INSTALLATION | ||
|
|
|
5.REMOVING THE FUME TUBE ASSEMBLY (See figure A.7)
Figure A.7
•Loosen locking collar (counter clockwise,
• Slide the fume tube out of the gun handle.
• Slide the fume tube off of the gun tube.
CONSUMABLE PARTS
Contact tips | See Table A.3 |
Gas diffuser assembly | |
Gas nozzle assembly, 5/8 inch opening | |
Fume collection nozzles | See Figure A.6 |
CONNECT THE GUN TO THE WIRE FEEDER
1.Make sure that the gun locking knob is loosened. Insert the gun into the gun conductor block and tighten the gun locking knob.
2.Make the gas connection from the feeder to the gun (if required).
3.Plug the trigger harness into the gunʼs
CONNECT THE GUN TO THE FUME COLLECTION SYSTEM
1.Speed setting for Lincoln Miniflex system: “High” is preferred for maximum fume collection.
2.Automatic / Manual setting (where available): Set to “Manual” mode so that fume collection system will continue running after welding. This ensures maxi- mum cooling of the gun. Fume collection system or gate valve to the gun may be shut off or closed after the gun has cooled for 10 minutes since the last
weld.
• Fume tube removed.