INSTALLATION

A-4

Work Cable Installation

Refer to Figure A.2.

1.Open the wire feed section door on the right side of the SP 170-I.

2.Pass the end of the work cable that has the termi- nal lug with the smaller hole through the Work Cable Access Hole (1) in the case front.

3.Route the cable under the feedplate (6) and in front of the Wire Feed Motor.

4.For Innershield Only: Refer to Figure A.2. As delivered, the machine is connected for negative electrode polarity. This is the appropriate configu- ration for the Innershield process. To complete installation, use the provided wing nut to connect the work cable’s terminal lug to the positive (+) out- put terminal (4) located above the Wire Feed Gearbox (5). Make sure that both wing nuts are tight.

5.For GMAW Only: Refer to Figure A.4. To wire for positive polarity (required for the GMAW process), connect the short cable attached to the connector block (1) to the positive (+) output terminal (4) and the work cable (3) to the negative (-) terminal (2).

Connecting Gun Cable to the SP 170-I

As shipped the gun is fitted with a liner suitable for all wire diameters from .025” - .035” (0.6mm - .9mm) and has an .035” (0.9mm) contact tip installed.

1.Refer to Figures A.2 and A.4. Unplug the machine or turn power switch to the OFF “O” position.

2.Pass the insulated terminals of the gun trigger con- trol leads, one at a time, through the Gun Cable and Control Lead Access Slot (A.2-2) in the case front. The leads are to be routed up the inside of the case front, behind the gas line.

3.Insert the connector on the gun conductor cable through the Gun Cable Access Hole (A.2-2) in the SP 170-I case front. Make sure the connector is all the way in the brass connector block to obtain proper gas flow. If the gun connector will not fully insert, unscrew the thumbscrew on the connector block a few turns. Rotate the connector so control leads are on the underside and tighten the Thumbscrew on the connector block.

4.Connect the gun trigger control lead terminals to the two insulated 1/4" (6,4 mm) tab terminal con- nector bushings located above the “Gun Trigger Connection” decal in the wire feed section (A.4). Either lead can go to either connector.

4

3

2

1

5

FIGURE A.4

GUN INSTALLATION

As shipped from the factory, the SP 170-I gun is ready to feed .035 Innershield. If other wire is to be used, change the contact tip to the appropriate size.

CAUTION

If the gun trigger switch being used is other than that supplied, the switch must be a normally open, momentary switch. The terminals of the switch must be insulated from the welding circuit. Malfunction of the SP 170-I may result if this switch shorts to the SP 170-I welding output cir- cuit or is common to any electrical circuit other than the SP 170-I trigger circuit.

GAS CONNECTION

When using the MIG process, a cylinder of shielding gas must be obtained. See Table B.1. Additionally a flow regulator is required. For more information, refer to the ACCESSORIES section.

SP 170-I

Image 13
Contents IM795 California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding Sparks can cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéSafety Safety Please Examine Carton and Equipment For Damage Immediately ViiOn-Line Product Registration Table of Contents Installation Identify and Locate Components Safety PrecautionsElectric Shock can kill Limitations Select Suitable LocationOutput Connections StackingWork Cable Installation GUN InstallationConnecting Gun Cable to the SP GAS ConnectionInput Connections Power Input Cable230 50/60 Line Cord ConnectionOperational Features and Controls Design Features AdvantagesOperation General DescriptionSwitch while welding Controls and SettingsWelding Capability Friction Brake Adjustment Wire LoadingWelding Operations Sequence of OperationFigure B.4 Process Guidelines Cleaning Tip And NozzleMaking a Weld Welding with Gmaw MIG Changing Machine Over to Feed Other Wire SizesOverload Protection Output Polarity Application ChartDrive Roll Orientation Optional Accessories AccessoriesK464 .035 0.9 mm Innershield Welding Kit K491 .045 1.2 mm Innershield Welding KitComplete Gun and Cable Assembly Code Replacement PartsMIG Gmaw Conversion Maintenance Safety Precautions MaintenanceRoutine Maintenance Configuration of Components in Wire Feeding System GUN and Cable MaintenanceGun Cable Cleaning Contact Tip Cable Liner Drive RollChanging Drive Roll Component Replacement ProceduresFigure D.2a Liner trim length for gun Lincoln Electric Changing LinerGUN Handle Parts Magnum 100L GUN Handle Parts Lincoln ElectricHOW to USE Troubleshooting Guide TroubleshootingRecommended Course of Action Problems Possible Areas Symptoms MisadjustmentsGAS Flow Problems Welding Problems Wiring Diagrams Page Page Precaucion Warnung