| OPERATION |
| ||
|
|
|
|
|
•The Arc Control regulates the relative Slope of the process. Slope dynamically controls the force the arc has to penetrate an open root. At the minimum setting, Arc Control is very soft and is similar to the Stick Soft mode. At the maximum setting, the slope is reduced, the OCV is reduced, and the operator has full control off the arc force required to pene- trate an open root joint. For vertical down, open root pipe welding applications, the recommended setting is between 8 and 10.
•During welding, a boost circuit increases the avail- able voltage to minimize pop outs. The boost circuit is independent of the OCV and only operates when an arc is lit.
TIG GTAW: The TIG mode features continuous con- trol from 5 to 425 amps. The TIG mode can be run in either the TIG touch start or high frequency assisted start mode.
•The Hot Start control selects the starting mode desired. A setting of less than 5, the TIG lift start mode is selected. The OCV is controlled below 10v and the short circuit "TIG touch" current is main- tained at 25 amps independent of the preset current. When the tungsten is lifted, an arc is initiated and the output is regulated at the preset value. Hot start set- tings between 0 and 5 regulate the arc initiation cur- rent. A setting of 5 results in the most positive arc ini- tiation. A setting of 0 reduces hot start.
•Hot Start settings between 5 and 10, select high fre- quency assisted starting TIG mode. In this range, the OCV of the machine is controlled between 50 and 70 volts. If using the Lincoln
•The Arc Control is not used in the TIG mode.
•The Hot Start control is not used in the
•The Arc Control regulates pinch effect. At the mini- mum setting
•The Hot Start control is not used in the
•The Arc Control regulates pinch effect. At the mini- mum setting
8.HOT START and ARC CONTROL features have different functions depending on the welding Mode that is active. Each feature is described under the welding mode heading. (See Item 6 for specified
Mode Operation)
LOWER CASE FRONT
The output studs, line switch and remote connector are located on the lower case front.
9. Both STUDS contain
•The Negative stud is configured to accept the pass through gas system.
10. The
11.The METER POLARITY switch is located above the output connectors. The switch provides a work connection for wire feeder voltmeters. Place the switch in the position of the electrode polarity indi- cated by the decal. The switch does not change the welding polarity.
12.
REMOTE CONTROL of the OUTPUT CON- TROL and WELD TERMINALS
The Invertec
CV modes
•The remote will default to the
•If a remote control is connected or is not connect- ed to any of the amphenols the WELD TERMINAL control will default to REMOTE.