Friedrich XQ05M10, EQ08M11, XQ06M10, XQ10M10, XQ08M10 service manual Performance Data

Page 7

PERFORMANCE DATA

*

 

 

 

 

 

 

 

 

 

 

 

EVAP. AIR TEMP. DEG. F

 

 

 

 

OPERATING PRESSURES

ELECTRICAL RATINGS

R-410A

 

COOLING

CONDENSER

 

 

 

 

REF.

 

 

 

Discharge Temp

Suction Temp

Super Heat

Sub-Cooling

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PERFORMANCE DATA**

Discharge Air

Temp.

TEMPERATURE DEG. F

Suction

Discharge

Amps Cool

Amps Heat

Locked Rotor

Charge in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Drop F.

 

 

 

 

 

Amps

OZ.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XQ05M10*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

57

23

117

133

60

5

19

157

410

4.5

 

24.0

27.0

Chassis

XQ06M10*

54

26

120

152

63

12

18

150

410

4.9

 

25.0

21.0

XQ08M10

*

51

29

119

160

63

13

25

138

420

6.3

 

32.0

25.5

Q-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XQ10M10*

47

33

131

176

59

12

32

132

490

9.8

 

57.0

24.0

 

EQ08M11*

49

31

120

162

60

14

27

133

420

7.0

7.6

32.0

25.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Due to continuing research in new energy-saving technology, performance data and 8th and 9th character are subject to change without notice.

 

* Rating Conditions: 80 degrees F, room air temp. & 50% relative humidity, with 95 degree F, outside air temp & 40% relative humidity, all systems use R410A.

BREAKER FUSE

Voltage

60 Hertz Amps

11515

11515

11515

11515

11515

 

 

 

 

 

 

 

 

 

Energy

Estimated

 

Room Side

 

 

 

 

 

 

 

 

 

 

 

Yearly

Moisture

Air

Net

 

Cooling

Heating

Volts

Cooling

Cooling

Heating

Heating

 

Ratio

Operating

Removal

Circulation

Weight

Model

Capacity Btu

Capacity Btu

Rated

Amps

Watts

Amps

Watts

COP

EER

Cost

Pints/HR

CFM

Sleeve Lbs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XStar ®

XQ05M10*

5500

115

4.5

491

 

11.2

$39

1.0

170

Q

72

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XQ06M10*

6000

115

4.9

500

 

12.0

1.0

175

Q

72

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XQ08M10*

7500

115

6.9

701

 

10.7

$56

1.7

175

Q

71

 

 

 

 

 

 

 

 

9.8

$56

2.5

180

Q

71

XQ10M10*

9500

115

9.0

970

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XStar ® Electric Heat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EQ08M11*

7500

4000

115

6.3

701

11.2

1290

2.8

10.7

$56

1.9

175

Q

72

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R-410A

As an ENERGY STAR® partner, Friedrich Air Conditioning Co. has determined that the selected ENERGY STAR® () models meet the ENERGY STAR®

Estimated yearly operating cost based on a 2007 national average electricity cost of 10.65 cents per kWh.

† The estimated yearly operating cost of this model was not available at the time the range was published.

All models use

environmentally friendly R-410A refrigerant.

Installation Information / Sleeve Dimensions

 

 

 

Depth

Shell Depth to

Minimum

Minimum

 

 

 

with Front

Louvers

Extension

Extension

 

 

 

 

 

Sleeve

Height

Width

 

 

Into Room*

Outside*

 

 

 

 

 

 

 

Q

14"

19 ¾"

21 3/8"

8 ½"

5 ½"

10 ¾"

 

Thru-the-wall Installation

Window Width

Finished Hole

Minimum** Maximum Height Width Max. Depth

22"

42"

14 ¼"

20"

8 ½”

* Minimum extensions when mounted in a window.

** Minimum widths achieved using one side curtain assembly as opposed to both in a standard installation.

Circuit Rating/ Breaker

 

 

Circuit Rating

Plug

 

 

 

 

 

 

 

Breaker or

Face

Power Cord

Wall Outlet

 

Model

T-D Fuse

(NEMA#)

Length (ft.)

Appearance

 

 

 

 

 

 

 

 

 

 

XQ05M10*, XQ06M10*,

 

 

7

 

 

 

 

 

XQ08M10*, XQ10M10*

 

 

 

 

 

 

 

 

EQ08M11*

125V - 15A

5 - 15P

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FRONT

Window Mounting Kits

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heat/Cool Models

Kit No.

