Lincoln Electric K126-10, K126-12, K126-11 manual Connection to Feeder with Ready to Weld GUN

Page 11

A-4

INSTALLATION

A-4

 

 

 

Read this entire installation section before you start installation.

SAFETY PRECAUTIONS

WARNING

ELECTRIC SHOCK can kill.

• Do not touch electrically live parts such as output terminals or inter- nal wiring.

Insulate yourself from the work and ground.

Always wear dry insulating gloves.

------------------------------------------------------------------------

CONNECTION TO FEEDER WITH READY TO WELD GUN

Connecting a K126-10 or K126-11 to a Lincoln Feeder (5/64” or smaller diameter wire)

The K126-10 or K126-11will connect to any wire feeder with a Lincoln style gun receiver bushing (i.e. LN-8, LN-9, LN-25 or any feeder with a K1500-1 bushing installed). (See Figure A.1)

1.Check that the drive roll(s) and feeder guide tubes are appropriate for the electrode size being used.

2.Fully push the brass connector end of the gun cable into the conductor block on the outgoing side of the feeder wire drive. Secure the cable using the hand screw or set screw in the con- ductor block.

3.Insert the round connector of the control cable into the mating connector on the front of the wire feeder.

FIGURE A.1

Connection to Adapted Feeders, Lincoln DH-10, LN-10, STT-10, and Power Feed 10 wire feeders (5/64” or smaller diameter wire).

The K126-12gun and cable assembly will connect easily to any properly adapted feeder.

1.Check that the adapter and feeder outgoing guide, as well as the drive roll, are appropriate for the electrode size being used. On Lincoln feeders, check that the K1500-2 gun adapter is in place.

2.Fully push the brass connector end of the gun cable into the brass adapter on the outgoing side of the feeder wire drive. Secure the cable using the hand screw or set screw in the adapter.

3.Insert the round connector of the control cable into the mating connector on the front of the wire feeder.

CONVERSION OF K126-10, K126-11 OR K126-12 TO WELD WITH OTHER WIRE FEEDERS

Prepare gun and determine correct connector kit

1.Determine which K466 or K613 kit is required for your system using (Tables A.1 and A.2) in the front part of the Installation Section.

2.Remove the insulator, tip holder and gun control cable.

3.Lay gun and cable out straight on a flat surface.

4.Loosen set screw located in the brass cable con- nector at the wire feeder end of the cable using the 5/64 (2.0 mm) Allen wrench. Pull liner out of cable.

5.Remove the brass cable connector from the feeder end of the gun using the wrench provided.

6.Install the new connector kit using the appropri- ate procedure which follows.

K466-3/K613-3 Installation (For Miller feeders)

1.Remove brass cable connector (see Figure A.2) from the kit and screw it on to the feeder end of the gun cable. Tighten the connection with the wrench provided.

2.Attach the round connector of the gun control cable provided to the trigger connector on the front of the Miller feeder.

K126-10, K126-11 AND K126-12 INNERSHIELD® PRO

Image 11
Contents K126-10, K126-11 and K126-12 Innershield Pro Gun Safety Depends on YouCalifornia Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionPrécautions DE Sûreté Thank You Section D Section aSection b Section CK126-10, K126-11 and K126-12 Innershield PRO InstallationDuty Cycle Amperes Model Cable LengthProduct TAbLE A.1Recommended Processes and Equipment General DescriptionConnection to Feeder with Ready to Weld GUN K466-3/K613-3 Installation For Miller feedersK613-6 Installation Lincoln Feeders, 3/32 diam- eter wire K466-4 Installation For Hobart feeders i.eK613-2, K613-7 Installation Tweco #5 compatible feeders Connection to L-Tec Adapted Feeders Connect Guns to Wire FeederConnection to Miller Feeders Connection to Hobart FeedersConnection to a Tweco #5 adapted feeder Connection to a Lincoln feeder for 3/32 diameter wireElectrodes and Equipment OperationManufacturer Model Diameter Or smaller wire AccessoriesWire Feeder Connection Kits Stainless Steel Jacketed Liner ASSEMbLY Wire Diameter Liner KP NoKP Numbers Wire Diameter Piece pack GUN TUbESFigure D.1 MaintenanceTROUbLESHOOTING Cause Recommended Course of Action SymptomsTROUbLESHOOTING Precaucion Warnung K126-10, K126-11 and K126-12 Innershield PRO K126-10, K126-11 and K126-12 Innershield PRO K126-10, K126-11 and K126-12 Innershield PRO