Friedrich EQ08M11, XQ06M10, XQ05M10 How to operate the Friedrich room air conditioner XQ models

Page 10

How to operate the Friedrich room air conditioner (XQ models)

To start unit

If your air conditioner is installed and plugged into a proper receptacle, it is ready to go. The first time the unit is started, the compressor will delay for three minutes. See Automatic Component Protection on the following page.

1Touch the Power button once. The unit will automatically be in Cool mode with the temperature set at 75°F (24°C) and the fan speed at F1, the sleep setting.

To set mode of operation

When you rst turn the unit on, it will be in the Cool mode (light on), with constant fan.

2Touch the Mode button once to activate the MoneySaver® (light on).

MONEYSAVER® is a feature that cycles the fan with the compressor so that the fan does not run all the time. This saves energy and improves dehumidication. Or you may prefer constant fan for more air movement (to return to constant fan, touch the Mode button two more times).

In order to run the fan by itself, do the following:

3Continuing from MoneySaver® mode (light on), touch the Modebutton once to activate the FAN ONLY feature (light on).

The FAN ONLY setting will circulate air in the room without the com- pressor coming on.

To adjust temperature

4Use the Mode button to select either the COOL or MoneySaver® function

5COOLER – Touch the button to lower the room air temperature.

6WARMER – Touch the button to raise the room air temperature.

7Press both the and buttons at the same time to switch the temperature readout from Fahrenheit (°F) to Celsius (°C).

Repeat step 7 to switch from °C back to °F.

To adjust fan speed

8Touch the FanSpeed button to see the current setting. Touch it again to change speed. F1 is the lowest setting (SLEEP SETTING / LOW), F2 is MEDIUM, and F3 is HIGH.

To activate Smart Fan

9There is a fourth option, SF, when selecting the fan speed. This is the SMART FAN function. SMART FAN DOES NOT OPERATE IN CONJUCTION WITH THE FAN ONLY MODE.

8

9

2

3

4

1

Figure 5

8

9

2

3

4

1

Figure 3

 

 

 

 

 

 

PM

 

 

 

 

X Star

PM

 

 

 

 

 

 

 

 

 

 

 

Power

 

 

 

 

 

 

Power

 

 

 

 

 

Cool

 

 

Fan

 

 

 

Cool

®

 

Speed

 

Mode

MoneySaver

 

 

 

 

 

Fan

 

Mode

Money Saver®

 

Speed

 

Fan Only

 

 

 

 

 

 

Fan Only

 

 

 

 

 

 

Clock

 

 

Timer

Set

Clock

 

 

StartTime

 

 

Timer

 

Hour

Start Time

 

 

 

Set

 

 

On/Off

 

Hour

Stop Time

Temp/Hour

 

Stop Time

 

 

 

 

Temp/Hour

 

 

 

 

 

 

 

 

 

 

5

6

13

10

11

12

 

5

6

13

10

11

12

 

7

 

7

To set the hour clock

10Touch the Set Hour button to see the current setting (clock light comes on). The number that is displayed is the approximate time

(hour only). Use the and buttons to change the settings. BE SURE TO SET A.M. AND P.M. ACCORDINGLY. (P.M. is indicated by a red light in the upper left corner of the display).

To set the timer

NOTE: Set the HOUR CLOCK before attempting to set timer functions.

You can set the START and STOP times a minimum of one hour apart, and a maximum of twenty-three hours apart.

11After setting the time, press the Set Hour button once (Start light

comes on). Use the and buttons to select the time that the unit will START.

12After selecting the START time, press the SetHourbutton once more

(Stop light comes on). Use the and buttons to select the time that the unit will STOP. After selecting the stopping time, press the Set Hour button once.

13Press the Timer On/Off button (light turns on) to activate the timer function. To deactivate this function, press the Timer On/Off button once again (light turns off). Once the on and off times have been selected, they will remain in memory and cycle daily until changed.

NOTE: If the unit is unplugged or the power is interrupted, the HOUR must be reset or the Timer On/Off will not function when desired.

Automatic component protection

Smart Fan will adjust the fan speed automatically to maintain the desired comfort level. For example, if the outside doors in your home are opened for an extended period of time, or more people enter a room, Smart Fan may adjust to a higher fan speed to compensate for the increased heat load. This keeps you from having to adjust the fan speed on your own.

Your unit is equipped with Automatic Component Protection. To protect the compressor of the unit, there is a three minute start delay if you turn the unit off or if power is interrupted. The fan operation will not be affected. Also, if you switch from Cool mode to Fan Only, and switch back to Cool mode, there is a three minute delay before the compressor comes back on.

