Friedrich SQ06, SQ10, SQ05, SQ08 operation manual Timer on Scenarios, Scheduler OFF Scenarios

Page 17

AUTO FAN 79F

SET POINT

SCHEDULE

FRR155

,IWKH6FKHGXOHIXQFWLRQLVWXUQHG21GXULQJD6NLSSHULRGWKH SCHEDULE

and Timer icons illuminates. The control system immediately runs the previous (non-skip) period schedule parameters.

Timer ON Scenarios

AUTO FAN 79F

SET POINT

FRR156

The display shows a normal system.

AUTO FAN 79F

SET POINT

FRR159

,IWKH7LPHUIXQFWLRQLVWXUQHG21GXULQJWKH21WLPHWKH7LPHU icon illuminates. The control system continues to run.

Scheduler OFF Scenarios

AUTO FAN 79F

SET POINT

SCHEDULE

 

FRR160

The display shows the unit in Schedule mode.

AUTO FAN 79F

SET POINT

FRR157

,I WKH 7LPHU IXQFWLRQ LV WXUQHG 21 GXULQJ WKH 2II WLPH WKH icon LOOXPLQDWHV7KHFRQWUROV\VWHPLPPHGLDWHO\WXUQVWKHXQLW2))

AUTO FAN 79F

SET POINT

FRR158

The display shows a normal system.

FRR161

,IWKH6FKHGXOHIXQFWLRQLVWXUQHG2))GXULQJDQDFWLYHVWDWH QRWRII WKH Timer and SCHEDULE icons turn off. The control stays in the current state. The display shows a normal system.

SCHEDULE

FRR162

7KHGLVSOD\VKRZVWKHXQLWLQ6FKHGXOHPRGHGXULQJDQLQDFWLYH 2))  period.



Image 17
Contents RoomAirConditioners Register your air conditioner Table of Contents Your safety and the safety of others are very important Safety PrecautionsUnpacking Instructions Do not use an extension cord Make sure the wiring is adequate for your unitTest the power cord Premium Carbon Filter Installation Instructions Standard Filter Cleaning / Installation InstructionsControl Panel Operation FAN only FAN ModeSee Figure Kühl Control OptionsRIRSHUDWLRQ Control Panel Operation InstructionsAuto FAN No Cooling Demand Auto FAN Cooling DemandIcon illuminates Timer SchedulePoint DIM Function ºF ºC SelectLock Control Panel AlertsExternal Control Status Timer/Schedule Select7KHFRQWUROV\VWHPKDVWKUHH7LPHU6FKHGXOHIXQFWLRQV Programming section of this manualTimer Stop Time Modify the Timer Function Timer Start TimeDisplay returns to normal once the settings are saved $OOEXWWRQDFWLRQLVEORFNHG Timer Scheduler Control BlockSchedule on Scenarios Display shows a normal systemScheduler OFF Scenarios Timer on ScenariosDisplay shows the unit in Schedule mode State Timer OFF ScenariosTimer icon turns off. The display shows a normal system Remote Effectiveness Remote Control OperationPower Button Turns remote and unit on and off FAN Auto FAN Mode Continuous DLUÀRZSRVLWLRQLQJ Installation InstructionsRead this FIRST! Electrical Requirements Item no Description QTY Recommended tools required for installation not includedCut/Sever Standard Window InstallationZLQGRZVWRRODVVKRZQLQLJXUH6HFWLRQ$$ Ewrcs If chassis seal gasket is not installed, the operationExcessive Weight Hazard Unplug unit Cord Routing ChangeFactory Setting with LEFT-SIDE Hpryh the shell channel from the top of the cabinet See , Thru-the-wall InstallationPlace the cabinet in the framed opening CabinetSolid Masonry Construction This is a warm weather appliance Final Inspection & Start-up ChecklistCondensation is normal FrostingAvailable Accessories Routine MaintenanceService and Assistance \FOHV2Q$QG2II7RRUHTXHQWO\ Troubleshooting TipsSODWHDUHERWKDJHQF\FHUWL¿HG VLHGXQLW8QLW5XQV7RR0XFK Schedule Table with Energy Saving Values AddendumRoom AIR Conditioners Limited Warranty 9300100100
Related manuals
Manual 108 pages 3.28 Kb

SQ08, SQ05, SQ06, SQ10 specifications

Friedrich is a renowned name in the HVAC industry, known for its innovative solutions in cooling and heating technologies. Among its impressive lineup, the SQ series, consisting of models SQ10, SQ06, SQ05, and SQ08, stands out for their robust features and advanced performance.

One of the defining characteristics of the SQ series is its energy efficiency. Each model is designed to optimize energy use, allowing for significant cost savings while reducing the environmental impact. This is primarily achieved through the incorporation of advanced inverter technology, which adjusts the compressor speed according to cooling or heating demand, maintaining a comfortable indoor climate without excessive energy consumption.

The SQ series units are equipped with high-performing compressors that provide rapid cooling and heating capabilities. This means that users can expect fast temperature adjustments, ensuring a comfortable environment even during extreme weather conditions. Moreover, the noise levels of these units have been engineered to remain low, offering whisper-quiet operation that does not disrupt daily activities.

Control and convenience are also paramount in the SQ series. The units feature smart technologies that allow for remote operation through mobile applications. This means homeowners can adjust temperatures, set schedules, and monitor their energy usage from anywhere, adding a layer of convenience to the user experience. The user-friendly interface and intuitive controls further enhance accessibility.

Durability and reliability are core elements of the SQ models. Constructed with high-quality materials and components, these units are built to withstand the rigors of daily use. The units also come with comprehensive warranties, offering peace of mind to users regarding long-term performance.

In summary, Friedrich's SQ10, SQ06, SQ05, and SQ08 units showcase a blend of energy efficiency, advanced technology, and user-centric features. With their quiet operation, fast temperature adjustments, and smart connectivity, they provide an ideal solution for reliable heating and cooling needs in residential or commercial spaces. The robust design ensures longevity, making Friedrich a trusted choice in climate control solutions.