Troubleshooting – Machine Fault & Operating Problems
Problem | Probable Cause | Solution | |
|
|
| |
| Electrical power supply | Check: the phases; the cables; the plug; the socket. | |
| Also check that the motor connections are in place. | ||
|
| ||
|
|
| |
| Transformer | Check that the voltages are present both on the input | |
| and output. Otherwise replace. | ||
|
| ||
|
|
| |
|
| Check that the phases in it are present both on the | |
| Contactor | input and output, that it is not jammed, that it closes | |
| when powered and that it is not causing short circuits. | ||
|
| ||
Spindle motor will not |
| Change if any of these problems are found. | |
|
| ||
turn |
| Make sure it is closed, ie check that the phases are | |
|
| present in input and output that it is not causing short | |
| Thermal relay | circuits and responds when the reset coil is closed. If it | |
| has tripped to protect the motor, check the amperage | ||
|
| ||
|
| setting, reset, and check the motor. Change if | |
|
| necessary. | |
|
|
| |
|
| Check that it has not burnt out, that it turns freely and | |
| Motor | that there is no moisture in the connection terminal | |
|
| board box. The winding can be rewound or replaced. | |
|
|
| |
| Cutting Vise Valve | Make sure the valve is operating correctly, replace if | |
For SX version: Cutting | necessary. | ||
| |||
|
| ||
vise will not close or will | Compressed air supply hose | Check that air is not leaking through the cylinder seals. | |
not open |
|
| |
Vise cylinder | Check the hose is not kinked or blocked. Remove the | ||
| |||
| obstruction. Replace cylinder or cylinder seals | ||
|
| ||
|
|
|
Parts
Ordering Replacement Parts
To order parts or reach our service department, call
19