cable using the hand screw on the wire feeder.

c.Insert the control cable plug from the feeder trigger circuit into the mating socket on the gun cable con- nector handle.

CONNECTION TO LINCOLN 10 SERIES FEEDERS

Gun cable assemblies which were assembled with a K466-10 Connection Kit or K471-21 thru -23 gun and cable assemblies will connect easily to a 10 Series feeder.

a.Check that the K1500-2 gun adapter is in place on the wire feeder. Check that the feeder guide tubes, as well as the drive roll(s), are appropriate for the electrode size being used.

b.Fully push the brass connector end of the gun cable into the gun adapter on the outgoing side of the feeder wire drive and secure the cable using the hand screw.

c.Insert the control cable plug from the feeder trigger circuit into the mating socket on the gun cable con- nector handle.

MAGNUM 300 & 400

Image 16
Contents Magnum 300 Safety California Proposition 65 WarningsElectric Shock can kill Welding Sparks can cause fire or explosion Précautions DE Sûreté Thank You Table of Contents General Description General DescriptionMagnum 300 300 amperes AT 60% Duty Cycle with CO2 GAS Magnum 400 400 amperesAT 60% Duty Cycle with CO2 GAS 4GENERAL DESCRIPTIONA-4 Installation Safety PrecautionsInstallation Contact TIP and GAS Nozzle Installation Connection to Feeder Connection to Lincoln 10 Series Feeders Operation Electrodes and EquipmentMaintenance GUN Tubes and NozzlesCable Wire Feeder END Repair Requires 2 S19492-1 Cable Handle Strain Relief Housing Incoming Connector Thread Sizes for Magnum 300 & 400 Consumables Troubleshooting ProblemsTroubleshooting Magnum 300 Magnum 300 Precaucion Aviso DE