A-3

INSTALLATION

A-3

FIGURE A.1 — Dual Voltage Machine Input Connections

50/60 HZ

3.The 208/230 volt 50/60 Hz model POWER MIG is shipped with a 7 ft.(2.1m). input cable and plug connected to the welder.

4.Using the instructions in Figure A.2, have a quali- fied electrician connect a receptacle (Customer Supplied) or cable to the input power lines and the system ground per the U.S. National Electrical Code and any applicable local codes. See “Technical Specifications” at the beginning of this chapter for proper wire sizes. For long runs over 100 feet, larger copper wires should be used. Fuse the two hot lines with super lag type fuses as shown in the following diagram. The center contact in the receptacle is for the grounding connection. A green wire in the input cable connects this contact to the frame of the welder. This ensures proper grounding of the welder frame when the welder plug is inserted into a grounded receptacle.

OUTPUT POLARITY CONNECTIONS

The welder, as shipped from the factory, is connected for electrode positive (+) polarity. This is the normal polarity for GMA welding.

If negative (–) polarity is required, interchange the connection of the two cables located in the wire drive compartment near the front panel. The electrode cable, which is attached to the wire drive, is to be con- nected to the negative (–) labeled terminal and the work lead, which is attached to the work clamp, is to be connected to the positive (+) labeled terminal.

FIGURE A.2 — Receptacle Diagram

CONNECT TO A SYSTEM

GROUNDING WIRE. SEE

THE UNITED STATES

NATIONAL ELECTRICAL

CODE AND/OR LOCAL

CODES FOR OTHER

DETAILS AND MEANS FOR

PROPER GROUNDING.

CONNECT TO HOT WIRES

OF A THREE-WIRE, SINGLE

PHASE SYSTEM.

POWER MIG 215

Image 11
Contents Power MIG California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionSûreté Pour Soudage a LʼArc Précautions DE SûretéThank You Master Table of Contents for ALL Sections Master Table of Contents for ALL Sections Technical Specifications Power MIG InstallationLocation Safety PrecautionsUncrating the Power MIG Input POWER, Grounding and Connection DiagramsFigure A.1 Dual Voltage Machine Input Connections Output Polarity ConnectionsCylinder may explode if damaged GUN and Cable InstallationAuxiliary Power Receptacles Shielding GASWear eye, ear and body protec- tion OperationRecommended Processes and Equipment Wire Drive RollWire Size Conversion Parts Product DescriptionTo Start the Welder Procedure for Changing Drive and Idle Roll SetsWire Reel Loading READI-REELS, Spools or Coils Idle Roll Pressure Setting Feeding Wire ElectrodeFigure B.2b Making a WeldInput Line Voltage Variations Avoiding Wire Feeding ProblemsWire Feed Overload Protection FAN ControlAccessories Accessories Maintenance Table D.1 Liner Removal and REPLACE- MentDescription English Metric Size GUN Handle DisassemblyHOW to USE Troubleshooting Guide TroubleshootingOutput Problems Feeding Problems GAS Flow Problems Wiring Diagrams Enhanced Diagram M19231 Dimension PrintPower MIG Power MIG Precaucion Warnung