Lincoln Electric IM708 manual Installation, Technical Specifications Invertec V350-PRO CE

Page 10

 

A-1

 

 

 

 

 

INSTALLATION

 

 

A-1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TECHNICAL SPECIFICATIONS - INVERTEC V350-PRO (CE)

 

 

 

 

 

 

 

 

 

 

 

INPUT AC VOLTAGE & DC OUTPUT

 

 

 

 

 

Product

Ordering

Input AC

Rated DC Output

Output

 

Weight

Dimensions

 

 

 

Name

Information

Voltage

Amps/Volts/Duty Cycle

Range

 

with Cord

HxWxD

 

 

 

 

 

 

 

 

50/60 Hz

(continuous)

 

 

 

 

 

 

 

 

 

 

 

 

350A / 34V / 60%

 

 

 

14.7”x12.5”x

 

 

 

Invertec

 

 

200-220/

3

Phase

 

 

 

27.8”*

 

 

 

V350-

K1728-3

380-400/

320A

/ 33V / 60%

AMPS

 

82.5lbs

(373x318x

 

 

 

PRO

“CE”

415-440/

1

Phase

5-425

 

(37.4 kg)

706*)mm

 

 

 

60/50 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

275A / 31V /100%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 & 3 Phase

 

 

 

* Includes

 

 

 

 

 

 

 

 

 

 

 

 

 

handles

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* Overall Length Including Handle, 27.8” (706mm) without handle.

V350-PRO (CE) INPUT CURRENT (CE)

Recommended Fuse Sizes Based On The U.S. National Electrical Code And Maximum Machine Outputs

Input 50/60 Hz

Output

 

Recommended

 

 

Voltage

Phases

275Amps@

 

350Amps@

Line Cord

Size Fuse Size

Notes

 

 

31Volts(100%)

 

34Volts(60%)

AWG[IEC] SIZES

 

 

 

200

3

35

 

48

6

80A

Note 2

 

220

3

35

 

48

6

80A

Note 2

380

3

21

 

28

8

50A

 

 

400

3

20

 

27

8

50A

 

 

415

3

19

 

26

8

50A

 

 

440

3

18

 

24

8

50A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage

Phases

275Amps@

 

320Amps@

Line Cord

Size Fuse Size

Notes

 

 

31Volts(100%)

 

33Volts(60%)

 

 

 

 

200

1

----

 

----

---

-----

Note 1

220

1

64

 

82

4

125A

Note 2

380

1

44

 

55

6

80A

Note 2

400

1

40

 

50

8

80A

 

 

415

1

38

 

48

8

80A

 

 

440

1

35

 

45

8

80A

 

 

 

 

 

 

 

 

 

 

 

1.Not rated is indicated by 4-x's in the box on the rating plate

2.When operating on these inputs, the line cord should be changed to an input conductor of 6 AWG or larger.

OUTPUT CABLES, CONNECTIONS AND LIMITATIONS

Select the output cable size based upon the following chart.

Cable sizes for Combined Length of Electrode and Work Cable (Copper) 75C rated:

 

DUTY CYCLE

CURRENT

LENGTH UP 61m (200 FT)

61-76m (200-250 FT)

 

 

100%

275

1/0

1/0

 

 

60%

350

1/0

2/0

 

 

 

 

 

 

 

V350-PRO (CE)

Image 10
Contents Invertec V350-PRO CE IECSafety California Proposition 65 WarningsElectric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté V350-PRO CE Electromagnetic Compatibility EMCSafety Vii Please Examine Carton and Equipment For Damage ImmediatelyTable of Contents Installation Technical Specifications Invertec V350-PRO CETilting Power Cord ConnectionStacking Input and Grounding ConnectionsTIG Module K930-2 Remote Control of InvertecUndercarriage Mountings Parallel Operation Quick Disconnect PlugsVolt Meter Operational Features and ControlsOperation Output ControlThermal Hidden Middle Control Panel Process Set Up PanelWeld Mode Select CONTROL-REMOTE , LocalRemote Control of the Output CON- Trol and Weld Terminals Lower Case FrontTypes of Remote Output Control TIG modeDesign Features and Advantages Potentiometer ControlLimitations Auxiliary PowerRecommended Processes CE Version K1728-3 AccessoriesField Installed OPTIONS/ACCESSORIES V350-PR0 CEMaintenance Exploding Parts can cause injuryTroubleshooting HOW to USE Troubleshooting GuideContact your local Lincoln Authorized Field Service Facility Troubleshooting CPU Displays Description Scrolling dash Diagrams Remote Control AdaptersK867 Plug to LN-7 Connection Diagram K867 Plug to LN-25 Connection Diagram K867 Universal Adapter / Invertec Connection Diagram K876 Adapter to LN-25 Connection Diagram K864 Adapter to LN-7 & Remote Control Connection Diagram Wiring Diagram Invertec V350-PRO CE Dimension Print Page Need Welding Training? How To Read Shop DrawingsNew Lessons in Arc Welding Basic CoursePrecaucion Warnung