Lincoln Electric 215 manual Installation, Technical Specifications Power MIG

Page 9

A-1

INSTALLATION

A-1

TECHNICAL SPECIFICATIONS – POWER MIG 215

INPUT – SINGLE PHASE ONLY

Standard Voltage/Phase/Frequency

208/230/1/50/60 Hz

Duty Cycle 30% 40% 60%

Welding Current Range

30 – 250Amps

Input Current @ 170 Amp Rated Output (With 115V receptacle loaded to 15A)

39/35 Amps

RATED OUTPUT

Amps

215Amps

190Amps

170Amps

OUTPUT

Maximum Open Circuit Voltage

35 Volts

Input Current @ 215 Amp Rated Output (With 115V receptacle loaded to 15A)

45/41 Amps

Volts at Rated Amperes

22Volts

23Volts

24Volts

Welding Voltage Range

13.5-24 Volts

RECOMMENDED INPUT WIRE AND FUSE SIZES

 

 

 

 

 

 

 

 

 

 

 

 

Input Ampere

 

75°C Copper Wire

 

75°C Copper Wire

Input Voltage/

 

Fuse or Breaker

 

in Conduit

 

in Conduit

 

 

Rating On

 

AWG (IEC) Sizes

 

AWG (IEC) Sizes

Frequency (Hz)

 

Size (Super Lag)

 

Nameplate

 

(For lengths

 

(For lengths

 

 

 

up to 100 ft.)

 

exceeding 100 ft.)

208/50/60

 

60

 

45A

 

10 (6 mm2)

 

8 (10 mm2)

230/50/60

 

60

 

41A

 

10 (6 mm2)

 

8 (10 mm2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: Use #10 AWG Grounding Wire

 

 

 

 

 

 

 

 

 

 

 

WIRE SPEED RANGE

 

 

Wire Speed

50 – 700 IPM (1.27 – 17.8 m/minute)

 

 

PHYSICAL DIMENSIONS

 

 

Height

Width

 

Depth

Weight

31.79 in

18.88 in

 

38.78 in

210 Ibs

808 mm

480 mm

 

985 mm

95 kg

 

 

 

 

 

 

 

 

 

TEMPERATURE RANGES

OPERATING TEMPERATURE RANGE

-4°F to 104°F(-20°C to +40°C)

STORAGE TEMPERATURE RANGE

-40°F to 185°F(-40°C to +40°C)

POWER MIG 215

Image 9
Contents Power MIG California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionSûreté Pour Soudage a LʼArc Précautions DE Sûreté Thank You Master Table of Contents for ALL Sections Master Table of Contents for ALL Sections Technical Specifications Power MIG InstallationUncrating the Power MIG Safety PrecautionsInput POWER, Grounding and Connection Diagrams LocationFigure A.1 Dual Voltage Machine Input Connections Output Polarity ConnectionsAuxiliary Power Receptacles GUN and Cable InstallationShielding GAS Cylinder may explode if damagedWear eye, ear and body protec- tion OperationWire Size Conversion Parts Wire Drive RollProduct Description Recommended Processes and EquipmentProcedure for Changing Drive and Idle Roll Sets Wire Reel Loading READI-REELS, Spools or CoilsTo Start the Welder Idle Roll Pressure Setting Feeding Wire ElectrodeFigure B.2b Making a WeldWire Feed Overload Protection Avoiding Wire Feeding ProblemsFAN Control Input Line Voltage VariationsAccessories Accessories Maintenance Table D.1 Liner Removal and REPLACE- MentDescription English Metric Size GUN Handle DisassemblyHOW to USE Troubleshooting Guide TroubleshootingOutput Problems Feeding Problems GAS Flow Problems Wiring Diagrams Enhanced Diagram M19231 Dimension PrintPower MIG Power MIG Precaucion Warnung