Lincoln Electric K126-12, K126-11, K126-10 manual Maintenance, Figure D.1

Page 18

D-1

MAINTENANCE

D-1

 

 

 

REMOVAL, INSTALLATION AND TRIMMING INSTRUCTIONS FOR  MAGNUM® LINERS

NOTE: The variation in cable lengths prevents the inter- changeability of liners. Once a liner has been cut for a par- ticular gun, it should not be installed in another gun, unless it can meet the liner cut off length requirement. Liners are shipped with the jacket of the liner extended the proper amount.

1.Remove the insulator and tip holder.

2.Lay the gun and cable straight on a flat surface.

For all connectors except K466-3, K466-4 and K613-3:

Loosen set screw located in the brass cable connector at the wire feeder end of the cable using the same 5/64 (2.0

mm)Allen wrench. Pull liner out of cable.

<OR>

For K466-3, K466-4 and K613-3 connectors:

Remove the connector cap with the wrench provided. Pull liner out of cable. If the liner is going to be replaced with a different size liner, loosen set screw on the con- nector cap and remove piece of liner material.

3.Insert a new untrimmed liner into the connector end of the cable. Be sure the liner bushing is stenciled appropriately for the wire size being used.

4.Be sure to fully seat the liner bushing in the connector and:

For all connector kits except K466-3, K466-4 and K613- 3, tighten the set screw in the cable connector.

<OR>

For K466-3, K466-4 and K613-3, screw in the connector cap provided in the kit until it seats on the face of the bushing. Then insert the appropriate piece of liner mate- rial into the connector cap and tighten the set screw. Three pieces of liner material are included in these con- nector kits to help guide the electrode through the con- nector cap. The piece with the smallest inner diameter is designed for .045" (1.2 mm) maximum diameter elec- trode and the other liners fit the following wires (maxi- mum size) in order of increasing inside diameter: 1/16” (1.6 mm), 5/64” (2.0 mm), 3/32” (2.4 mm) and 1/8” (3.2 mm).

NOTE: The maximum wire size for a K466-3 and K466-4 is 5/64”. Therefore the 3/32” and 1/8” liners are not included with these kits.

CAUTION

This screw should only be gently tightened. Overtightening will split or collapse the liner and cause poor wire feeding.

-------------------------------------------------------------------------------

5.Be sure the cable is straight and then trim the liner flush with the end of the gun tube.

6.Remove the gun tube and trim an additional 9/16” (12.7 mm) of material from the end of the liner (a 9/16” gage is included on the wrench supplied with the gun).

7.Replace the gun tube and tighten the clamping screw to secure it.

8.Reassemble the tip holder, insulator, and contact tip onto the end of the gun tube.

GUN TUbES AND NOzzLES

1.Replace worn contact tips as required.

2.Remove spatter from from contact tip, tip holder, insu- lator and gun tube after each 10 minutes of arc time or as required.

3.To remove gun tube from gun, loosen socket-head clamping screw in handle with 3/16" (4.8 mm) Allen wrench.

4.Pull gun tube out from gun handle. To reinstall, insert the gun tube, push in as far as possible, and retighten clamping screw.

CAbLE CLEANING

Clean cable liner after using approximately 150 (68 kg) pounds of electrode. Remove the cable from the wire feed- er and lay it out straight on the floor. Remove the contact tip from the gun. Using an air hose and only partial pressure, gently blow out the cable liner from the tip holder end.

CAUTION

Excessive pressure at the start may cause the dirt to form a plug.

-------------------------------------------------------------------------------

Flex the cable over its entire length and again blow out the cable. Repeat this procedure until no further dirt comes out.

Figure D.1

 

FEEDER END

GUN HANDLE

 

CABLE HANDLE

BRASS CABLE

 

 

 

CONNECTOR

 

 

Liner

LINER TRIM LENGTH 9/16" (14.3 mm)

SET SCREW

CABLE

 

LINER ASSEMBLY (LINER BUSHING TO BE SEATED

TIP HOLDER

TIGHT AGAINST BRASS CABLE CONNECTOR

TIP

 

 

INSULATOR

K126-10, K126-11 AND K126-12 INNERSHIELD® PRO

Image 18
Contents Safety Depends on You K126-10, K126-11 and K126-12 Innershield Pro GunSafety California Proposition 65 WarningsElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Thank You Section C Section aSection b Section DModel Cable Length InstallationDuty Cycle Amperes K126-10, K126-11 and K126-12 Innershield PROTAbLE A.1 ProductGeneral Description Recommended Processes and EquipmentK466-3/K613-3 Installation For Miller feeders Connection to Feeder with Ready to Weld GUNK466-4 Installation For Hobart feeders i.e K613-2, K613-7 Installation Tweco #5 compatible feedersK613-6 Installation Lincoln Feeders, 3/32 diam- eter wire Connection to Hobart Feeders Connect Guns to Wire FeederConnection to Miller Feeders Connection to L-Tec Adapted FeedersConnection to a Lincoln feeder for 3/32 diameter wire Connection to a Tweco #5 adapted feederOperation Electrodes and EquipmentAccessories Wire Feeder Connection KitsManufacturer Model Diameter Or smaller wire GUN TUbES Liner ASSEMbLY Wire Diameter Liner KP NoKP Numbers Wire Diameter Piece pack Stainless Steel JacketedMaintenance Figure D.1TROUbLESHOOTING Symptoms Cause Recommended Course of ActionTROUbLESHOOTING Precaucion Warnung K126-10, K126-11 and K126-12 Innershield PRO K126-10, K126-11 and K126-12 Innershield PRO K126-10, K126-11 and K126-12 Innershield PRO