Lincoln Electric 550, 350 manual Connect the GUN to the Wire Feeder

Page 13

A-6

INSTALLATION

A-6

 

 

 

5.REMOVING THE FUME TUBE ASSEMBLY (See figure A.7)

Figure A.7

Loosen locking collar (counter clockwise, right-hand threads) on fume tube. Gas diffuser may remain in place.

• Slide the fume tube out of the gun handle.

• Slide the fume tube off of the gun tube.

CONSUMABLE PARTS

Contact tips

See Table A.3

Gas diffuser assembly

KP2747-1

Gas nozzle assembly, 5/8 inch opening

KP2743-2-62R

Fume collection nozzles

See Figure A.6

CONNECT THE GUN TO THE WIRE FEEDER

1.Make sure that the gun locking knob is loosened. Insert the gun into the gun conductor block and tighten the gun locking knob.

2.Make the gas connection from the feeder to the gun (if required).

3.Plug the trigger harness into the gunʼs Y-connector. Plug the trigger harnessʼ connector into the recep- tacle on the front of the feeder.

CONNECT THE GUN TO THE FUME COLLECTION SYSTEM

1.Speed setting for Lincoln Miniflex system: “High” is preferred for maximum fume collection.

2.Automatic / Manual setting (where available): Set to “Manual” mode so that fume collection system will continue running after welding. This ensures maxi- mum cooling of the gun. Fume collection system or gate valve to the gun may be shut off or closed after the gun has cooled for 10 minutes since the last

weld.

• Fume tube removed.

MAGNUM™ PRO 350 and 550 FUME GUNS

Image 13
Contents IM990 California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionSûreté Pour Soudage a LʼArc Précautions DE SûretéThank You Table of Contents Technical Specifications Magnum PRO Fume Guns InstallationMagnum PRO 350 and 550 Fume Guns Feeder END Figure A.2, Items 1 thru Unpacking the Fume GUNFeeder END Figure A.4, Items 1 thru Compatibility of Welding Machines and Wire Feeders Safety PrecautionsPrepare the Welding Machine and Wire Feeder as follows Preparing the Fume GUN for WeldingKit No. for Gun Model Select and Install a Wire Feeder Connection K KITWire Diameter 350 amp 550 amp Select and Install GUN Consumable PartsKP Nos. for Gun Model Removing the Fume Tube Assembly See figure A.7 Connect the GUN to the Wire FeederConnect the GUN to the Fume Collection System Product Description OperationTrigger Position See Figure B.1 Selecting or ChangingWelding Also See Installation Section Load Specified Wire Into the GUNPrepare the Fume GUN for Make the WeldAccessories or Options AccessoriesRoutine Cleaning Inspections MaintenanceGAS Diffuser Replacement Liner Assembly Cleaning or ReplacementGun Handle, See Figure D.1 Trigger and Accessory Switch Lead RoutingsTrigger Assembly Replacement GUN Tube ReplacementGUN Cable Assembly Replacement Assembly Cleaning or ReplacementMaintenance HOW to USE Troubleshooting Guide TroubleshootingProblems Path Unkinked wire emerges Poor fume extraction Possible Areas Recommended Symptoms Possible Recommended Symptoms Cause Course of Action Magnum PRO 350 and 550 Fume Guns Magnum PRO 350 and 550 Fume Guns Precaucion Aviso DE