 

 

 

 

 

 

 

EQ08M11*

WIKQ

 

 

 

 

 

 

Friedrich heat/cool models include accessories for thru-the-wall installation only. Window mounting requires use of optional accessory kit as listed above.

(C)

(B)

SIDE VIEW

6

Image 7
Contents Volt EQ08M11 Volt XQ05M10*, XQ06M10*, XQ08M10*, XQ10M10Table Of Contents Your safety and the safety of others are very important Important Safety InformationRefrigeration System Hazards Property Damage Hazards Introduction00001 Unit Identification6th Digit Voltage 5th Digit Model Series / Year IntroducedPerformance Data Electric Shock Hazard Electrical DataFire Hazard Electrical Shock Hazard How to operate the Friedrich room air conditioner XQ models How to use the remote control XQ models Electronic Control Sequence of Operation Hermetic Components Functional Component DefinitionsMechanical Components Electrical ComponentsActivating Test Mode Components TestingTesting the Electronic Control Boards for XQ Models Error Code ListingsTest EQ08 System Control Switch TestEQ08 System Control Switch Test Thermostat AdjustmentFAN Motor CapacitorsCapacitor Check with Capacitor Analyzer Capacitor ConnectionsHeating Element Testing the Heating Element Electric Shock HazardDrain PAN Valve Refrigeration Sequence of Operation Refrigeration system under high pressure 410A Sealed System Repair ConsiderationsRisk of Electric Shock 410A Sealed Refrigeration System RepairsEquipment Required Equipment Must be CapableBurn Hazard Method Of Charging / RepairsFreeze Hazard Overcharged Refrigerant Systems Undercharged Refrigerant SystemsRestricted Refrigerant System Compressor Checks Ground Test Single Phase Resistance TestExplosion Hazard Compressor ReplacementRecommended procedure for compressor replacement High TemperaturesRotary Compressor Special Troubleshooting and Service Routine Maintenance Front Cover Sleeve / DrainClearances Date Model Serial Room AIR Conditioner Unit Performance Test Data SheetUnit does not operate General Troubleshooting TipsDo not try to operate your air conditioner Cooling only Room AIR Conditioners Troubleshooting Tips Replace fuse, reset breaker. If repeats, check Fused separately Allowing discharge air to short Heat / Cool only Room AIR Conditioners Troubleshooting Tips Electronic Control Cool only Models Last character may vary Aham PUB. NO. RAC-1 Heat Gain from Quantity Factors Cooling Load Estimate FormDAY Heat Load Form Following is an example using the heat load formInfiltration Windows & Doors AVG Windows & Doors Area, sq. ftRoom AIR Conditioners Limited Warranty Technical Support Contact Information Page Friedrich AIR Conditioning CO

XQ08M10, XQ10M10, XQ05M10, XQ06M10, EQ08M11 specifications

Friedrich offers a range of innovative air conditioning units designed to provide superior comfort and energy efficiency. Among its lineup, the XQ06M10, EQ08M11, XQ05M10, XQ08M10, and XQ10M10 models stand out due to their advanced technologies and user-friendly features.

The XQ series, with models like XQ06M10 and XQ05M10, is renowned for its sleek design and exceptional performance in cooling and heating environments. These models utilize a highly efficient compressor system that reduces energy consumption while maintaining optimal temperature control. The XQ06M10, for example, is designed for medium-sized rooms, featuring a cooling capacity that caters well to residential and small office settings.

On the other hand, the EQ08M11 model is known for its enhanced energy efficiency compared to traditional units, thanks to its inverter technology. This feature allows the compressor to adjust its speed according to the cooling demand, resulting in lower energy costs and a quieter operation. The EQ08M11 is also equipped with a multi-stage filtration system, improving indoor air quality by capturing dust, allergens, and pollutants.

The XQ08M10 and XQ10M10 cater to larger spaces, with their respective higher cooling capacities making them suitable for bigger living areas or small commercial settings. Both models boast an easy-to-use digital control panel, which requires minimal effort to adjust settings. Additionally, they include a programmable timer feature, allowing users to automate operation according to their daily schedules, further enhancing energy savings.

All these models showcase Friedrich’s commitment to durability and reliability, built with high-grade materials designed to withstand varying temperatures and humidity levels. The XQ series is compact, facilitating easy installation without compromising performance.

In summary, the Friedrich XQ06M10, EQ08M11, XQ05M10, XQ08M10, and XQ10M10 models combine cutting-edge technology with practicality, ensuring an efficient and enjoyable indoor climate. With features aimed at energy efficiency, ease of use, and effective air filtration, these units represent a smart investment for anyone looking to enhance their living or working environment.