9

Image 10
Contents Volt XQ05M10*, XQ06M10*, XQ08M10*, XQ10M10 Volt EQ08M11Table Of Contents Important Safety Information Your safety and the safety of others are very importantRefrigeration System Hazards Introduction Property Damage Hazards5th Digit Model Series / Year Introduced Unit Identification6th Digit Voltage 00001Performance Data Electric Shock Hazard Electrical DataFire Hazard Electrical Shock Hazard How to operate the Friedrich room air conditioner XQ models How to use the remote control XQ models Electronic Control Sequence of Operation Electrical Components Functional Component DefinitionsMechanical Components Hermetic ComponentsError Code Listings Components TestingTesting the Electronic Control Boards for XQ Models Activating Test ModeThermostat Adjustment EQ08 System Control Switch TestEQ08 System Control Switch Test TestCapacitor Connections CapacitorsCapacitor Check with Capacitor Analyzer FAN MotorHeating Element Testing the Heating Element Electric Shock HazardDrain PAN Valve Refrigeration Sequence of Operation 410A Sealed System Repair Considerations Refrigeration system under high pressureEquipment Must be Capable 410A Sealed Refrigeration System RepairsEquipment Required Risk of Electric ShockBurn Hazard Method Of Charging / RepairsFreeze Hazard Undercharged Refrigerant Systems Overcharged Refrigerant SystemsRestricted Refrigerant System Compressor Checks Single Phase Resistance Test Ground TestHigh Temperatures Compressor ReplacementRecommended procedure for compressor replacement Explosion HazardRotary Compressor Special Troubleshooting and Service Routine Maintenance Front Cover Sleeve / DrainClearances Room AIR Conditioner Unit Performance Test Data Sheet Date Model SerialGeneral Troubleshooting Tips Unit does not operateDo not try to operate your air conditioner Cooling only Room AIR Conditioners Troubleshooting Tips Replace fuse, reset breaker. If repeats, check Fused separately Allowing discharge air to short Heat / Cool only Room AIR Conditioners Troubleshooting Tips Electronic Control Cool only Models Last character may vary Aham PUB. NO. RAC-1 Heat Gain from Quantity Factors Cooling Load Estimate FormDAY Following is an example using the heat load form Heat Load FormWindows & Doors Area, sq. ft Infiltration Windows & Doors AVGRoom AIR Conditioners Limited Warranty Technical Support Contact Information Page Friedrich AIR Conditioning CO

XQ08M10, XQ10M10, XQ05M10, XQ06M10, EQ08M11 specifications

Friedrich offers a range of innovative air conditioning units designed to provide superior comfort and energy efficiency. Among its lineup, the XQ06M10, EQ08M11, XQ05M10, XQ08M10, and XQ10M10 models stand out due to their advanced technologies and user-friendly features.

The XQ series, with models like XQ06M10 and XQ05M10, is renowned for its sleek design and exceptional performance in cooling and heating environments. These models utilize a highly efficient compressor system that reduces energy consumption while maintaining optimal temperature control. The XQ06M10, for example, is designed for medium-sized rooms, featuring a cooling capacity that caters well to residential and small office settings.

On the other hand, the EQ08M11 model is known for its enhanced energy efficiency compared to traditional units, thanks to its inverter technology. This feature allows the compressor to adjust its speed according to the cooling demand, resulting in lower energy costs and a quieter operation. The EQ08M11 is also equipped with a multi-stage filtration system, improving indoor air quality by capturing dust, allergens, and pollutants.

The XQ08M10 and XQ10M10 cater to larger spaces, with their respective higher cooling capacities making them suitable for bigger living areas or small commercial settings. Both models boast an easy-to-use digital control panel, which requires minimal effort to adjust settings. Additionally, they include a programmable timer feature, allowing users to automate operation according to their daily schedules, further enhancing energy savings.

All these models showcase Friedrich’s commitment to durability and reliability, built with high-grade materials designed to withstand varying temperatures and humidity levels. The XQ series is compact, facilitating easy installation without compromising performance.

In summary, the Friedrich XQ06M10, EQ08M11, XQ05M10, XQ08M10, and XQ10M10 models combine cutting-edge technology with practicality, ensuring an efficient and enjoyable indoor climate. With features aimed at energy efficiency, ease of use, and effective air filtration, these units represent a smart investment for anyone looking to enhance their living or working environment.