Lincoln Electric 11572 manual Design FEATuRES, Rated OuTPuT DuTY Cycle, Control Panel

Page 9

A-2

INSTALLATION

A-2

GENERAL DESCRIPTION

The Classic® 300D Perkins is a heavy duty, engine driven, DC arc welding power source, capable of providing constant current output for stick welding or DC TIG welding. This welder is wound with all copper coils, rated at 300 amps/32 Volts, and provides other Classic® features such as improved door latches and stainless hinges. With the addi-

tion of the optional K623-1 Wire Feed Module, the Classic® 300D Perkins will provide constant voltage output for running the LN-7, LN-23P, or LN-25 wire feeders. (The Wire Feed Module is factory installed on the K1643-8). The optional K924-5 Remote Control Kit, provides a remote con- trol rheostat for remote fine current and open circuit voltage adjustment. See Section C for description.

The Classic® 300D Perkins has an Electronic Engine Protection System. In the event of sudden low oil pressure or high coolant temperature, the engine immediately shuts down. The Classic® 300D Perkins has a current range of

40-350 DC amps with output ratings as follows:

These units are also capable of providing 3 KVA of 115/230 volts of 60 cycle AC auxiliary power.

The Classic® 300D Perkins uses the Perkins 404D-22 industrial water-cooled diesel engine.

RATED OuTPuT

DuTY CYCLE

 

 

 

 

250A

@

30V

100%

300A

@

32V

60%

 

 

 

 

DESIGN FEATuRES

Control Panel

Both the engine and the welder controls are located on one recessed panel at the exciter end of the machine. The welder controls consist of a five step “Current Range Selector” switch and a “Fine Current Adjustment” rheostat. The welder is equipped with a “Start” button, an “Ignition” switch, an “Idler” control switch, and a “Glow Plug” button for easier cold weather starting.

The control panel also contains an engine temperature gauge, a battery charging ammeter, an oil pressure gauge, for auxiliary power consists of one 20 amp, 120VAC (5-20R) duplex receptacle with GFCI protection and one 15 amp, 250VAC (6-15R) receptacle, protected by 2 pole, 15 Amp breaker.

All Copper Windings - For long life and dependable operation.

Engine Idler - The Classic® 300D Perkins is equipped with an electronic automatic engine idler. It automatically increases and decreases engine speed when starting and stopping welding or using auxiliary power.

A built-in time delay permits changing electrodes before the engine slows to its low idle speed.

The “Idler” control switch on the panel locks the idler in high idle position when desired.

Auxiliary Power - 3.0 KVA of nominal 115/230V, 60Hz, AC. Output voltage is maintained within ± 10% at all loads up to rated capacity. (See Optional Features Section C for Power Plug Kit.)

GFCI Module - Protects the 20 amp, 120V duplex recepta- cle. See the Maintenance Section for detailed information on testing and resetting of the GFCI Module.

120 V DuPLEx RECEPTACLE AND GFCI MODuLE

A GFCI Module protects the 120V auxiliary power receptacle.

A GFCI (Ground Fault Circuit Interrupter) is a device to protect against electric shock should a piece of defective equipment connected to it develop a ground fault. If this situation should occur, the GFCI module will trip, removing voltage from the out- put of the receptacle. If a GFCI module is tripped see the MAINTENANCE section for detailed information on testing and resetting it. A GFCI module should be properly tested at least once every month.

The 120 V auxiliary power receptacle should only be used with three wire grounded type plugs or approved double insulated tools with two wire plugs. The current rating of any plug used with the system must be at least equal to the current capacity of the associated receptacle.

Welder Enclosure - The complete welder is rubber mount- ed on a rugged steel “C” channel base.

The output terminals are placed at the side of the machines so that they are protected by the door. The output terminals are labeled (+) and (-).

Cranking System - A 12 volt electric starter is standard.

Air Cleaner - Heavy duty two stage dry type.

Muffler - A muffler and stainless steel exhaust outlet elbow are standard.

Engine hour Meter - A meter to record hours of operation.

Engine Protection - The system shuts the engine down in the event of sudden low oil pressure or high coolant temper- ature. A warning light on the control panel will indicate such a fault. To reset the engine for restarting, turn the ignition switch off then on.

Oil Drain Valve - A ball valve, hose and clamp are stan- dard.

Remote Control - The Remote / Local Switch and Receptacle are standard.

CLASSIC® 300D PERKINS

Image 9
Contents Classic 300 D Perkins California Proposition 65 Warnings SafetyElectric ShOCK can kill ARC Rays can burnFuMES and Gases can be dangerous Welding and CuTTING Sparks can Cause fire or explosion Cylinder may explode if damagedIii Sûreté Pour Soudage a L’Arc PRÉCAuTIONS DE Sûreté On-Line Product Registration Please Examine Carton and Equipment For Damage ImmediatelyTAbLE of Contents TEChNICAL Specifications Classic 300D Perkins InstallationRated OuTPuT DuTY Cycle Design FEATuRESControl Panel DuPLEx Receptacle and Gfci MODuLETrailer see Optional FEATuRES MAChINE GROuNDINGLift bAIL VEhICLE MOuNTING Polarity Control and CAbLE SIzESFuEL BATTERY ChARGING 5INSTALLATIONA-5To prevent ExPLOSION when To prevent Electrical Damage whenStarting ThE Classic 300D Perkins 404D-22 Diesel Engine OperationCold WEAThER Starting Stopping ThE EngineEngine bREAK-IN Welder OperationIdler Operation Optional FEATuRES Field Installed AccessoriesWire Feed Module K623-1 Magnum 250 Innershield Gun for LN-23P K355-10Gun tube for PipeWelding KP1909-1 Safety PRECAuTIONS MaintenanceGeneral INSTRuCTIONS BEARINGSVent Screw Priming Lever PuRGING AIR from FuEL System Perkins 404D-22 EngineMaintenance Gfci MODuLE Testing and Resetting PROCEDuRE HOW to uSE TROubLEShOOTING GuIDE TROubLEShOOTINGPRObLEMS POSSIbLE CAuSECOuRSE of Action Open Closed Electronic Idler TROubLEShOOTING GuIDEDefective -- Will Not Close Auxiliary Power Load is Turned onContact your local Lincoln Authorized Field Service FacilityWater passage. Flush the system Ing on Faulty light wiring Enhanced Diagram DiagramsDiagrams Skid 24.00 40.94 37.1218.50 23.00Classic 300D Perkins Classic 300D Perkins Atenção Atenção