Friedrich H)A09K25, V(E service manual Serial Number Identification Guide

Page 4

 

Model Identification Guide

 

 

 

 

 

 

 

 

 

 

 

 

MODEL NUMBER

 

V

E

A

24

K

50

RT

A

 

SERIES

 

 

 

 

 

 

 

 

 

ENGINEERING CODE

V=Vertical Series

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E=Cooling with or without electric heat

 

 

 

 

 

 

OPTIONS

H=Heat Pump

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RT = Standard Remote Operation

DESIGN SERIES

 

 

 

 

 

 

 

 

 

SP = Seacoast Protected

A = 32" and 47" Cabinet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOMINAL CAPACITY

 

 

 

 

 

 

 

 

 

ELECTRIC HEATER SIZE

A-Series (Btu/h)

 

 

 

 

 

 

 

 

 

A-Series

09 = 9,000

 

 

 

 

 

 

 

 

 

00 = No electric heat

12 = 12,000

 

 

 

 

 

 

 

 

 

25 = 2.5 KW

18 = 18,000

 

 

 

 

 

 

 

 

 

34 = 3.4 KW

24 = 24,000

 

 

 

 

 

 

 

 

 

50 = 5.0 KW

 

 

 

 

 

 

 

 

 

 

75 = 7.5 KW

VOLTAGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 = 10 KW

K = 208/230V-1Ph-60Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Serial Number Identification Guide

 

SERIAL NUMBER

 

L

 

K

A

V

00001

 

Decade Manufactured

 

 

 

 

 

 

PRODUCTION RUN NUMBER

 

J = 9 K = Not Used

 

 

 

 

 

 

 

L = 0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PRODUCT LINE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YEAR MANUFACTURED

 

 

 

 

 

R = RAC

 

A = 1

E = 5

J = 9

 

 

 

 

 

 

P = PTAC

 

B = 2

F = 6

K = 0

 

 

 

 

 

 

E = EAC

 

C = 3

G = 7

 

 

 

 

 

 

 

V = VPAK

 

D = 4

H = 8

 

 

 

 

 

 

 

H = SPLIT

 

 

 

 

 

 

 

 

 

MONTH MANUFACTURED

 

 

 

 

 

 

 

A = Jan

D = Apr

G = Jul

 

K = Oct

 

 

 

 

B = Feb

E = May

H = Aug

 

L = Nov

 

 

 

 

C = Mar

F = Jun

J = Sep

 

M = Dec

 

 

 

4

Image 4
Contents VE,HA09K25 VE,HA09K34 VE,HA12K25 VE,HA12K34VE,HA18K25 VE,HA18K34 VE,HA24K25 VE,HA24K34Table of Contents Introduction Serial Number Identification Guide VERT-I-PAKH Suffix Chassis Specifications VERT-I-PAKE & G Suffix Chassis Specifications VERT-I-PAKA D Suffix Chassis Specifications Refrigeration Assembly Sequence of OperationElectrical Supply Supply CircuitSupply Voltage Control Low VoltageRoom Thermostats Heat AnticipatorsTypical Electrical & Thermostat Wiring Diagrams Typical Electrical & Thermostat Wiring Diagrams Suffix For 208 Volt Models only Move the White Wire AS Shown below Indoor Blower Airflow Condenser Fan MotorsBlower Wheel Inspection CoolingChecking Approximate Airflow Checking External Static PressureElectric Heat Strips Ductwork Preparation Explanation of chartsRefrigerant Charging Method Of Charging Undercharged Refrigerant SystemsOvercharged Refrigerant Systems Restricted Refrigerant SystemsTesting Coil Metering Device Capillary Tube SystemsReversing Valve Description/Operation Electrical Circuit and CoilChecking Reversing Valve Touch Test in Heating/Cooling CycleCompressor Checks From Electrical ShockSingle Phase Resistance Test Recommended Procedure for Compressor ReplacementCapacitors Capacitor ConnectionsElectric Heat Switch Operation Electric Heat Switch Check OutWiring Diagram Index VHA09K25RTG Suffix only Suffix only Suffix only Page Page Page Page Page Page Page Page Page Electrical Troubleshooting Chart Cooling TON Electrical Troubleshooting Chart Cooling Troubleshooting Chart Cooling Electrical Troubleshooting Chart Heat Pump Page Use Factory Certified Parts