Dust Collection System (Optional)

Installation

Transport the shipping container to the installation site. Unpack the dust collection system and check for damage. Contact the carrier if damage is found. Open the installation kit (refer to Optional Accessories in the parts listing for installation kits). Install the cover and debris collection drawer if removed. Slip a hose clamp over the 3-inch vacuum hose. Slip the hose on the inlet duct. Move the clamp over the duct to secure the hose.

Repeat the procedure to connect the hose to the outlet duct on the grinding machine.

Filter

Check for accumulation of debris. Replace the filter at intervals that you determine are appropriate for your shop environment and machine utilization.

Drawer Seal

Check the drawer seal periodically and replace if damaged or missing. Keep the seal in good condition to help maintain collection system efficiency.

Electrical Connection

Refer to the Dust Collection System Wiring Diagram for wiring information. Connection to electrical power should be made by a qualified electrician. Observe local electrical codes when connecting the machine.

Operation

The dust collection system motor is started by setting the toggle switch on the motor to the ON position. Set the switch to OFF to shut down the dust collection system.

Maintenance

WARNING:

ON/OFF switch on motor at rear of dust collection system

Removable cover – remove for interior cleaning/access to impeller

Second Inlet Duct on this side

28

·MAKE SURE YOU DISCONNECT THE ELECTRI- CAL POWER TO THE DUST COLLECTION SYS- TEM BEFORE PERFORMING MAINTENANCE. FAILURE TO DO SO MAY RESULT IN INJURY TO THE OPERATOR AND/OR MAINTENANCE PERSONNEL.

·DO NOT OPERATE THE DUST COLLECTION SYSTEM WITH THE COVER REMOVED. INJURY TO FINGERS AND HANDS FROM THE FAN BLADES, AND INGESTION OF LOOSE FITTING CLOTHING INTO THE AIR INLET WITH RESULTANT INJURY IS ALSO POSSIBLE.

Cleaning

Outlet filter at rear removes fine debris from outlet air stream

Inlet Duct – Connect 3 inch hose - secure with clamp

Chip Drawer - Pull to Open

Periodically dispose of accumulated chips and debris from the chip drawer. Use a brush to loosen debris from internal surfaces. Use a vacuum cleaner to clean up the loosened debris.

Figure 1: Dust Collector Assembled View

Image 28
Contents Disc, Belt, and Combination Disc/Belt Sanders Warranty and Service Table of Contents Machine and Manual Overview General Specifications Disc Sander Belt Sander Disc/Belt SanderGeneral Machinery Cautions General Machinery WarningsSafety Requirements for Abrasive Sanding Machines Wire SizesGeneral Electrical Cautions Adjusting the Belt Sander Arm Operating InstructionsAdjusting the Disc Sander Table Use of the Miter GaugeMaintenance Belt ReplacementInstalling Abrasive Discs Track Mechanism MaintenanceReplacing the V-Belt Rotating the machine casting to remove the disc guard bolts Machine Setup Basic SetupDisc Table Miter Parallelism Adjustment Disc Table Angle AdjustmentDisc Table Gap Adjustment Belt Table Miter Slot Parallelism Adjustment Belt Table Angle AdjustmentAdjusting or Replacing the Platen Electrical Single Phase Electrical Hookup Three Phase Electrical HookupMotor Rotation Voltage ConversionTroubleshooting Fault Probable cause Suggested remedyJIC Packages Replacement Parts Standard 1 phase and 3 phase machinesExploded View Model 4200A Belt and Disc Sander Assembly Parts Listing Model 4200A Belt and Disc Sander Assembly Ref # Description QtyExploded View Model 4300A Belt Sander Assembly Parts Listing Model 4300A Belt Sander Exploded View Model 4400A Disc Sander Assembly Parts Listing Model 4400A Disc Sander Assembly Exploded View Base Assembly All Models Installation MaintenanceElectrical Connection OperationDisassembly Exploded View Model 5511885 Dust Collection System Parts Listing Model 5511885 Dust Collection System Wiring Information Dust Collection SystemWMH Tool Group