Friedrich SQ10, SQ06, SQ05, SQ08 Timer Scheduler Control Block, $OoExwwrqDfwlrqLvEorfnhg

Page 16

AUTO FAN 79F

SET POINT

FRR147

The display returns to normal once the settings are saved.

Timer - Scheduler Control Block

AUTO FAN 79F

SET POINT

SCHEDULE

FRR148

,IWKHXQLWLVRSHUDWLQJLQWKH7,0(5RU6&+('8/(PRGHDQGWKHQ\RX

SUHVVDQ\EXWWRQH[FHSWWKH button, the Timer icon begins to EOLQN$OOEXWWRQDFWLRQLVEORFNHG

AUTO FAN 79F

SET POINT

SCHEDULE

FRR149

The Timer LFRQVWRSVEOLQNLQJDIWHUVHFRQGV<RXPXVWWXUQWKHDFWLYH 7LPHURU6FKHGXOHPRGH2))EHIRUHPDNLQJFKDQJHV2QFHWKHFKDQJHV

are made, press the button to re-activate Timer or Schedule mode.

,IWKHXQLWLVRSHUDWLQJLQWKH7,0(5RU6&+('8/(PRGHDQGWKHQ\RX

SUHVVDQ\EXWWRQH[FHSWWKH button, the Timer icon begins to blink.

AUTO FAN 79F

SET POINT

FRR150

$OOEXWWRQDFWLRQLVEORFNHG

AUTO FAN 79F

SET POINT

SCHEDULE

 

FRR151

The Timer LFRQVWRSVEOLQNLQJDIWHUVHFRQGV<RXPXVWWXUQWKHDFWLYH 7LPHURU6FKHGXOHPRGH2))EHIRUHPDNLQJFKDQJHV2QFHWKHFKDQJHV

are made, press the button to re-activate Timer or Schedule mode.

AUTO FAN 79F

SET POINT

FRR152

Schedule ON Scenarios

SCHEDULE

FRR153

The display shows a normal system.

,IWKH6FKHGXOHIXQFWLRQLVWXUQHG21GXULQJQRUPDORSHUDWLRQWKH SCHEDULE

and Timer icons illuminates. The control system immediately runs the current period schedule parameters.

AUTO FAN 79F

SET POINT

FRR154

The display shows a normal system.



Image 16
Contents RoomAirConditioners Register your air conditioner Table of Contents Safety Precautions Your safety and the safety of others are very importantUnpacking Instructions Test the power cord Make sure the wiring is adequate for your unitDo not use an extension cord Standard Filter Cleaning / Installation Instructions Premium Carbon Filter Installation InstructionsFAN only FAN Mode Control Panel OperationKühl Control Options See FigureControl Panel Operation Instructions RIRSHUDWLRQAuto FAN No Cooling Demand Auto FAN Cooling DemandPoint Timer ScheduleIcon illuminates ºF ºC Select DIM FunctionAlerts Lock Control PanelTimer/Schedule Select External Control Status7KHFRQWUROV\VWHPKDVWKUHH7LPHU6FKHGXOHIXQFWLRQV Programming section of this manualDisplay returns to normal once the settings are saved Modify the Timer Function Timer Start TimeTimer Stop Time Timer Scheduler Control Block $OOEXWWRQDFWLRQLVEORFNHGSchedule on Scenarios Display shows a normal systemDisplay shows the unit in Schedule mode Timer on ScenariosScheduler OFF Scenarios Timer icon turns off. The display shows a normal system Timer OFF ScenariosState Power Button Turns remote and unit on and off Remote Control OperationRemote Effectiveness FAN Auto FAN Mode Continuous Read this FIRST! Electrical Requirements Installation InstructionsDLUÀRZSRVLWLRQLQJ Recommended tools required for installation not included Item no Description QTYZLQGRZVWRRODVVKRZQLQLJXUH6HFWLRQ$$ Standard Window InstallationCut/Sever If chassis seal gasket is not installed, the operation EwrcsExcessive Weight Hazard Cord Routing Change Unplug unitFactory Setting with LEFT-SIDE Thru-the-wall Installation Hpryh the shell channel from the top of the cabinet See ,Place the cabinet in the framed opening CabinetSolid Masonry Construction Final Inspection & Start-up Checklist This is a warm weather applianceCondensation is normal FrostingService and Assistance Routine MaintenanceAvailable Accessories Troubleshooting Tips \FOHV2Q$QG2II7RRUHTXHQWO\8QLW5XQV7RR0XFK VLHGXQLWSODWHDUHERWKDJHQF\FHUWL¿HG Addendum Schedule Table with Energy Saving ValuesRoom AIR Conditioners Limited Warranty 9300100100
Related manuals
Manual 108 pages 3.28 Kb

SQ08, SQ05, SQ06, SQ10 specifications

Friedrich is a renowned name in the HVAC industry, known for its innovative solutions in cooling and heating technologies. Among its impressive lineup, the SQ series, consisting of models SQ10, SQ06, SQ05, and SQ08, stands out for their robust features and advanced performance.

One of the defining characteristics of the SQ series is its energy efficiency. Each model is designed to optimize energy use, allowing for significant cost savings while reducing the environmental impact. This is primarily achieved through the incorporation of advanced inverter technology, which adjusts the compressor speed according to cooling or heating demand, maintaining a comfortable indoor climate without excessive energy consumption.

The SQ series units are equipped with high-performing compressors that provide rapid cooling and heating capabilities. This means that users can expect fast temperature adjustments, ensuring a comfortable environment even during extreme weather conditions. Moreover, the noise levels of these units have been engineered to remain low, offering whisper-quiet operation that does not disrupt daily activities.

Control and convenience are also paramount in the SQ series. The units feature smart technologies that allow for remote operation through mobile applications. This means homeowners can adjust temperatures, set schedules, and monitor their energy usage from anywhere, adding a layer of convenience to the user experience. The user-friendly interface and intuitive controls further enhance accessibility.

Durability and reliability are core elements of the SQ models. Constructed with high-quality materials and components, these units are built to withstand the rigors of daily use. The units also come with comprehensive warranties, offering peace of mind to users regarding long-term performance.

In summary, Friedrich's SQ10, SQ06, SQ05, and SQ08 units showcase a blend of energy efficiency, advanced technology, and user-centric features. With their quiet operation, fast temperature adjustments, and smart connectivity, they provide an ideal solution for reliable heating and cooling needs in residential or commercial spaces. The robust design ensures longevity, making Friedrich a trusted choice in climate control solutions.