Friedrich SQ06, SQ10, SQ05, SQ08 operation manual Excessive Weight Hazard

Page 25

Figure 16

 

 

 

 

 

 

 

GRA

Y FOAM

 

 

 

 

GASKET

 

 

 

 

 

(ARTSULISE

 

 

TION

 

 

ITEM#5OPN

AGE2)

CHASISEAL

 

 

 

 

 

GASKET

 

 

 

 

 

OT PRVENT

 

AIRLEAKS

AROUND

THE

AIR

CDTIONER, INSE

 

TRT

HEWFOAMHITE

 

 

GASKET

(,6#ITEMP

AGE2)BTWEN

 

 

THE

AIRCDTIONER

 

AND TABINETCHE

 

 

 

 

 

 

 

FR08

Figure 17

 

NDEIVORPOTCHES

 

FORALETRIC

 

CTIXEORD

 

SCREW

, #8x1SPILH/2”

HEAD(ARTSULISE

TION

I,TEM#2P

AGE2)

2QUIRED(ACHE1 SIDE)

 

 

FR089

CAUTION

Excessive Weight Hazard

Use two or more people when installing your air conditioner.

Failure to do so can result in back or other injury.

CAUTION

Cut/Sever

Although great care has been taken to minimize sharp edges in the construction of your unit, use gloves or other hand protection when handling unit

Failure to do so can result in minor to moderate personal injury.

25

Image 25
Contents RoomAirConditioners Register your air conditioner Table of Contents Your safety and the safety of others are very important Safety PrecautionsUnpacking Instructions Test the power cord Make sure the wiring is adequate for your unitDo not use an extension cord Premium Carbon Filter Installation Instructions Standard Filter Cleaning / Installation InstructionsControl Panel Operation FAN only FAN ModeSee Figure Kühl Control OptionsRIRSHUDWLRQ Control Panel Operation InstructionsAuto FAN No Cooling Demand Auto FAN Cooling DemandPoint Timer ScheduleIcon illuminates DIM Function ºF ºC SelectLock Control Panel AlertsExternal Control Status Timer/Schedule Select7KHFRQWUROV\VWHPKDVWKUHH7LPHU6FKHGXOHIXQFWLRQV Programming section of this manualDisplay returns to normal once the settings are saved Modify the Timer Function Timer Start TimeTimer Stop Time $OOEXWWRQDFWLRQLVEORFNHG Timer Scheduler Control BlockSchedule on Scenarios Display shows a normal systemDisplay shows the unit in Schedule mode Timer on ScenariosScheduler OFF Scenarios Timer icon turns off. The display shows a normal system Timer OFF ScenariosState Power Button Turns remote and unit on and off Remote Control OperationRemote Effectiveness FAN Auto FAN Mode Continuous Read this FIRST! Electrical Requirements Installation InstructionsDLUÀRZSRVLWLRQLQJ Item no Description QTY Recommended tools required for installation not includedZLQGRZVWRRODVVKRZQLQLJXUH6HFWLRQ$$ Standard Window InstallationCut/Sever Ewrcs If chassis seal gasket is not installed, the operationExcessive Weight Hazard Unplug unit Cord Routing ChangeFactory Setting with LEFT-SIDE Hpryh the shell channel from the top of the cabinet See , Thru-the-wall InstallationPlace the cabinet in the framed opening CabinetSolid Masonry Construction This is a warm weather appliance Final Inspection & Start-up ChecklistCondensation is normal FrostingService and Assistance Routine MaintenanceAvailable Accessories \FOHV2Q$QG2II7RRUHTXHQWO\ Troubleshooting Tips8QLW5XQV7RR0XFK VLHGXQLWSODWHDUHERWKDJHQF\FHUWL¿HG Schedule Table with Energy Saving Values AddendumRoom AIR Conditioners Limited Warranty 9300100100
Related manuals
Manual 108 pages 3.28 Kb

SQ08, SQ05, SQ06, SQ10 specifications

Friedrich is a renowned name in the HVAC industry, known for its innovative solutions in cooling and heating technologies. Among its impressive lineup, the SQ series, consisting of models SQ10, SQ06, SQ05, and SQ08, stands out for their robust features and advanced performance.

One of the defining characteristics of the SQ series is its energy efficiency. Each model is designed to optimize energy use, allowing for significant cost savings while reducing the environmental impact. This is primarily achieved through the incorporation of advanced inverter technology, which adjusts the compressor speed according to cooling or heating demand, maintaining a comfortable indoor climate without excessive energy consumption.

The SQ series units are equipped with high-performing compressors that provide rapid cooling and heating capabilities. This means that users can expect fast temperature adjustments, ensuring a comfortable environment even during extreme weather conditions. Moreover, the noise levels of these units have been engineered to remain low, offering whisper-quiet operation that does not disrupt daily activities.

Control and convenience are also paramount in the SQ series. The units feature smart technologies that allow for remote operation through mobile applications. This means homeowners can adjust temperatures, set schedules, and monitor their energy usage from anywhere, adding a layer of convenience to the user experience. The user-friendly interface and intuitive controls further enhance accessibility.

Durability and reliability are core elements of the SQ models. Constructed with high-quality materials and components, these units are built to withstand the rigors of daily use. The units also come with comprehensive warranties, offering peace of mind to users regarding long-term performance.

In summary, Friedrich's SQ10, SQ06, SQ05, and SQ08 units showcase a blend of energy efficiency, advanced technology, and user-centric features. With their quiet operation, fast temperature adjustments, and smart connectivity, they provide an ideal solution for reliable heating and cooling needs in residential or commercial spaces. The robust design ensures longevity, making Friedrich a trusted choice in climate control solutions.