INSTALLATION

A-4

 

 

 

ENGINE BREAK-IN

Lincoln Electric selects high quality, heavy-duty indus- trial engines for the portable welding machines we offer. While it is normal to see a small amount of crankcase oil consumption during initial operation, excessive oil use, wetstacking (oil or tar like sub- stance at the exhaust port), or excessive smoke is not normal.

Larger machines with a capacity of 350 amperes and higher, which are operated at low or no-load condi- tions for extended periods of time are especially sus- ceptible to the conditions described above. To accomplish successful engine break-in, most diesel- powered equipment needs only to be run at a reason- ably heavy load within the rating of the welder for some period of time during the engineʼs early life. However, if the welder is subjected to extensive light loading, occasional moderate to heavy loading of the engine may sometimes be necessary. Caution must be observed in correctly loading a diesel/generator unit.

1.Connect the welder output studs to a suit- able resistive load bank. Note that any attempt to short the output studs by con- necting the welding leads together, direct shorting of the output studs, or connecting the output leads to a length of steel will result in catastrophic damage to the gener- ator and voids the warranty.

2.Set the welder controls for an output cur- rent and voltage within the welder rating and duty cycle. Note that any attempt to exceed the welder rating or duty cycle for any period of time will result in catastrophic damage to the generator and voids the warranty.

3.Periodically shut off the engine and check the crankcase oil level.

ENGINE COOLING SYSTEM

The cooling system has been filled at the factory with

a50-50 mixture of ethylene glycol antifreeze and water. Check the radiator level and add a 50-50 solu- tion as needed. (See Engine Manual or antifreeze container for alternate antifreeze recommendation.)

BATTERY CONNECTION

WARNING: Use caution as the electrolyte is a strong acid that can burn skin and damage eyes.

Remove and discard the insulating caps from the neg- ative battery terminals. Attach and tighten negative battery cable terminals.

NOTE: This machine is furnished with wet charged batteries; if unused for several months, the batteries may require a booster charge. Be careful to charge the batteries with the correct polarity. Make sure that the batteries are level while charging.

WARNING

GASES FROM BATTERY can explode.

Keep sparks, flame and cigarettes away from battery.

To prevent EXPLOSION when:

INSTALLING A NEW BATTERY — disconnect

negative cable from old battery first and con- nect to new battery last.

CONNECTING A BATTERY CHARGER — remove battery from welder by disconnecting negative cable first, then positive cable and battery clamp. When reinstalling, connect negative cable last. Keep well ventilated.

USING A BOOSTER — connect positive lead to battery first then connect negative lead to neg- ative battery lead at the lower control panel support.

BATTERY ACID can burn eyes and skin.

Wear gloves and eye protection

and be careful when working near battery.

Follow instructions printed on battery.

IMPORTANT: To prevent ELECTRICAL DAMAGE WHEN:

a)Installing new batteries.

b)Using a booster.

Use correct polarity — Negative Ground.

To prevent BATTERY BUCKLING, tighten nuts on batteries only until snug. DO NOT OVERTIGHTEN.

SAE-400 SEVERE DUTY

Image 11
Contents IM870-A California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionSûreté Pour Soudage a LʼArc Précautions DE SûretéThank You Table of Contents Height Width Depth Weight Installation Technical Specifications SAE-400 Severe Duty Angle of Operation Safety PrecautionsLOCATION/VENTILATION StackingPRE-OPERATION Engine Service Engine Cooling System Battery ConnectionEngine BREAK-IN Table A.1 Combined Length of Electrode Work Cables Spark ArrestorWelding Output Cables Machine GroundingGeneral Description Safety InstructionsOperation Operating InstructionsDuty Cycle Design Features and AdvantagesFor Auxiliary Power Other FeaturesEngine Controls Welder Controls Remote ControlAuxiliary Power Controls Polarity SwitchCold Weather Starting Engine OperationStarting Instructions Stopping the EngineTypical Fuel Consumption K1690-1 Gfci Receptacle KIT AccessoriesOptional Field Installed Accessories OrderEngine OIL Change MaintenanceRoutine Maintenance Periodic MaintenanceCooling System Bearing MaintenanceCommutator and Brush Maintenance Fuel PRE-FILTER/WATER Separator AssemblySecondary Fuel Filter Engine Maintenance Components Make Part NumberWater Separator Element Gfci Receptacle Testing and RESET- Ting Procedure HOW to USE Troubleshooting Guide TroubleshootingContact your local Lincoln SymptomsContact your local Lincoln Authorized Field Service Facility Faulty receptacles Wiring Diagrams Wiring Diagrams M8869-36 Dimension PrintSAE-400 Severe Duty Precaucion Warnung