Lincoln Electric K126-12, K126-11, K126-10 manual K466-4 Installation For Hobart feeders i.e

Page 12

A-5

INSTALLATION

A-5

 

 

 

K466-4 Installation (For Hobart feeders; i.e. 27...)

1.Remove brass cable connector (see Figure A.2) from the K466-4 kit and screw it on to the feeder end of the gun cable. Tighten the connector with the wrench provided.

2.Attach the phone plug connector of the gun con- trol cable provided to the trigger connector on the front of the Hobart feeder.

K466-5 Installation (For L-Tec feeders equipped with an L-Tec feeder connector assembly, MIG 35, MIG 31A, 225...)

1.Remove brass cable connector (see Figure A.2) from the K466-5 kit and screw it onto the feeder end of the gun cable. Tighten the connection with the wrench provided.

2.For L-Tec machines that require trigger lead connections to be made at a terminal strip locat- ed within the machine (L-Tec 225), a gun con- trol cable with forked terminals is provided. Connect the terminated leads to the terminal strip. For a machine that requires a twist-lock gun control cable connection, continue to use the L-Tec gun control cable provided with the L- Tec wire feeder connector assembly. Connect the twist-lock plug to the proper receptacle on the machine.

K466-6, K466-7, and K466-9 Installation

(Wirematic, Hobart Series 2000 Feeders, SP100T

Type and Power MIG)

1.Remove brass cable connector (see Figure A.2) from the connector kit and screw it onto the feeder end of the gun cable. Tighten the connection with the wrench provided.

2.Attach the gun control cable provided to the trigger connector on the wire feeder.

K613-2, K613-7 Installation (Tweco #5 compatible feeders)

1.Remove brass cable connector from the kit and screw it onto the feeder end of the gun cable. Tighten the connection with the wrench provid- ed.

2.For K613-7, attach the round connector of the gun control cable provided to the trigger con- nector on the front of the Lincoln feeder.

K613-6 Installation (Lincoln Feeders, 3/32” diam- eter wire)

1.Remove brass cable connector and insulation tube from the kit. Slide the insulation tube onto the connector from the threaded end and screw it onto the feeder end of the gun cable. Tighten the connection with the wrench provided.

 

 

FIGURE A.2

 

 

INSULATION TUBE

 

 

 

 

(K466-1 ONLY)

 

GUN HANDLE

 

BRASS CABLE

 

 

SHIELD CLAMPING SCREWS

FEEDER END

 

 

CONNECTOR

 

 

 

CABLE HANDLE

 

 

 

 

 

 

 

 

 

GUN TUBE

 

MOLDED GAS

CABLE

 

 

 

PLUG

 

 

 

SET SCREW

 

 

TIP

 

 

 

 

LINER ASSEMBLY (LINER BUSHING TO BE SEATED

TIP HOLDER

TIGHT AGAINST BRASS CABLE CONNECTOR

 

 

INSULATOR

K126-10, K126-11 AND K126-12 INNERSHIELD® PRO

Image 12
Contents Safety Depends on You K126-10, K126-11 and K126-12 Innershield Pro GunSafety California Proposition 65 WarningsElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Thank You Section a Section bSection C Section DInstallation Duty Cycle AmperesModel Cable Length K126-10, K126-11 and K126-12 Innershield PROTAbLE A.1 ProductGeneral Description Recommended Processes and EquipmentK466-3/K613-3 Installation For Miller feeders Connection to Feeder with Ready to Weld GUNK466-4 Installation For Hobart feeders i.e K613-2, K613-7 Installation Tweco #5 compatible feedersK613-6 Installation Lincoln Feeders, 3/32 diam- eter wire Connect Guns to Wire Feeder Connection to Miller FeedersConnection to Hobart Feeders Connection to L-Tec Adapted FeedersConnection to a Lincoln feeder for 3/32 diameter wire Connection to a Tweco #5 adapted feederOperation Electrodes and EquipmentAccessories Wire Feeder Connection KitsManufacturer Model Diameter Or smaller wire Liner ASSEMbLY Wire Diameter Liner KP No KP Numbers Wire Diameter Piece packGUN TUbES Stainless Steel JacketedMaintenance Figure D.1TROUbLESHOOTING Symptoms Cause Recommended Course of ActionTROUbLESHOOTING Precaucion Warnung K126-10, K126-11 and K126-12 Innershield PRO K126-10, K126-11 and K126-12 Innershield PRO K126-10, K126-11 and K126-12 Innershield PRO