PURGING & PRIMING

PURGING AND PRIMING THE PUMP

PURGING AND PRIMING THE SPRAY HOSE

1.

Place a full container of

 

 

paint underneath the

Suction

 

suction tube.

tube

2.

Secure the return tube

Return

 

into a waste container.

 

tube

3. Turn the pressure control dial to maximum pressure

(+).

1.Unlock the spray gun and turn PRIME/SPRAY knob to PRIME.

Your spray tip SHOULD NOT be attached to your spray gun when purging your spray hose.

2.Trigger and HOLD the spray gun into a waste container.

3.While holding the trigger, switch the pump ON (l).

PRIME

SPRAY

4. Turn the PRIME/SPRAY

PRIME

SPRAY

 

 

knob to PRIME.

 

 

5.Plug in the sprayer, and move the ON/OFF switch to the ON position.

l

The unit will begin to draw paint up the suction tube, into the pump, and out the return tube. Let the unit cycle long enough to remove test fluid from the pump, or until paint is coming from the return tube.

6.Switch the pump to OFF (O).

7.Remove the return tube from the waste container and place it in its operating position above the container of paint. Use the metal clip to bind the two hoses together.

Your sprayer is now purged. Move to Purging and Priming the Spray Hose.

4. While holding the trigger,

PRIME

turn the PRIME/SPRAY

 

knob to SPRAY. Hold the

 

trigger until all air, water, or

 

solvent is purged from the

 

spray hose and paint is

SPRAY

flowing freely (read

 

warnings below).

 

WARNING

Keep hands clear from fluid stream.

WARNING

Using a metal container, ground

the gun by holding it against the edge of the container while

flushing. Failure to do so may lead to a static electric discharge which may cause a fire.

If the PRIME/SPRAY knob is still

on SPRAY, there will be high pressure in the hose and spray gun until the PRIME/SPRAY knob is turned to PRIME.

5.Release trigger, turn the

PRIME/SPRAY knob to

PRIME and turn pump PRIME SPRAYo OFF (O).

6.Trigger the gun into the waste container once more to be sure that no pressure is left in the hose.

7.Lock the spray gun off.

8.Thread the spray tip guard assembly onto the gun. Tighten by hand.

Begin

 

to achieve

 

tightening

 

the desired

the tip at

 

spray angle

this angle

 

when tight.

Your hose is now purged and primed. You are ready to paint.

© 2002 Wagner Spray Tech - All rights reserved.

7

Customer Service: 800-686-8525

English

 

 

 

 

Image 7
Contents Specifications Table of ContentsHigh Performance Airless Sprayer Safety Information Read ALL Safety Grounding Instructions Important Electrical InformationComponents Components and DescriptionControls and Functions Locking and Unlocking the Spray GUN SETUP--ASSEMBLING the SprayerBefore YOU Prime the Sprayer Pressure Relief ProcedureBefore YOU Begin Plugging in the SprayerYour hose is now purged and primed. You are ready to paint Purging & PrimingPractice SprayingSpraying Technique Unclogging the Spray TIP Spraying TroubleshootingCleaning the Spray GUN Filter Cleaning the Suction SET ScreenMove on to Cleaning the Spray Gun, next CleanupCleaning the Suction SET Move on to Cleaning the Suction SetTrigger Guard Cleaning the Spray GUN Filter and TIP AssemblyGX-08/10 FilterStartup StoragePreparing the Sprayer for LONG- Term Storage ShutdownExtended Maintenance MaintenanceAccessories Daily MaintenanceDisassembly of the Fluid Section Fluid Section Seal Replacement InstructionsAssembly of the Fluid Section Problem TroubleshootingSuction SET Dispositif ’ASPIRATION Juego DE Succió N Parts List Liste DE PIÈ CES Lista DE PiezasArticulo Article N de piè ce Description Quantity0296262 02962910296343 0347706Article N de piè ce Description Quantité Articulo Pieza# Descripció n CantidadTelephone Wagner Spray Tech CorporationFernbrook Lane Minneapolis, Minnesota