| INSTALLATION |
| ||
|
|
|
|
|
LN-10 Connection Instructions
•Turn the Invertec power switch "off".
•Connect the K1505 control cable from the
•Connect the electrode cable to the output terminal of polarity required by the electrode. Connect the work lead to the other terminal.
•Set the meter polarity switch on the front of the Invertec to coincide with wire feeder polarity used.
•See the
LN-742 Connection Instructions
•Turn the Invertec power switch "off"
•Either a K591 or a K593 Input cable assembly is required to connect the
•Connect the control cable from the
•Connect the electrode cable to the output terminal of the polarity required by electrode. Connect the work lead to the other terminal.
•Set the meter polarity switch on the front of the Invertec to coincide with wire feeder polarity used. The wire feeder will now display the welding volt- age.
•If a remote control such as K857 is to be used with the
Cobramatic Connection Instructions
•Turn the Invertec power switch "off"
•Connect the control cable from the Cobramatic to the 24/42 VAC
•Connect the electrode cable to the output terminal of the polarity required by electrode. Connect the work lead to the other terminal.
•Set the meter polarity switch on the front of the Invertec to coincide with wire feeder polarity used.
•If a remote control such as K857 is to be used with the Cobramatic, the remote can be connected directly to the 6pin amphenol on the front of the Invertec or use a K864 adapter to connect the cobramatic and the remote to the 24/42VAC
TIG MODULE K930-2
The TIG Module connects to the “CE” version with a
CONNECTION OF WIRE FEEDERS TO
REMOTE CONTROL OF INVERTEC
Remote Control K857, Hand Amptrol K963 and Foot Amptrol K870.
UNDERCARRIAGE MOUNTINGS
MOUNTING HOLE LOCATIONS
NOTE: MOUNTING SCREWS CAN NOT PROTRUDE MORE THAN 0.5 INCHES INSIDE THE MACHINE.
3.50 |
10.00
11.84 |
| 8/00 |
|
M19527