Lincoln Electric IM972 manual Installation, Technical Specifications Outback 185 K2706-1

Page 8

A-1

 

 

 

INSTALLATION

 

 

 

A-1

TECHNICAL SPECIFICATIONS - OUTBACK™ 185 (K2706-1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT - GASOLINE ENGINE

 

 

 

 

 

 

 

 

 

 

 

 

 

Make/Model

 

Description

 

Speed (RPM)

 

Displacement

Ignition

 

Capacities

 

 

 

 

 

 

 

 

 

 

 

 

 

System

 

 

 

 

 

 

 

 

 

 

 

KOHLER

 

1 cylinder

3750RPM High Idle

 

21.96 cu. in

Electric & Recoil

 

Fuel: 6.86 gal.

CS 12.75

 

4 cycle

1825RPM Low Idle

 

(360 cc)

Start;

 

(24.9L)

 

 

air-cooled

3400RPM Full Load

 

 

 

 

 

 

 

 

 

Bore x Stroke

 

 

 

 

 

 

OHV gasoline

 

 

 

 

Manual

 

Oil: 1.2 Qts.

 

 

12.75 HP @

 

 

 

 

 

Choke

 

(1.1L)

 

 

3600 RPM

 

 

 

 

3.35” x 2.48”

 

 

 

 

 

 

Aluminum Block

 

 

 

 

(85 mm x 63mm)

 

 

 

 

 

 

w/ Cast Iron Sleeve

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATED OUTPUT - WELDER

 

 

 

 

AMPS @ DC CONSTANT CURRENT

 

DUTY CYCLE

VOLTS @ RATED AMPERES

100

 

 

 

100%

 

 

25

130

 

 

 

60%

 

 

25

150

 

 

 

20%

 

 

25

185

 

 

 

MAX OUTPUT

 

 

---

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT -WELDER AND GENERATOR

 

 

Welding Ranges

 

Welding Open Circuit Voltage

AC Auxiliary Power

 

 

 

 

 

 

 

 

 

4600 Watts 115V 1PH

 

 

 

 

 

 

 

 

 

 

100% Duty Cycle

50 - 185 Amps DC

 

80 VDC Max.

5700 Peak Watts

 

 

 

 

 

 

 

 

 

5200 Continuous Watts

 

 

 

 

 

 

 

 

 

120 / 230 V 1PH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PHYSICAL DIMENSIONS

 

 

 

 

HEIGHT

 

WIDTH

 

 

DEPTH

 

 

WEIGHT

25.47 in.

 

21.12 in.

 

 

31.48 in.

 

 

310.0 lbs.

646.94 mm

 

536.45 mm

 

 

799.59 mm

 

 

 

140.6 kg

 

 

 

 

 

 

 

 

 

 

OPERATING TEMPERATURE RANGE

 

 

STORAGE TEMPERATURE RANGE

 

 

 

 

 

 

 

 

 

 

0° F TO 104° F (-18° C TO 40° C)

 

-40° F TO 131° F (-40° C TO 55° C)

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTBACK™ 185

®

Image 8
Contents Safety Depends on You OutbackSafety California Proposition 65 WarningsElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a LʼArcThank You Table of Contents Installation Technical Specifications Outback 185 K2706-1Height Width Depth Weight Amps @ DC Constant Current Duty Cycle Volts @ Rated AmperesStoring Safety PrecautionsLocation and Ventilation PRE-OPERATION Engine Service StackingTilting OILOutback 185 Output Connections Welding Cable ConnectionsTable A.1 Recommended Welding Cable Size and Length Total Combined Length Electrode and Work CablesCable Installation Machine GroundingAuxiliary Power Receptacles Premises WiringPlugs and Hand Held Equipment Circuit BreakersTable A.2 Electrical Device USE with the Outback Type Common Electrical Devices Possible ConcernsSafety Instructions OperationEngine Start Welding Capability LimitationsAuxiliary Power WELDER/GENERATOR ControlsOutput Panel Controls WeldingKohler CS 12.75 HP Engine OperationStopping the Engine Welding Operation To USE the Outback 185 for WeldingAfter YOU Finish the Weld Plasma Cutting with Lincoln Pro-CutAuxiliary Power Operation To USE the Outback 185 AS AN Auxiliary Power SupplyGeneral Information Table B.2 Electrode Selection GuideTable B.3 Auxiliary Power Applications Accessories OPTIONS/ACCESSORIESMaintenance Safety PrecautionsMaintenance Engine MaintenanceSpark Plug Service Engine AdjustmentsEngine Maintenance Parts Slip RingsTroubleshooting HOW to USE Troubleshooting GuideProblems SymptomsCourse of Action Contact your local LincolnProblems Possible Symptoms Cause Recommended Course of ActionWelding Problems Diagrams Printdimension 185Outback Precaucion Warnung